background image

410821-YTG-B-1008

2

Johnson Controls Unitary Products

Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.

FRONT

LEFT SIDE

Combustion Air Inlet

Condensate Drain
(Downflow)

Thermostat
Wiring

28.5”

Gas Pipe
Entry

Electrical
Entry

Condensate
Drain

Thermostat
Wiring

RIGHT SIDE

Condensate Drain
(Downflow)

14”

1”

1.5”

23”

Combustion Air Inlet

Gas Pipe
Entry

Electrical
Entry

Condensate
Drain

Optional Return Air
Cutout (Either side)

30.25”

A

33”

C

SUPPLY END

.56”

.56”

20”

B

3”

23.8”

.56”

Combustion
Air Inlet

RETURN END

B

24.25”

2” Vent
Connection
Outlet

2” Vent
Connection
Outlet

2” Vent
Connection
Outlet

Cabinet and Duct Dimensions

Models

Nominal

CFM (m

3

/min)

Cabinet

Size

Cabinet Dimensions (Inches)

Approximate

Operating Weights

A

B

C

Lbs

YP9C060B12MP11

1200

B

17 1/2

16 3/8

13 1/4

122

YP9C080B12MP11

1200

B

17 1/2

16 3/8

14 3/4

126

YP9C080C16MP11

1600

C

21

19 7/8

16 1/2

136

YP9C100C16MP11

1600

C

21

19 7/8

18 1/4

142

YP9C100C20MP11

2000

C

21

19 7/8

18 1/4

145

YP9C120D20MP11

2000

D

24 1/2

23 3/8

21 3/4

156

Ratings & Physical / Electrical Data

Models

Input

Max/Min

Output

Max/Min

AFUE

%

Nominal

Airflow

Total 

Unit

Amps

Air Temp. 

Rise Max 

Input

Air Temp. 

Rise Min

Input

MBH

MBH

CFM

°F

°F

YP9C060B12MP11

60/21

58/20

97.5

1200

7.0

40-70

20-50

YP9C080B12MP11

80/28

77/27

97.5

1200

7.5

40-70

20-50

YP9C080C16MP11

80/28

78/27

97.7

1600

10.0

40-70

20-50

YP9C100C16MP11

100/35

97/34

97.7

1600

10.0

40-70

20-50

YP9C100C20MP11

100/35

97/34

97.7

2000

12.0

45-75

25-55

YP9C120D20MP11

120/42

116/40

98.0

2000

12.0

45-75

25-55

Models

Max. Outlet

Air Temp

Blower

Blower

Wheel

Size

Max 

Over-Current 

Protect

Min. wire Size 

(awg) @ 75 ft 

one way

°F

HP

Amps

YP9C060B12MP11

170

1/2

4.8

11 x 8

15

14

YP9C080B12MP11

175

1/2

4.8

11 x 8

15

14

YP9C080C16MP11

175

3/4

7.5

11 x 10

15

14

YP9C100C16MP11

175

3/4

7.5

11 x 10

15

14

YP9C100C20MP11

180

1

14.5

11 x 11

20

12

YP9C120D20MP11

180

1

14.5

11 x 11

20

12

Содержание YP9C Series

Страница 1: ...irculating blower Modulating operation from 100 to 35 input in 100 increments with nearly constant temperature rise Easily applied in upflow horizontal left or right or downflow installation with minimal conversion necessary Compact easy to install ideal height 33 tall cabinet ECM variable speed drive for cooling SEER enhancement improved comfort with optional airflow delay profiles and continuous...

Страница 2: ... B 17 1 2 16 3 8 13 1 4 122 YP9C080B12MP11 1200 B 17 1 2 16 3 8 14 3 4 126 YP9C080C16MP11 1600 C 21 19 7 8 16 1 2 136 YP9C100C16MP11 1600 C 21 19 7 8 18 1 4 142 YP9C100C20MP11 2000 C 21 19 7 8 18 1 4 145 YP9C120D20MP11 2000 D 24 1 2 23 3 8 21 3 4 156 Ratings Physical Electrical Data Models Input Max Min Output Max Min AFUE Nominal Airflow Total Unit Amps Air Temp Rise Max Input Air Temp Rise Min I...

Страница 3: ...BR0517 or 1BR0617 For 17 1 2 cabinets 1BR0521 or 1BR0621 For 21 cabinets 1BR0524 or 1BR0624 For 24 1 2 cabinets 1BR05xx series are galvanized steel filter racks 1BR06xx are pre painted steel filter racks to match the appearance of the fur nace cabinet COMBUSTIBLE FLOOR BASE KIT For installation of these furnaces in downflow applications directly onto combustible flooring material These kits are re...

Страница 4: ...mper Settings Hi Cool Lo Cool Hi Cool Lo Cool COOL Jumper ADJ Jumper 1305 850 1290 840 H B 1100 715 1090 710 MH B 1065 690 1015 660 H A 1000 650 1000 650 MH A 960 625 960 625 H C 760 495 760 495 ML B 900 585 900 585 MH C 660 430 660 430 L B 690 450 680 445 ML A 600 400 600 400 L A 620 400 620 400 ML C 550 400 540 400 L C High Low Speed Cooling CFM 080C16 100C16 Jumper Settings Hi Cool Lo Cool Hi C...

Отзывы: