background image

©2022 Yotta Energy  

|

  yottaenergy.com

7

Содержание SolarLEAF SL-1000

Страница 1: ...SolarLEAF SL 1000 User Manual 755 00001 REVISION 5 NOVEMBER 1 2022 www yottaenergy com...

Страница 2: ...NAME____________________________________________________________________ PROJECT SUPERVISOR_______________________________________________________________________________________ INSTALLATION DATE____...

Страница 3: ...omponents 4 Mechanical Installation 4 TRANSPORTATION AND STORAGE 6 OPERATION AND MAINTENANCE 7 Activating the System 7 De Activating the System 7 Grid Outage and Rapid Shutdown 7 Deactivating the syst...

Страница 4: ...a minimum of 6cm from the roof To comply with NFPA 855 no more than 600 SolarLEAF battery storage systems can be installed on a single roof Warning Outdoor commercial use only Not intended for marine...

Страница 5: ...the SolarLEAF as shown Lower the SolarLEAF into the ballast rails on the racking Insert a 370 00018 bolt though the foot of the SolarLEAF and a slot in the ballast rail Attach a 370 00016 WASHER FLAT...

Страница 6: ...matic shows 4 PV panels connected to 4 SolarLEAFS connected to one 4 input micro inverter All connections to the Solar LEAF are low voltage DC 60Vdc DC Input Connect the DC wires from the PV MC4 compa...

Страница 7: ...2022 Yotta Energy yottaenergy com 7...

Страница 8: ...deep sleep Battery cells are monitored by the BMS Battery port is disconnected from the rest of the power electronics All wireless and wired communication is turned off within the SolarLEAF STORAGE Un...

Страница 9: ...ity to store power until a user defined time using a time of discharge profile The profile instructs the SolarLEAF when to produce output port power and the minimum amount of power to produce as long...

Страница 10: ...Disposal Contact your local authorities for proper disposal and recycling regulations DANGER DO NOT CRUSH DISSASSEMBLE DISPOSE OF IN FIRE Glossary MPPT Maximum power point tracking SOC State of Charge...

Страница 11: ...ION The SolarLEAF is to be installed and tested with the TOP facing upwards and the fins facing toward the back The back wall of the unit houses all of the interfaces listed from left to right as foll...

Страница 12: ...Temperature Range 20 C to 43 C Dimensions LxWxD 400mm x 667mm x 108mm 15 75 x 26 25 x 4 25 Enclosure Rating Do not immerse in water Outdoor only IP 67 Do not keep under RH 90 non condensing Do not exp...

Страница 13: ...YOTTAENERGY COM 2101 EAST ST ELMO ROAD STE 150 AUSTIN TEXAS 78744...

Отзывы: