background image

YO 360

User guide

v1.2

page 8/25

Figure 5

Exemplary relative humidity monitoring chart.

Accelerometer

The accelerometer sensor is providing position of a device in X, Y, Z axes and stores data about what
time it was moved to another location. Accelerometer informs in which position measurements of
temperature and humidity were done.

Figure 6

Exemplary accelerometer monitoring chart position X.

www.yo

sensi

.

io

Содержание YO 360

Страница 1: ...YO 360 User guide v1 2...

Страница 2: ...notes Released Version Key changes 25 08 2022 1 0 Initial release 20 06 2023 1 1 Added configuration node with Yosensi Management Platform 31 07 2023 1 2 Changed description of connecting nodes with Y...

Страница 3: ...y 7 Accelerometer 8 Battery condition 10 Installation 11 Package contents 11 Safety precautions 11 Installation guide 12 Operation 15 IoT system components 15 Device configuration 16 Configurable para...

Страница 4: ...virtually any place The enclosure is suitable for indoor use Figure 1 Device top view Device sticker placed on the bottom of the device enclosure contains information about model version LoRaWAN regi...

Страница 5: ...tion failed to receive an acknowledgement from LoRaWAN Server within specified timeout Single flash White LoRaWAN communication LoRaWAN frame sent confirmation from LoRaWAN Server after receiving the...

Страница 6: ...eter 47mm Height 13mm Colour White Black Mounting method Chose from No handles One handle mounting hole Two oval handles Strap Enclosure material ABS Level of protection IP40 Weight 18 6 g Operating c...

Страница 7: ...rom 5 C to 60 C Relative humidity 0 to 100 2 at 20 to 80 Accelerometer 180 on X Y Z axes 0 1 from 40 C to 85 C Internal Temperature and relative internal humidity Temperature and relative humidity are...

Страница 8: ...e accelerometer sensor is providing position of a device in X Y Z axes and stores data about what time it was moved to another location Accelerometer informs in which position measurements of temperat...

Страница 9: ...YO 360 User guide v1 2 page 9 25 Figure 7Exemplary accelerometer monitoring exemplary chart position Y Figure 8 Accelerometer monitoring exemplary chart position Z www yosensi io...

Страница 10: ...ndition Battery voltage is used to monitor its condition to spot anomalies like sudden drop or its current condition based on voltage drop over time in comparison to initial voltage rating Figure 9 Ba...

Страница 11: ...ons near inside electronics Be careful while handling the device dropping it may cause damage that will affect the sensors and other electronics inside When installing the device on the wall remember...

Страница 12: ...YO 360 User guide v1 2 page 12 25 Installation guide 1 Unscrew the device remove 4 screws from the enclosure Figure 10 Device opening instructions www yosensi io...

Страница 13: ...o the polarity Figure 11 Device battery assembling instructions 3 Assemble the device The order of the elements is important Place the PCB B at the top of the enclosure A Then insert the seal C Fit th...

Страница 14: ...nents to the enclosure according to the diagram Place the PCB in the enclosure with the battery basket facing up Figure 13 Matching the PCB to the enclosure instructions 5 The device is on Screw it ba...

Страница 15: ...y 2 Gateway device similar to routers equipped with a LoRa concentrator that receives LoRa packets and send them to the Internet connected server 3 Server in most cases a cloud based service where dat...

Страница 16: ...onnect to the LoRaWAN ble generic bluetooth settings device dynamic individual configuration for a specific device the structure of this section is different for each device Sample configuration file...

Страница 17: ...UI Extended Unique Identifier 8 B HEX predefined R W appeui Application EUI 8 B HEX predefined R W appkey Application Key 16 B HEX predefined R W trials Join request trials 1 9 3 R W lorawan abp devad...

Страница 18: ...or setting the device in ABP or OTAA mode deveui appskey predefined addresses and keys these parameters are generated using multiple IDs specific to the particular MCU and are unique for each device t...

Страница 19: ...0 3 911 7 MHz channels 40 47 6 Sub band 7 911 9 913 3 MHz channels 48 55 7 Sub band 8 915 5 914 9 MHz channels 56 63 8 AU915 Sub band 1 915 2 916 6 MHz channels 0 7 1 2 R W Sub band 2 916 8 918 2 MHz...

Страница 20: ...see three different buttons Configure here you can change and upload parameters of the device Update firmware here you can update the firmware from version 3 4 0 and newer Recover device this section...

Страница 21: ...port yosensi io The application is a representation of each system and together with nodes definitions are created by customers Basic integration of a Node and Yosensi Management Platform is described...

Страница 22: ...and fill in Node ID deveui and OTAA Key otaa section appkey All device identifiers are provided by the support while ordering the nodes Select a model that is compatible with your device it affects th...

Страница 23: ...Node configuration Click on the link in the Node Name column Go to the KEYS tab and switch Lora Type from OTAA to ABP and fill in the blank spaces then press update Identifiers of Device Address devad...

Страница 24: ...Profile which is the region definition 4 Proceed to the application by clicking its name on the list and press the button to add a node Choose the option Add via bluetooth Select the device to add The...

Страница 25: ...xample of YO 360 payload with description 02 00 00 00 08 00 01 0b 62 0d 00 01 00 f6 10 00 00 2f 41 00 15 19 ff f9 00 1e 00 5b Payload header First measurement battery voltage 0x02 0x00 0x00 0x00 0x08...

Отзывы: