Yoshitake SY-10 Series Скачать руководство пользователя страница 3

2

                                            ■

EPDT-049a

 

 

4. Dimensions 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

SY-10-10, SY-10-150 

(mm)

 

SY-10-20, SY-10-30, SY-10-300   (mm) 

Nominal 

size

 

H

1

 

ds 

ls 

Plug 

   

Nominal 

size

 

H

1

 

ds 

ls 

Plug 

15A 

180 

100 

24 

70 

R 1/2 

15A 

180 

100  24 

70 

R 1/2 

20A 

180 

100 

24 

70 

R 1/2 

20A 

180 

100  24 

70 

R 1/2 

25A 

200 

113 

33 

80 

R 1/2 

25A 

200 

113  33 

80 

R 1/2 

32A 

220 

138 

46 

100 

R 1/2 

32A 

240 

140  46 

100 

R 1/2 

40A 

220 

138 

46 

100 

R 1/2 

40A 

240 

140  46 

100 

R 1/2 

50A 

250 

165 

56 

120 

R 1/2 

50A 

275 

170  56 

120 

R 1/2 

65A 

300 

185 

73 

125 

R 1/2 

65A 

310 

188  73 

125 

R 1/2 

80A 

320 

210 

88 

145 

R 1/2 

80A 

345 

215  88 

145 

R 1/2 

100A 

380 

270 

108  200 

R 1/2 

100A 

395 

275  108  200 

R 1/2 

125A 

450 

310 

138  230 

R 3/4 

125A 

470 

325  138  230 

R 3/4 

150A 

500 

375 

158  280 

R 3/4 

150A 

520 

380  158  280 

R 3/4 

200A 

600 

470 

208  350 

R 3/4 

200A 

655 

475  208  350 

R 3/4 

250A 

745 

580 

270  450 

R 1 

250A 

780 

580  270  450 

R 1 

 

 

 

5. Operation

 

 

 

 

 

 

 

 

 

 

 

 

 

No.  Parts Name 

Body 

Cover 

Screen 

Gasket 

Plug 

 

Dust, scale, and other foreign substances which flow into the inlet side of the strainer are removed by the 
screen [3]. 

Содержание SY-10 Series

Страница 1: ...erious injury Caution This symbol indicates a hazardous situation that if not avoided may result in minor or moderate injury or may result in only property damage Table of Contents 1 Overview 1 2 Feat...

Страница 2: ...ss 150 300 flanged as standard specifications 2 The standard product has a stainless steel screen of 80 mesh with perforation 3 Specifications Model SY 10 10 SY 10 20 SY 10 30 SY 10 150 SY 10 300 Appl...

Страница 3: ...165 56 120 R 1 2 50A 275 170 56 120 R 1 2 65A 300 185 73 125 R 1 2 65A 310 188 73 125 R 1 2 80A 320 210 88 145 R 1 2 80A 345 215 88 145 R 1 2 100A 380 270 108 200 R 1 2 100A 395 275 108 200 R 1 2 125A...

Страница 4: ...reases to generate disturbances possibly resulting in pipe wear noise and or vibration If the nominal pipe size is too large not only the costs of piping and equipment but also the thermal loss increa...

Страница 5: ...4 EPDT 049a 6 3 Pressure Loss Chart Model SY 10 Strainer Screen 6 8P perforations with 80 mesh filter Nominal size P Pressure loss MPa V Flow rate L min...

Страница 6: ...ct shall be installed with its cover faced downward If drainage or similar problem occurs in a steam line incline the product to the position at which the cover is kept horizontally 6 If the product c...

Страница 7: ...to the residual pressure 2 After checking the pressure gauge to make certain there is no pressure inside the body 1 remove the cover 2 and screen 3 Clean up the screen 3 by compressed air or water 8...

Страница 8: ...improvement without any prior notice After the discontinuation of the product Yoshitake supplies the repair parts for 5 years otherwise individually agreed 3 This warranty does not cover the damage d...

Отзывы: