1. Introduction
This is a single phase meter with communication RS485 and RF. Protocol for RS485 is DTL645.
Meter with inside relay support for connect and disconnect functions.
2. Features and Technical Parameters
2.1 Features
●LCD display show voltage, current, power, and kWh.
●Measuring total energy consumption, support both active and reactive energy measurement.
●Meter with inside relay 80A which support on and off function through communication program
●Meter support both RF and RS485 communication, protocol for RS485 is DTL645, protocol for
RF is self defined.
RS485 communication:
baud rate 9600 (fixed), eight data bits, even parity check, one stop bit
RF communication:
baud rate 9600 (fixed), eight data bits, without parity check, one stop bit
●RF only used for communication with IHD (in home display)
●address for in home display and meter should corresponding and same
●It can received meter returned data when press ”SEND” on IHD
●
IHD will ask meter every 1 minute for get data in case of with power supply
2.2 Technical Parameters
Voltage:
230V
Current:
10(80) A
Impulse constant:
1600imp/kWh
Display:
LCD 6+2
Operating temperature
:
-20—45
℃
Storage temperature
:
-25—70
℃
relative humidity
:
≤75%
Frequency
:
50Hz
Accuracy class
:
1.0 s
Starting current
:
0.4%Ib(1.0s)
Power consumption
:
Voltage circuit Un
<2W / <10VA @ Un
Current circuit In
<2.5 VA @ (Ib)