5. Installation 

 

5.1 Precaution for installation 

 

          Caution 

1.  Before

 

connecting the product in the piping, be sure to remove foreign substances and scale from the 

piping. 
*

 

Failure  to  follow  this  notice causes valve  seat  leakage  due  to  the  ingress  of  foreign  substances and 

scale into the product. 

2.  To install the product, check the direction of the product so that the fluid flowing and the arrow marked on 

the product are in the same direction. 
*

 

Wrong direction prevents fluid from flowing. 

3.  Connect  the  product  to  the  piping  so  that  excessive  load,  torque  or  vibration  cannot  be  applied  to  the 

product. Be sure to connect the product to piping firmly. 
*

 

Failure to follow this notice may cause fluid leakage and result in burns or property damage. 

4.  On installation, align center part of the product with that of flange by making fin-shaped part contact with 

bolt as indicated in the figure below. 
 

 
 
 
 
 
 

 
 
 

 

 

6. Operating procedure 

 

6.1 Precaution for operating procedure 

 

          Caution 

Before leading fluid, make sure that there is no danger when the fluid flows to the end of piping. 
* If tightening is not secured, hot fluid may spout out and result in burns. 
* Fluid outflow may cause property damage. 

 

Fin-shaped part

 

(Body of the product) 

 

Bolt 

Flange 

SCV-3 

*The flange is not included in the bundled parts.

 

Содержание SCV-3

Страница 1: ...voided could result in death or serious injury Caution This symbol indicates a hazardous situation that if not avoided may result in minor or moderate injury or may result in only property damage Table of Contents Usage of the Product 1 1 Features 1 2 Specifications 1 3 Structure Dimensions and Weights 1 2 4 Pressure loss 2 5 Installation 3 5 1 Precaution for installation 3 6 Operating procedure 3...

Страница 2: ... Installation posture Installable in any orientation Connection Flangeless wafer type See 8 Connectable flange standard table on Page 4 Minimum valve opening pressure 0 003 MPa Body SCS14A Disc SCS14A The product cannot be disassembled Since a small amount of fluid leaks out of the product it cannot be used for applications requiring complete closing Caution Please confirm that the indications on ...

Страница 3: ... 5 80 5 0 4 32A 32 60 5 28 72 5 49 5 90 5 0 7 40A 40 70 31 5 82 57 5 101 0 9 50A 50 90 40 95 5 76 115 1 5 65A 65 102 45 116 87 142 2 2 80A 80 121 50 129 5 105 5 153 5 2 9 100A 100 145 60 154 5 128 180 4 5 Fig 1 Structure dimensions and weights 4 Pressure loss Fluid water Fig 2 Pressure loss chart V Flow rate L min ΔP Pressure loss MPa ...

Страница 4: ... excessive load torque or vibration cannot be applied to the product Be sure to connect the product to piping firmly Failure to follow this notice may cause fluid leakage and result in burns or property damage 4 On installation align center part of the product with that of flange by making fin shaped part contact with bolt as indicated in the figure below 6 Operating procedure 6 1 Precaution for o...

Страница 5: ... Precaution for maintenance Warning Completely discharge the internal pressure from the valves lines and equipment and cool the valve down to a level where you can touch it with bare hands before disassembly and inspection Failure to do so may result in injury or burns due to residual pressure or spillage around the valve 8 Connectable flange standard table SCV 3 Nominal size JIS ASME JPI PN EN DI...

Страница 6: ...A φ 159 φ 115 φ 159 φ 129 M16 130 8 The bundled bolts and nuts are not made of stainless steel The inlet gasket is equivalent to JIS B2404 Table4 10K dimensions The flange is not included in the bundled parts Caution 1 As shown in Table 1 the Inlet diameters of the gasket differ between the inlet side and the outlet side Refer to Table 1 to avoid piping mistakes Failure to follow this notice cause...

Отзывы: