![YSI SonTek RiverSurveyor Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/ysi/sontek-riversurveyor/sontek-riversurveyor_system-manual_915336029.webp)
SonTek/YSI Inc
RiverSurveyor System Manual (May 1, 2007)
17
3.1.1. RiverSurveyor “Standard” System
Users with multiple deployment requirements commonly select the
“Standard” RiverSurveyor system (
electronics are self-contained in a robust housing. This system can be
easily deployed in a downward-looking configuration from a moving
vessel for current and river profiling (
), or mounted looking
upwards from the river bottom to profile velocities from a fixed position.
The RiverSurveyor “Standard” system includes:
•
A standard ADP in a pressure-rated aluminum housing with an inter-
nal compass/pitch/roll sensor
•
10-m power and serial communication cable
•
24-volt DC power supply (110/220 VAC input required)
•
RiverSurveyor acquisition and post-processing software (
•
Tool kit
Typical options available for the RiverSurveyor “Standard” system include:
•
•
•
Internal or external battery packs
•
40-inch fiberglass trimaran hulls and integrated radio telemetry
•
Inflatable kayak
Typical operating characteristics and configurations for the RiverSurveyor “Standard” system:
•
Available frequencies: 250 kHz, 500 kHz, 1.0 MHz, 1.5 MHz, 3.0 MHz
•
Lower frequencies allow for “deeper” profiling (see
for comparison)
•
Easily deployed in upward or downward-looking orientations
•
Operates on 12-24 VDC input power
Figure 3-1. RiverSurveyor
"Standard" Systems:
1.5 MHz (left),
250 kHz (right)
Figure 3-2. A 500-kHz RiverSurveyor "Standard" System on the Paraná River in Brazil
Содержание SonTek RiverSurveyor
Страница 2: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 ii ...
Страница 4: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 iv ...
Страница 14: ......
Страница 24: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 12 ...
Страница 26: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 14 ...
Страница 71: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 59 Figure 4 7 Exporting data from ViewADP ...
Страница 74: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 62 ...
Страница 82: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 70 ...
Страница 143: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 131 Figure 7 39 Discharge Measurement Summary ...
Страница 148: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 136 ...
Страница 162: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 150 ...
Страница 166: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 154 ...
Страница 168: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 156 ...
Страница 182: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 170 ...
Страница 184: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 172 Figure F 1 FlowPack Discharge Rating Report ...
Страница 194: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 182 ...