-5-

                           

EPDT-183c

 

Caution 

1

Please clean the screen regularly since if waste and scales clog the  strainer, the area for 

fluid flow decreases, thereby obstructing smooth flow.     

Neglect will result in too much pressure loss leading to damage of the screen and piping system.   

 

6.3 Removal of the screen   

Check the pressure gauge so that there is no pressure inside the product. 

Model SU-50

50H 

(1) Remove bolts 

(2) Remove cover 

. In case you cannot remove the cover, screw in M8 bolts in the two holes on 

the cover until the cover comes up. (See Fig. 7), and then remove the cover. Remove the M8 
bolts after removing the cover.   

(3) Remove screen 

  from the body 

, and clean with compressed air and cleaning agents.   

 
 
 
 
 
 
 
 
 
 
   

 

 

 

 

 

 

Fig.

  Removal of cover for Model SU-50

50H

Above diagram

 

 

Models SU-50S   

(1) Loosen eye nuts 

  with a screw driver.   

(2) Move arm 

  away from cover 

  so that it does not touch it. (See Fig.

8

) In case of 150A, 

move both arms away.   

(3) Remove cover 

. If you cannot remove the cover, move one of the screws 

  on the cover to 

the other side, and screw in the two screws evenly until the cover comes up. (See Fig. 

8

) Return 

the screws to their original positions after removing the cover 

(4) Remove screen 

  from the body 

, and clean with compressed air and cleaning agents. 

 
 
 
 
  
 
 
 
 

 

 
 
 
 
 
  
 

           

Fig. 8    Removal of covers for Models SU-50S

Above diagram

 

Содержание SU-50

Страница 1: ...d result in death or serious injury Caution Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury It is also used to alert against property damage Con...

Страница 2: ...omize 20 250 mesh net strainers upon request Cautions 1 Please confirm that the indications on the product plate coincide with the specifications of the ordered model Also confirm that the conditions...

Страница 3: ...the nominal size of the strainer is smaller than that for the piping the pressure loss of the strainer may grow resulting in failure to maintain the required pressure at the inlet of the strainer See...

Страница 4: ...de before installing the product The product will not function if it is installed in the wrong direction 2 Please support the piping and fix on the product securely The product may deform from too muc...

Страница 5: ...actual flow volume 1 Disassemble the strainer and clean screen 2 Exchange the pressure gauge 3 Use a strainer with a larger nominal size Refer to Fig Loss of Pressure Alien matter is not removed 1 Scr...

Страница 6: ...hen remove the cover Remove the M8 bolts after removing the cover 3 Remove screen from the body and clean with compressed air and cleaning agents Fig Removal of cover for Model SU 50 50H Above diagram...

Страница 7: ...become impossible to remove the cover 4 In case screen is deformed or damaged exchange it to a new one The product will not function with a deformed or damaged screen 5 Securely assemble each part up...

Страница 8: ...50S Model SU 50 50H Fig 10 Exploded drawing The parts framed rectangle are consumable items The timing of replacement are based on below chart No Name of parts Durable Rough standard O Ring When the c...

Страница 9: ...improvement without any prior notice After the discontinuation of the product Yoshitake supplies the repair parts for 5 years otherwise individually agreed 3 This warranty does not cover the damage d...

Отзывы: