Young 06201 Скачать руководство пользователя страница 3

Page 2

06201-90

 

The Wind Tracker may be mounted from a bulkhead or installed 

in a flush panel by removing the mounting bracket. Panel cutout 

dimensions  are  given  in  the  specifications. An  optional  rack 

mounting panel (Model 06280) and protective enclosure (Model 

06260) are available from your YOUNG supplier.  

2.  Connect  cables  to  terminals.  Refer  to  diagram  on  page 

5. 

 

Selector switch on back panel should be DOWN for normal 

sensor inputs, UP for 4-20 mA inputs or for use with Wind 

Monitor-SE.

3.  Connect GND terminal to suitable earth ground.

4.  Insert power supply plug into power jack, plug into standard 

AC wall outlet.

5.  The Wind Tracker will display a software version number for 

approximately  4  seconds.  It  will  then  begin  to  display  wind 

information. The following information is displayed:

 

• 

Wind Speed

 

• 

Wind Speed Units

 

• 

Maximum Wind Speed or Direction degrees

 

• 

Wind Direction (single orange indicator)

 

• 

Direction Variability (green indicators)

 

• 

WS, WD Alarm Status Indicators (If selected)

 

• 

Data Averaging Indicator (If selected)

6.  Observe the unit for a few minutes to verify that it is operating 

properly. If you wish to change settings (ie: wind speed units), 

this is done easily using the keys on the front panel. 

CHANGING SETTINGS

The Wind Tracker has a SETUP mode that allows you to easily change 

sensor type, wind speed units, averaging time, alarm settings, and 

other functions.

Press and hold 

ENTER

 and 

SELECT

 keys (about 5 seconds). The 

display will briefly flash “SEt uP”, then begin the 

SETUP sequence. 

Change settings with the 

SELECT

 key. Press the 

ENTER

 key to save 

a setting and move to the next step. Abbreviations in the left and right 

display windows identify each function and the available selections.

DISPLAY 

 

SETUP FUNCTION

LEFT 

RIGHT

 

 

Input / Sensor Type

InP  

LDi

 

Line Driver 4-20mA input

 

 

03

 

Wind Sentry

 

04

 

Wind Monitor-Jr

 

05

 

Wind Monitor

 

05A

 

Wind Monitor-AQ

 

09

 

Wind Monitor-SE

 

SEr

 

Serial input for remote display only

 

 

If SEr is selected, SETUP sequence ends 

here.

 

 

Wind Speed Units

SPd 

unt

 

Press SELECT to change units, ENTER to 

proceed.

 

 

Display Averaging

dSP 

no

 

No averaging. Instantaneous data displayed. 

 

YES

 

Display averaging in effect. 

 

 

If no is selected, the following step does not 

appear.

PEr 

030

 

Set averaging period in seconds (0-999).  

Display will update at this interval.

dSP 

SPd

 

Displays MAXIMUM wind speed in right dis-

play.

 

dir

 

Displays Wind Direction degrees 

 

 

(1° resolution) in right display.   

 

 

 

Wind Direction Alarm

ALr 

no

 

WD alarm not used.

 

YES

 

WD alarm activated.

     

 

If no is selected, the following 2 steps do not  

appear.

ALr 

dir

 

Press SELECT to position alarm sector. 

 

 

Press ENTER.

ALr 

SPn

 

Press SELECT to set size (span) of alarm sec-

tor.

 

 

Wind Speed Alarm

ALr 

no

 

WS alarm not used. 

 

YES

 

WS alarm activated. 

      

 

If no is selected, the following step does not  

appear.

ALr 

000

 

WS alarm set point. Press SELECT to change 

digits. ENTER to save.

 

 

 

 

Alarm Delay Time

 

 

If no alarm is selected, this step does not  

appear.

dLY 

030

 

Set alarm delay time in seconds (0-999).

 

 

 

 

 

Sound

Snd 

no

 

No sound with alarm or average update.

 

YES

 

Audible beeper will sound with alarm or avg 

update.

 

 

Test Functions

tSt 

ALr

 

Press SELECT to close alarm relays.

 

 

 

CAL 

0.00

 

Press SELECT to alternate between 0.00 VDC 

and 

 

 

5.00 VDC at "0-5V OUT" terminals. Use to cali

-

brate external devices (recorders, etc..)

ADDITIONAL INFORMATION

ALARMS

Wind speed and wind direction alarm functions are accessed in the 

SETUP

 sequence. Either or both alarms may be used. When activated, 

alarms are indicated on the front panel. When an alarm condition 

exists, the indicator blinks, the associated relay contact closes and 

beeper sounds (if selected). 

 When a delay time is set, the indicator 

will not report an alarm condition until it has existed for one complete 

delay period. Alarm activity ceases when conditions are outside the 

alarm range for one complete delay period. For a "latching" alarm 

effect, use the Wind Tracker alarm contacts to activate an appropriate 

external latching-type relay.

AVERAGING

The Wind Tracker can display instantaneous or averaged wind data.  

Averaging is selected in the SETUP sequence at the prompt  "dSP". 

The average is a block average for the time period selected. The 

display  updates only after each time period has elapsed and will 

hold this information until the next update.

Отзывы: