YSI 5200A
13
YSI 5200A
12
Figure 1.1
Preview of User Manual
This manual includes information on installing, configuring, operating, and main-
taining a 5200A system.
Read Chapter 2
“Safety Information”
starting on page 20 before installing or
configuring 5200A systems.
Chapter 3
“Installation”
starting on page 26 provides information on how to in-
stall the 5200A, 5200A components, and peripheral devices. Only
qualified
people
should install a 5200A system. Do not attempt to install or configure this device
if you are not
qualified
to do so. If information is not clear, DO NOT PROCEED
until clarification can be obtained. All wiring involving connections to main power
must be performed by a qualified licensed electrician and must conform to all locally
applicable electrical codes. At times “5X00” will be used in this manual to identify
the entire YSI family of instruments being 5200A, 5400 and 5500D instruments.
Chapter 4
“Configuring 5200A Systems
” starting on page 66 provides information
on menu structure and configuring 5200A instruments. At times “5X00” will be
used in this manual to identify the entire YSI family of instruments being 5200A,
5400 and 5500D instruments.
Introduction
Chapter 5 “
AquaManager”
starting on page 198 provides general information re-
garding the PC software program. The AquaManager program includes an extensive
help system, which contains detailed information that is not provided in this manual.
This icon is used throughout the manual to indicate helpful information for Aqua-
Manager users.
Is used to bring attention to new 5X00 instrument and AquaManager features and
functionality.
Chapter 6 “
Maintenance”
starting on page 208provides information on maintaining
the 5200A system including the monitor and sensor service.
“Notes”
at the end of each manual section provide additional information to help
clarify certain 5200A operations and features.
Appendices include information on Unpacking & Inspection, Troubleshooting,
Menu Maps, Declaration of Conformity, Parts and Accessories, SMS Messaging.
Warranty, Contact Us and Recycling information.
An index is provided starting on page 265.
Product Specifications
To ensure accurate and reliable performance, operate the 5200A system according to
specifications provided in the following tables. Damage and/or incorrect operation
could result if these specifications are not followed.
Product specifications are subject to change without notice. Visit www.ysi.com to
view the most recent product specifications.
Environmental Specifications
Environmental Category
Operating Range
Temperature
-15 to 70˚C (5 to 158˚F)
Enclosure Rating
NEMA 4X (direct exposure to outside conditions),
IP65
Compression Fitting Rating
IP 68/NEMA 6 (liquid tight)
Electrical Safety
IEC compliant*
Other
RoHS compliant
See Appendix 4 Declaration of Conformity
- page 253.
NEW
Introduction