Yoshitake PG-2 Скачать руководство пользователя страница 2

 

EPDT-299

 

 

1. Specification 

 

1.1 Specification 

 

Model 

PG-2 

Application 

Steam, gas, liquid *1 

Maximum temperature 

60

  *2 

Largeness 

φ

100

 

Case shape 

Type A 

Pressure range 

0 to 0.25 / 0.4 / 0.6 / 1.0 / 1.6 / 2.5 / 4.0 MPa 

0 to 2.5 / 4.0 / 6.0 / 10 / 16 / 25 / 40 bar (Dual scale dial indicates pressure in bar 

and psi.) 

Material 

Case   

SUS 

Bourdon tube 

SUS 

Spanner 

flats 

SUS 

Connection 

G3/8, BSPT1/2, NPT1/2 

*1 If using oxygen, degrease treatment is needed. If using oxygen, please contact us. 
*2 If application exceeds maximum temperature, use the product with siphon pipe. 
*3 The product cannot be adjusted or disassembled.

 

*4 Please keep the product from water and use it in a dry place   
 

1.2 Accuracy of pressure gauge (acceptable tolerance)

 

Scale range is according to Fig. 1. 

(%) 

Scale range A 

Scale range B 

±1.6 

±2.4 

 
 
 

 

 
 
 
 

            Caution 

Please confirm that the indications on the product correspond with the specifications 
of the ordered product model before use. 
* If they are different, do not use the product and contact us. 

 

 

 

 

 

Fig. 1 

*Value of acceptable tolerance is 
expressed  in  percentage  of 
pressure span (all scale range). 

Side 25% 

Scale range B 

Side 25% 
Scale range B 

50% 

Scale range A 