MIG-160PI/MIG-180PI/MIG-200PI/MIG-250PI
- 5 -
Installment
The welding equipment is equipped with power voltage compensation set. When
power voltage changes between
±
15% of rated voltage, it still works normally.
When using long cable, in order to minimize the reduce of voltage, big section
cable is suggested. If the cable is too long, it will affect the performance of arcing and
other system function, so stated length is suggested.
1
、
Make sure the intake of the machine is not covered or blocked to prevent the
malfunction of the cooling system.
2
、
Use earth cable that the section no less than 6mm
2
to connect the housing and earth,
the method is from the connection in the back of the machine to the earth set, or
make sure the earth end of power switch reaches the earth. Both ways can be
used for better security.
Installment
:
1) Connect the gas flask with CO2 decompression flow meter and the CO2 mouth
behind the machine via gas cable.
2)
Insert the swift plug of earth cable into the swift socket in the front panel.
3) Set the wire wheel with wire on the wheel axis, the wheel hole should be matched
with the wheel fixer.
4) Choose wire slot according to wire size.
5) Loosen the screw of wire-pressing wheel, put the wire into slot via wire-lead tube,
tune the Wire-pressing wheel to fix wire from gliding,but pressure should be suitable
in case the wire distorts and affects wire sending.
6) Wire roll should turn clockwise rotation to let out wire, to prevent wire from
gliding, wire is usually set to the fixed hole on the wheel side. To prevent the bent
wire from getting stuck, please cut off this part of the wire.
7) The MIG torch has been setted inside of the machine just need put the wire into the
torch by hand.