YORKVILLE AM100 Скачать руководство пользователя страница 2

IMPORTANT SAFETY INSTRUCTIONS

safety-4v2.eps Aug 26/05

CAUTION

:

TO REDUCE THE RISK OF ELECTRIC SHOCK, DO

NOT REMOVE COVER (OR BACK).

NO USER SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED

SERVICE PERSONNEL.

INSTRUCTIONS PERTAINING TO A

RISK OF FIRE, ELECTRIC SHOCK,

OR INJURY TO PERSONS

Read Instructions

The Owner’s Manualshould be read and understood 
before operation of your unit. Please, save these instruc-
tions for future reference.

Packaging

Keep the box and packaging materials, in case the unit 
needs to be returned for service.

Warning

When using electric products, basic precautions should 
always be followed, including the following:

Power Sources

Your unit should be connected to a power source only of the voltage 
specified in the owners manual or as marked on the unit. This unit has 
a polarized plug. Do not use with an extension cord or receptacle 
unless the plug can be fully inserted. Precautions should be taken so 
that the grounding scheme on the unit is not defeated.

Hazards

Do not place this product on an unstable cart, stand, tripod, bracket or 
table. The product may fall, causing serious personal injury and serious 
damage to the product. Use only with cart, stand, tripod, bracket, or 
table recommended by the manufacturer or sold with the product. 
Follow the manufacturer’s instructions when installing the product and 
use mounting accessories recommended by the manufacturer.

The apparatus should not be exposed to dripping or splashing water; 

no objects filled with liquids should be placed on the apparatus.

Terminals marked with the “lightning bolt” are hazardous live; the 

external wiring connected to these terminals require installation by an 
instructed person or the use of ready made leads or cords.

No naked flame sources, such as lighted candles, should be 

placed on the apparatus.

Power Cord

The AC supply cord should be routed so that it is unlikely that it will be 
damaged. If the AC supply cord is damaged DO NOT OPERATE THE UNIT.

Service

The unit should be serviced only by qualified service personnel.

AVIS:

AFIN DE REDUIRE LES RISQUE DE CHOC ELECTRIQUE,

N’ENLEVEZ PAS LE COUVERT (OU LE PANNEAU ARRIERE)

 

NE CONTIENT AUCUNE PIECE

REPARABLE PAR L’UTILISATEUR.

CONSULTEZ UN TECHNICIEN QUALIFIE

POUR L’ENTRETIENT

INSTRUCTIONS RELATIVES AU RISQUE

DE FEU, CHOC ÉLECTRIQUE, OU

BLESSURES AUX PERSONNES

Veuillez Lire le Manuel

Il contient des informations qui devraient êtres comprises 
avant l’opération de votre appareil. Conservez S.V.P. ces 
instructions pour consultations ultérieures.

Emballage

Conservez la boite au cas ou l’appareil devait être 
retourner pour réparation.

Attention:

Lors de l’utilisation de produits électrique, assurez-vous 
d’adhérer à des précautions de bases incluant celle qui 
suivent:

Alimentation

L’appareil ne doit être branché qu’à une source d’alimentation 
correspondant au voltage spécifié dans le manuel ou tel qu’indiqué sur 
l’appareil. Cet appareil est équipé d’une prise d’alimentation polarisée. 
Ne pas utiliser cet appareil avec un cordon de raccordement à moins 
qu’il soit possible d’insérer complètement les trois lames. Des 
précautions doivent êtres prises afin d’eviter que le système de mise à 
la terre de l’appareil ne soit désengagé.

Risque

Ne pas placer cet appareil sur un chariot, un support, un trépied ou une 
table instables. L’appareil pourrait tomber et blesser quelqu’un ou subir 
des dommages importants. Utiliser seulement un chariot, un support, 
un trépied ou une table recommandés par le fabricant ou vendus avec 
le produit. Suivre les instructions du fabricant pour installer l’appareil et 
utiliser les accessoires recommandés par le fabricant.

Il convient de ne pas placer sur l’appareil de sources de flammes 

nues, telles que des bougies allumées.

L’appeil ne doit pas être exposé à des égouttements d’eau ou des 

éclaboussures et qu’aucun objet rempli de liquide tel que des vases 
ne doit être placé sur l’appareil.

Les dispositifs marqués d’une symbole “d’éclair” sont des parties 

dangereuses au toucher et que les câblages extérieurs connectés à 
ces dispositifs de connection extérieure doivent être effectivés par un 
opérateur formé ou en utilisant des cordons déjà préparés.

Cordon d’Alimentation

Évitez d’endommager le cordon d’alimentation. N’UTILISEZ PAS 
L’APPAREIL si le cordon d’alimentation est endommagé.

Service

Consultez un technicien qualifié pour l’entretien de votre appareil.

Содержание AM100

Страница 1: ...iagara Falls New York 14305 USA Voice 716 297 2920 Fax 716 297 3689 WORLD HEADQUARTERS WEB ACCESS http www yorkville com CANADA Yorkville Sound 550 Granite Court Pickering Ontario L1W 3Y8 CANADA Voice 905 837 8481 Fax 905 837 8746 Printed in Canada Quality Innovation Since 1963 TYPE YS1004 ...

Страница 2: ...IQUE N ENLEVEZ PAS LE COUVERT OU LE PANNEAU ARRIERE NE CONTIENT AUCUNE PIECE REPARABLE PAR L UTILISATEUR CONSULTEZ UN TECHNICIEN QUALIFIE POUR L ENTRETIENT INSTRUCTIONS RELATIVES AU RISQUE DE FEU CHOC ÉLECTRIQUE OU BLESSURES AUX PERSONNES Veuillez Lire le Manuel Il contient des informations qui devraient êtres comprises avant l opération de votre appareil Conservez S V P ces instructions pour cons...

Страница 3: ...CAP T R RAD 2 FLM 3 6116 1 4W 10K0 1 MINI MF T R RES 37 5314 100N 50V 10 CAP T R BEAD X7R 13 4830 1 4W 15K 5 T R RES 3 5231 220N 63V 10 CAP T R RAD 2 FLM 3 6123 1 4W 20K0 1 MINI MF T R RES 4 5234 470N 63V 10 CAP T R RAD 2 FLM 1 4777 1 4W 21K5 1 T R RES 1 5255 __1U 63V 20 CAP T R RAD 2 EL 2 4917 1 4W 31K6 1 T R RES 1 5256 __1U 63V 5 CAP T R RAD 2 FLM 6 4840 1 4W 33K 5 T R RES 1 5259 __4U7 63V 20 CA...

Страница 4: ...CRO STRAP 3 4 X22CM VELSTRAP 21 3481 8 3 18 SJT AC LINE CORD 250 CLIPS 22 YSM 1WFR 6 5 INCH WOOFER 23 7418 8R 30W TWEETER PIEZO KSN1056A Internal Electronic Components 1310 4200 BLOC 80B 100G S120B 100K XFMR 2439 1 25 AMP SLO BLO 25X1 25 FUSE 3608 10 9C 24AWG RIBBON HITMP 0 1 3745 DUAL XSISTOR PBL SPRING PLATE ZN 3830 TO218 PREGREASED MICA 56 78 2AP 3850 TO 220 PLASTIC TRANSISTOR INSULATOR 4594 1 ...

Страница 5: ... 4 High Z Low Z Input 1 Gain Pot Input 2 Gain Pot EQ In 1 In 2 BLOCK DIAGRAM am100 2v0 ai Foot EFX Switch In Out EFX Return ch 2 EFX Send ch 2 Balanced Line Out Dry ch 1 ch 2 Right Bus Left Bus Mono 1 4 Balanced Gain 2 Gain 1 Amber LED ON for Bank A Channel Inputs Speaker Outputs Effects Loop and Line Out Low Mid High DESIGNED AND MANUFACTURED BY YORKVILLE SOUND On Off On Off ...

Страница 6: ...W C30 4N7 250V R250 100R 1 0W R254 100R 1 0W 3414 1 4W 1K R35 C3 100P 100V C26 2200U 50V D4 1N5402 D2A 4007 1 4W 1K0 R9 C29 330U 25V R205 330R 1 2W RED CLIP LD2 1 4W 1K5 R70 ZD3 16V0 1N4745A 1W0 8 V 4 V U1 C 1 4W 47K R47 LD3 GRN C252 10N 50V 4 V 11 V U8 E 3425 S3 A 1 4W R33 1K 1 4W 1K R23 4 V 11 V U9 E 1 4W 10K R28 1 4W R40 100K U9 A TLO74CN U9 B TLO74CN 1 4W R232 10K0 63V 220N C65 1 4W R90 33R B ...

Страница 7: ...X 200V 27P R15FX A 1 4W 10PIN 330RX9 R13FX 1 4W MINI 1K TO92 MPSA13 Q2FX 5105 R28FX 1 4W MINI 220R R29FX 1 4W MINI 220R C18FX 100V 10N R15FX H 1 4W 10PIN 330RX9 U4FX B U4FX C U4FX A U4FX F U4FX H R12FX 1 4W MINI 1K R100FX F 1 4W 10PIN _10KX9 R100FX G 1 4W 10PIN _10KX9 R100FX H 1 4W 10PIN _10KX9 R100FX C 1 4W 10PIN _10KX9 R100FX A 1 4W 10PIN _10KX9 R100FX D 1 4W 10PIN _10KX9 D_GND Link R10FX 1 4W M...

Страница 8: ...10K 10K 1K2 2K 10K 1K 2N2 2N2 470R 100N 470K 330R 330R 1 2W 330R 1 2W 330R 1 2W 1M 100P 4148 18N 5K1 470N 33R 10K0 10K0 2K 2K 100N 100N 10K0 2K49 4148 RED 10N 100P 10K0 4148 15P 1U 2N2 25V 330U 15K 1N 4K7 TLO74CN 100K 100K 63V 10U 1K 100K 63V 1U 10K0 15K 10K0 220N 100N 10N 470K 22V0 10K0 10K0 180K 2K2 1U 10K0 4148 63V 4U7 1N5402 100N 1 0W 100R 1 0W 100R 1 0W 100R 1U 1U 220N 68N 68N 33U 16V 10K0 10...

Страница 9: ...LINE CORD 4 BLACK DBL INS AM100 EXPORT AC WIRING May 23 2000 8 48 6 L OCKW ASHER CHASSI S 1309 4 BLACK DBL INS ...

Страница 10: ...LINE CORD 4 BLACK DBL INS AM100 EXPORT AC WIRING JUN 25 2001 8 48 6 L OC KWAS HER CHASSIS 1309 4 BLACK DBL INS WHITE BLACK YEL RED BLK BLUE BLK YEL RED RED ...

Отзывы: