YO Meter Pulse
User guide
v1.2
page 24/27
Payload decoder
If you want to connect to your own server you have to decode the payload specific to each device. To
do this you need a payload decoder which can be downloaded from
. Extended
documentation of the protocol can be found at
.. An exemplary payload produced
by YO Meter Pulse is presented below with division into each measurement marked together with
decoded values whose interpretation is described in the Payload description document.
Example of YO Meter Pulse payload with description:
02:00:00:00:08:00:01:11:a2:0d:00:01:00:f8:10:00:00:37:5c:00:07:00:00:00:00:00:00:f7:a9
Payload header
First measurement (battery voltage)
0x02
0x00
0x00
0x00
0x08
0x00
0x01
0x11
0xA2
ver = 2
cnt = 0
pct [s] = 0
type = 2
prec = 0
md [s] = 0
addr_len = 0
meas_len = 2
val = 4514
(4514 [mV])
Second measurement (temperature)
0x0D
0x00
0x01
0x00
0xF8
type = 3
prec = 1
md [s] = 0
addr_len = 0
meas_len = 2
val = 248
(24,8 [°C])
Third measurement (relative humidity)
0x10
0x00
0x00
0x37
type = 4
prec = 0
md [s] = 0
addr_len = 0
meas_len = 1
val = 55
(55 [%])
Fourth measurement (pulse counter - periodic and persistent)
0x5C
0x00
0x07
0x00 0x00 0x00 0x00 0x00
0x00
0xF7
0xA9
type = 23
prec = 0
md [s] = 0
addr_len = 0
meas_len = 8
val = 0
(0 [-])
val = 63401
(63 401 [-])