Yoshitake SY-8 Скачать руководство пользователя страница 5

■ EP D T-048■  

5. Maintenance 

 

5.1 Precaution for installation 

Caution 

1. When installing, check the direction of the product so that the fluid flowing and the arrow marked on 

the product are in the same direction. 

* Setting the product in wrong directions prevents the product from performing as intended. 

2. When installing, secure the space to remove the screen. 

* Failure to follow this notice hampers cleaning of the screen. 

3. Do not apply excessive load, torque or vibration to the product. 

* Failure to follow this notice may result in fluid leakage. 

4. Do not apply excessive load, torque or vibration to the product. 

* The foreign matter corresponding to the specified mesh size may not be completely caught 

constitutionally. 

1. Clogging inside the product can be known from the differential pressure measured, when pressure 

gauges are installed in upstream and downstream of the product. [See Fig. 1 in “7. Piping 
Example.”] 

2. The product shall be installed with its cap or cover faced downward. 

* If drainage or similar problem occurs in a steam line, incline the product to the position at which 

the cap or cover is kept horizontally. 

3. If the product can only be installed to run the fluid from the bottom to the top, make sure to install a 

blow valve in order to remove the scale accumulated at the bottom of the riser pipe. [See Fig. 2 in 
“7. Piping Example.”] 

4.When the fluid is steam, connect piping so that the cap or cover faces sideways in order to minimize 

the pooling of drain. [See Fig. 3 in “7. Piping Example.”] 

 
 

5.2 Precaution for operation 

Warning 

1. When the product is used for hot fluid, do not touch the product with bare hands. 

* Failure to follow this notice may result in scalds or injury. 

2. Do not retighten the cap or cover after leading fluid into the product. 

* Failure to follow this notice may damage the gasket and cause outside leakage. 
* Failure to follow this notice may result in scalds or injury.

 

 

Caution 

1. Use the product under a maximum pressure loss below 0.1 MPa. Periodically clean the screen. 

* Failure to follow this notice may damage the screen. 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание SY-8

Страница 1: ...t in death or serious injury Caution This symbol indicates a hazardous situation that if not avoided may result in minor or moderate injury or may result in only property damage Table of Contents 1 Sp...

Страница 2: ...FF flanged If the temperature is over 150 C another material is used for the gasket Please contact us Available with JIS 20K Flanged Up to 50A Available with 20 to 100 mesh screens 2 Dimensions mm No...

Страница 3: ...nominal pipe size is smaller the costs of piping and equipment decreases while the pressure loss through the pipe increases to generate disturbances possibly resulting in pipe wear noise and or vibra...

Страница 4: ...3 EPD T 048 4 3 Pressure Loss Chart Screen 15A to 100A 2 5 7 21 holes cm2 Mesh 80 mesh 125A to 150A 6 2 05 holes cm2 Mesh 80 mesh Nominal size P Pressure loss MPa V Flow rate L min...

Страница 5: ...shall be installed with its cap or cover faced downward If drainage or similar problem occurs in a steam line incline the product to the position at which the cap or cover is kept horizontally 3 If t...

Страница 6: ...ssure gauge to make certain there is no pressure inside the body 1 remove the cap or cover 2 and screen 3 Clean up the screen 3 by compressed air or water 6 2 Precaution for reassembly Caution 1 Clean...

Страница 7: ...product Yoshitake supplies the repair parts for 5 years otherwise individually agreed 3 This warranty does not cover the damage due to any of below 1 Valve seat leakage or malfunction caused by forei...