Yoshitake GD-46 Series Скачать руководство пользователя страница 13

12

 

 

EPDT-166f

 

1 1.

Maintenance

 

1 1. 1  

Troubleshooting guide

 

      Problem

 

 

 

 

       

Possible cause 

Corrective action 

  Reduced pressure 
is higher than the set 
pressure 

1.

The cap (17) is left in water pressure 

check status. 

2.

Diaphragm (7) is damaged. 

3.

Spindle O ring (6) is damaged. 

 

4 .

Foreign  object  is  pinched  between 

valve  (2)  and  valve  seat.  Valve  or 
valve seat is damaged. 

1.

Invert the cap (17) so that its flat surface is on 
upside. 

2.

Replace the diaphragm with a new set. 

3.

Replace the diaphragm with a new set 

 

4.

Remove the foreign materials. 

If  the  valve  (2)  is  damaged,  replace  it  with  a 
new one. 
If the valve seat is damaged, replace the 

valve body (1) with a new one. 

  Low flow rate       

1.

Sliding movement of valve stem O ring 

(5) is disturbed by water scale, 
deposits, etc. 

2.

Strainer (19) is clogged. 

3.

Pressure is set low. 

4.

Water shut off valve (41) is closed. 

1.

Clean the inside of the valve body and replace 

the diaphragm with a new set. 

2.

Clean the strainer (19). 

3.

Adjust the pressure following the adjusting 
steps. 

4.

Open the water shut off valve (41). 

 
 
 
 
 
  External leakage 

1.

Set screw (23) is loosened. 

2.

Valve cap (12) is loosened. 

3.

O ring (13) is damaged. 

4.

Strainer cap (21) is loosened. 

5.

O ring (22) is damaged. 

6.

Union nut (33), (34) or (41) is loosened. 

7.

Gasket (30) or (43) is damaged. 

8.

Pressure gauge joint (24) is loosened. 

9.

Foreign object is stuck in pressure 

gauge joint (24). 

1.

Retighten the round head screw (23). 

2.

Retighten the valve cap (12). 

3.

Replace the O ring (13) with a new one. 

4.

Retighten the strainer cap (21).   

5.

Replace the O ring (22) with a new one. 

6.

Retighten the union nut (33), (34) and (41). 

7.

Replace the gasket (30),(43). 

8.

Remove the pressure gauge joint (24). Apply 
seal tape to the threads and attach the joint to 
the valve body (1). 

9.

Replace the pressure gauge joint (24) with a 
new one. 

 
  1 1 .2 

Precaution for maintenance and inspection

 

WARNING

 

(1)

  Completely  discharge  the  pressure  inside  of  the  product  and  piping  before  disassembly  and 

inspection. Disassembly and inspection must be conducted by an experienced professional.

 

Residual pressure, if any, may blow out the fluid, causing bodily injury or contamination on 

surroundings.

 

(2)

 Never touch the product with bare hands when hot fluid is used.

 

Hot fluid may cause burns.

 

CAUTION

 

(1)

 For troubles other than those described in 11.1 Troubleshooting guide, contact us.

 

(2)

 During disassembling, internal fluid flows out. Discharge it into a suitable container.

 

Fluid spills will contaminate surroundings.

 

(3)

 When starting operation after interval of an extended period, turn on a faucet and check the 

water supply pressure.

 

In case of a trouble such as poor water pressure, adjustment work must be done by an 

experienced professional.

 

(4)

 Synthetic rubber is a consumable part. The replacement interval of the synthetic rubber part 

greatly varies depending on the use conditions. The general guide for the replacement 
interval is shown below.

 

 

Recommended replacement interval

 

Parts name/number

 

 

3 years

 

Diaphragm set, Valve (2)

 

5 years

 

O rings (13),(22),(18)     
Gaskets (30),(43)

 

  Refer to “12. Exploded drawing” for the numbers in brackets. 

GD-46 is recommended to be replaced at the same time of the replacement of water meter. 

 

Содержание GD-46 Series

Страница 1: ...property damage Contents Applications Model 2 1 Composition of model name 2 2 Model list Specifications Dimensions 4 1 Dimensions and weights 4 2 Dimensions of heat insulating material 4 3 Dimensions...

Страница 2: ...for inlet outlet Parallel male thread G1 for pipes attached to meter socket etc Male thread R3 4 compatible with cores for P V or P Female thread Rc3 4 with built in P V compatible tube end core Femal...

Страница 3: ...ream of the valve 0 10 MPa or more w check valve 30 L min Pressure difference between upstream and downstream of the valve 0 10 MPa or more Pressure check function Pressure gauge joint JIS Rc1 8 Press...

Страница 4: ...6KK 46KKC Rc3 4 Rc3 4 214 1 5 GD 46PL 46PLC 46PK 46PKC R3 4 Rc3 4 216 1 4 GD 46LP 46LPC 46KP 46KPC Rc3 4 R3 4 216 1 4 GD 46PG R3 4 G1 165 1 2 GD 46GP 46GPC G1 R3 4 165 1 2 GD 46LG 46KG Rc3 4 G1 163 1...

Страница 5: ...Water shut off valve has no insulating material Dimensions with pressure gauge option With type A pressure gauge With type D pressure gauge Note Secure the space at least shown above before pressure...

Страница 6: ...5 EPDT 166f Flow characteristic curve Noise characteristic curve w o check valve...

Страница 7: ...cap nut 21 Strainer cap 11 Spring cover 44 Heat insulating material 14 Adjusting spring Before applying fluid the adjusting spring 14 compressed by the adjusting screw 15 presses down the diaphragm 7...

Страница 8: ...7 EPDT 166f Installation Piping example Example Example 2...

Страница 9: ...Larger the space easier the maintenance and inspection works When piping synthetic tube like polyvinyl chloride never introduce the adhesive material into the product The adhesive material can cause t...

Страница 10: ...the fluid caused by temperature increase 14 If fluid remains inside the reducing valve for a long time the sliding parts become stuck resulting in malfunction of the valve 15 Do not apply excessive lo...

Страница 11: ...al pressure in the piping before water pressure inspection If internal pressure remains inside remove it Remove the cap and turn it out make concave portion upward and screw it firmly onto the spring...

Страница 12: ...it into the pressure gauge joint Fig 3 Remove the cap By checking the pressure gauge turn the adjusting screw to adjust the reduced pressure to a desired level Fig 4 The reduced pressure increases whe...

Страница 13: ...ace the O ring 22 with a new one Retighten the union nut 33 34 and 41 Replace the gasket 30 43 Remove the pressure gauge joint 24 Apply seal tape to the threads and attach the joint to the valve body...

Страница 14: ...shut off valve 41 strainer 19 and the pressure setting If they are OK follow the procedure described in 11 3 Disassembling steps 1 5 and check the diaphragm set and valve body External leakage Locate...

Страница 15: ...performance When removing the strainer cap place a suitable receiver under it See Fig 6 When cleaning the strainer do not remove it from the strainer cap Disassembling the strainer may cause damage t...

Страница 16: ...15 EPDT 166f Exploded drawing Refer to the following page for a part table...

Страница 17: ...Gasket 7 Diaphragm 32 Union Nipple 8 Diaphragm Shell 33 Union Nut 9 Washer 34 Union Socket 10 Domed Cap Nut 35 Tube end core 11 Spring Cover 37 Nipple for Check valve 12 Valve Cap 38 Socket for Check...

Страница 18: ...with check valve K joint with check valve GD 46 GD 46PP GD 46LL GD 46KK GD 46PL GD 46LP GD 46PK GD 46KP GD 46PG GD 46GP GD 46LG GD 46GL GD 46KG GD 46GK GD 46PPC GD 46LLC GD 46PLC GD 46LPC GD 46KKC GD...

Отзывы: