YSMART MPPT10 Скачать руководство пользователя страница 3

YSMART TECHNOLOGY CO.,LTD

website:www.ysmart-tech.com

Phone: 86-755-85232255

Add:No. 30 XinFeng Road,Potoubei Village,Ailian Town,Longgang Dist,Shenzhen 51872,P.R. China

Parameters / Model

MPPT10

MPPT20

MPPT30

MPPT40

Maximum power current

12A

20A

30A

40A

Installation Lin

mm

2

4mm

2

8mm

2

10mm

2

12mm

2

Installation Line(AWG)

10(AWG)

8(AWG)

7(AWG)

6(AWG)

Weight

280g

300g

475g

480

Dimensions

143×89×46

mm

187*97*61

mm

System load loss

13mA

Loop Buck

100mV

Battery float voltage

13.8V

12V system

/27.6V

24V system

Battery

under voltage) protection

10.6V

12V system

/21.2V

24V system

Battery

under voltage) recovery voltage

12.6V

12V system

/25.2V

24V system

Charge mode

MPPT+PWM MODE

Operating Temperature

-10

~60

Storage Temperature

-30

~70

Humidity requirements

≤90

, No condensation

Temperature compensation

-4mV/Cell/

Temperature Probe (built components)

NTC 100K thermistats

Maximum open circuit voltage of the solar panel

18V-24V

12V system

36V-48V

24V system

Solar panels maximum open circuit voltage (V)

48V

6

(Cases) 12V system standard configuration

The peak voltage of the
solar cell panel

Maximum

power voltage (V))

18V-25V

18V-25V

18V-25V

18V-25V

Peak power of solar cell
panel

50W-130W

100W-260W

200W-380W

≤500W

Model

MPPT10

MPPT20

MPPT30

MPPT40

Battery standard voltage

12V

12V

12V

12V

Battery capacity

≥100AH

≥200AH

≥300AH

≥400AH

Installation Lin

mm

2

4mm

2

8mm

2

10mm

2

12mm

2

Installation Line(AWG)

10(AWG)

8(AWG)

7(AWG)

6(AWG)

Отзывы: