3
■
EPDT-253b
■
6. Precautions for Operation
Caution
1. When installing, check the direction of the product.
* Setting the product in wrong directions hampers the product from performing as intended.
2. When installing, reserve a space required for maintenance and inspection (cleaning of the screen) so
that an operator can pick up the screen from the product.
(1) Clogging inside the product can be known from the differential pressure measured when
pressure gauges are installed in upstream and downstream of the product.
Warning
When the product is used for hot fluid, do not touch the product with bare hands.
* The product having hot fluid may scald your skin.
Caution
Use the product with a maximum pressure loss of 0.1 MPa or below.
Clean the screen periodically.
* Failure to follow this notice may damage the screen.
7. Precaution for Removal from Piping after Brushing
Warning
Before disassembling or inspecting, make sure that the internal pressure is
completely released from the product and the piping.
When the product is used for hot fluid, cool down the product to the condition that it
can be touched with bare hands.
*Residual pressure or hot fluid may result in scalds or injury.
8. Piping Example
Gasket
Temporary strainer
Short pipe