. Specification:
l
Rechargeable accumulator inside, you can use the scale during recharging.
l
Auto zero-setting when switch on the scale.
l
Auto zero-tracing.
l
Switch among weighing, counting, percentum. Function of choosing Weight range
.
l
Power supply: AC 220V (
±
10%) / 50 Hz, 110V/60HZ, DC 6V / 4Ah (Rechargeable
accumulator inside).
l
Working temperature range: 0
~ +40
/
l
Relative humidity:
85 % RH
. Keyboard instruction:
1.
Cali.
To Calibrate the scale when the scale is moved to a different place.
2.
Model
To choose different function model: Weighing, Counting, percentum.
3.
Unit
To choose different unit: kg, lb.
4.
Set
To choose high and low limits range in weighing model.
To sample the weight in counting and percentum model.
5.
Zero
To make the display zero when there’s nothing on the platform but the
display is not zero. Press this key continuously for 2-4 second, the backlight will be
switched on or off.
6.
Tare
To delete the tare.
7.
To input number.
8.
Enter
To make sure.
. Operation:
The scale must to be placed on the stable and flat surface, adjust its four screws carrier pole
to horizontal, if demand, put the special plate, then switch on the power. The scale cannot be used
for a long time under tare state or the function of zero tracing will disappear and the zero will
move.
The scale will go into the weighing model after the beginning display. The signals of “Zero”
and “kg” set. You may press
Model
to choose the three model: weighing, counting, percentum
circularly.
Backlight on/off: Press
Zero
key continuously for 2-4 second, the backlight will be
switched on or off.
Weighing model
Choosing Unit Function: Press
Unit
to choose the unit between “kg” and “lb”. The
corresponding signal sets on display.
Tare Function:
Put the container on the platform. Press
Tare
to make the weight window display “Zero” after
the weight is stable. When the “Tare” signal sets, the weight displays is Net Weight. Remove the
weight, the weight window displays negative. Press
Tare
again, the weight window displays
“Zero”. The “Tare” signal disappears.
Zero Function: You may press
Zero
to make display zero when the zero moved when in
use.(Zero range: <=4%FS, it is invalid under tare state.)
Setting Alarm Function:
1. High limit setting--Press
Set
to display the set weight high limit and the signal “-HH-”
circularly. Press
Enter
to make sure and set the low limit. Press
to set the number. In the
process of inputting the number, you may press
to add 1 on the recent digit. Press
Enter
to make sure of the recent digit and set the next digit. If the digit is the last one you may press
Enter
to set the low limit.