3.2 

Installation 

  The  air  filter  regulator  can  be  installed  with  or  without  a  bracket  depending  on  the  field 

conditions. The air filter regulator is used to supply constant air pressure to various devices 

such  as  positioner,  actuator  and  solenoid  valve.  The  product  can  be  installed  using  only 

pneumatic  piping  without  a  separate  bracket.  Before  connecting,  be  sure  to  blow  out  all 

piping to prevent impurities from entering in to the product and ensure that it is the right size 

meeting the required capacity. 

  If  you  require  brackets  for  installation,  you  can  check  the  dimensions  mentioned  in  the 

diagram on previous page and make the desired bracket type to suit each models. Below is 

an example of YT-220 with bracket installation. 

 

 

 

 

3.3 

How to Use

 

1)  Before  supplying  air  pressure  to  the  product,  turn  the  adjustment  bolt  counterclockwise 

so that the adjustment spring is not pressed at all. 

2)  Install  a  pressure  gauge  on  the  output  port  (OUT).  This  pressure  gauge  will  show  the 

output pressure that is depressurized from the primary pressure (IN). 

3)  Install pressure gauge and ball valves or other fittings to the outports, and then apply air 

pressure to the primary input port (IN). 

4)  Turn the adjust bolt clockwise, and then the secondary pressure goes up to the set value, 

turn the adjusting nut of the adjusting bolt clockwise to lock it completely to prevent the 

adjust bolt from moving. 

 

 
 
 

Содержание YT-200 Series

Страница 1: ...Air Filter Regulator PRODUCT MANUAL YT 200 205 220 225 Series YT 200 YT 205 YT 220 YT 225 VERSION 1 01 ...

Страница 2: ... Operation Logic 7 2 7 1 YT 200 205 Manual drain type 8 2 7 2 YT 220 225 Manual drain type 9 2 8 Product Dimension 10 2 8 1 YT 200 205 Manual drain type 10 2 8 2 YT 200 205 Auto drain type 10 2 8 3 YT 220 225 Manual drain type 11 2 8 4 YT 220 225 Auto drain type 11 2 9 1 YT 200 205 12 2 9 2 YT 220 225 12 3 Installation 13 3 1 Safety 13 3 2 Installation 14 3 3 How to Use 14 4 Maintenance 15 4 1 Rep...

Страница 3: ...al damages caused by customer s modifying or repairing the product without a prior consultation with Young Tech co Ltd will not be compensated If any alterations or modifications are necessary please contact Young Tech Co Ltd directly Standard type with NBR rubber ambient temperature range option 1 is subject to damage by ozone If you suspect that ozone may be present at the site or if supplied ai...

Страница 4: ...eumatically operating devices 2 2 Main Features and Functions Maintains desirable pressure level regardless of fluctuation of the main supply pressure 5 micron filter filters most particles in the main supply pressure Relief function is available which discharges to the atmosphere if the output pressure is higher than setting pressure By using aluminum or stainless steel body it has high durabilit...

Страница 5: ...ique lot number YEAR Indicates manufactured year AMBIENT TEMP Indicates the allowable ambient temperature for explosion proof MAX SUPPLY Indicates max supply air pressure level ADJUST RANGE Indicates adjusting range of the output pressure AIR CONNECTION Indicates connection thread type Precautions Be careful not to apply volatile solvent hardener of instant adhesive acetone WD 40 etc to the sticke...

Страница 6: ...0 YT 220 YT 205 YT225 Max Supply Pressure 1 7 MPa 17 bar Max Out Pressure 0 42MPa A Type 0 84MPa B Type Air Connection PT NPT 1 4 PT NPT 1 2 NPT 1 4 NPT 1 2 Gauge Connection PT NPT 1 4 PT NPT 1 4 NPT 1 4 NPT 1 4 Ambient Temperature Standard 20 C 70 C 4 F 158 F High 20 C 120 C 4 F 248 F Low 40 C 70 C 40 F 158 F Min Filtering Size 5 micron Housing Material Aluminum Diecasting Stainless Steel 316 Wei...

Страница 7: ... on the secondary port reaches set pressure this pressure is transmitted to the bottom of the diaphragm through the output pressure sensing hole and the set pressure is maintained by balancing the force with the adjusting spring If the pressure on the secondary port is higher than the set pressure the pressure delivered through the output pressure sensing hole pushes up the diaphragm and opens bet...

Страница 8: ...Air Filter Regulator YT 200 205 220 225 series Product Manual Ver 1 01 8 2 7 Parts and Assembly 2 7 1 YT 200 205 Manual drain type ...

Страница 9: ...Air Filter Regulator YT 200 205 220 225 series Product Manual Ver 1 01 9 2 7 2 YT 220 225 Manual drain type ...

Страница 10: ...Air Filter Regulator YT 200 205 220 225 series Product Manual Ver 1 01 10 2 8 Product Dimension 2 8 1 YT 200 205 Manual drain type 2 8 2 YT 200 205 Auto drain type ...

Страница 11: ...Air Filter Regulator YT 200 205 220 225 series Product Manual Ver 1 01 11 2 8 3 YT 220 225 Manual drain type 2 8 4 YT 220 225 Auto drain type ...

Страница 12: ...Air Filter Regulator YT 200 205 220 225 series Product Manual Ver 1 01 12 2 9 Pressure and Flow Characteristics 2 9 1 YT 200 205 2 9 2 YT 220 225 ...

Страница 13: ...he manual Exceeding the specification may result in damage to the product or accident If there is any impact on the product it may cause malfunction or failure so be careful during handling installation and operation For maintenance periodically open the drain plug at the bottom of the product to discharge the condensate Exhaust to the atmosphere are made through a small exhaust hole next to the s...

Страница 14: ...u can check the dimensions mentioned in the diagram on previous page and make the desired bracket type to suit each models Below is an example of YT 220 with bracket installation 3 3 How to Use 1 Before supplying air pressure to the product turn the adjustment bolt counterclockwise so that the adjustment spring is not pressed at all 2 Install a pressure gauge on the output port OUT This pressure g...

Страница 15: ...se the drain plug surely 4 3 Replacing Ass y diaphragm When replacing the ass y diaphragm the main supply pressure to the product must be shut down completely or adjust the pressure level of 1kgf cm2 or below Loosen the nut of the adjust bolt and turn the adjust bolt counterclockwise to completely drop the output pressure to zero Unscrew 6 bolts on spring case assembly in diagonal direction Replac...

Страница 16: ...16 Manufacturer Young Tech Co Ltd 81 Hwanggeum ro 89 Beon gil Yangchon eup Gimpo si Gyeonggi do South Korea 10048 Tel 82 31 986 8545 Fax 82 70 4170 4927 Email ytc sales rotork com Homepage http www ytc co kr Issued 2018 08 28 Copyright Young Tech Co Ltd All Rights Reserved ...