YO Ambience
User guide
v1.2
page 17/27
DEVICE PARAMETERS
NAME
DESCRIPTION
POSSIBLE
VALUES
DEFAULT
VALUE
READ/
WRITE
measinterval
Measuring and sending interval
LoRa [s]
1–999999
3600
R/W
co2calibval
Calibration value of CO
2
sensor
0 - 9999
0
R/W
tempoffset
Temperature offset in [°C]
-20.0 - 20.0
0
R/W
iluminancecoeff
Illuminance coefficient
0.0 - 10.0
3.5
R/W
Parameters description
-
nwktype:
used for setting the device as a public or private network type.
-
acttype:
used for setting the device in ABP or OTAA mode.
-
deveui, …, appskey:
predefined addresses and keys. These parameters are generated using
multiple IDs specific to the particular MCU and are unique for each device. They can also be
changed if needed.
-
interval:
determines the interval for sending broadcast packets, used to connect to every BLE
receiver around the device.
-
subband:
used for setting the communication frequency sub-band in LoRaWAN.
-
measinterval:
interval for sending each LoRa payload.
-
co2calibval
: calibration value of the CO
2
sensor. This parameter provides high initial and
long-term accuracy. It enables the sensor to immediately restore the highest accuracy with
the assistance of a CO
2
reference value. This parameter is used if the measurement stability
deviates. A value of 0 means that calibration is disabled.
-
tempoffset
: the offset value added to the temperature measurement.
-
illuminancecoeff
: parameter that tunes the illumination intensity sensor to account for the
attenuation of the light beam travelling through the optical fibre. This parameter is
predefined.