036-21570-002 Rev. D (0605)
8
Unitary Products Group
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric
power input during the same period.
— = Not Applicable.
HEATING PERFORMANCE - With Air Handler
UNIT
MODEL*
AIR
HANDLER
COIL
1
MODEL
ARI HEATING
2
OUTDOOR TEMP
3
47
17.00
HSPF
-3 7 27 37 57
MBH COP KW MBH COP KW STD MBH KW MBH KW MBH KW MBH KW MBH KW
1 PH 12 SEER HP WITH N1AH/G2FD
YMA02411
N1AHB08 G2FD030(S,H)17(T) 24.0
3.46 2.03 13.8 2.44 1.66
8.00
7.0
1.41 10.4 1.53 15.9 1.73 17.9 1.79 27.4 2.16
N1AHB12 G2FD030(S,H)17(T) 24.0
3.46 2.03 13.8 2.44 1.66
8.00
7.0
1.41 10.4 1.53 15.9 1.73 17.9 1.79 27.4 2.16
YMA03011
N1AHB08 G2FD030(S,H)17(T) 30.0
3.28 2.68 17.8 2.44 2.14
8.00
9.8
1.80 13.9 1.97 20.4 2.27 22.9 2.38 34.0 2.86
N1AHB12 G2FD030(S,H)17(T) 30.0
3.28 2.68 17.8 2.44 2.14
8.00
9.8
1.80 13.9 1.97 20.4 2.27 22.9 2.38 34.0 2.86
N1AHB08 G2FD036(S,H)17(T) 35.2
3.54 2.91 21.0 2.54 2.42
8.00
11.5 2.10 16.3 2.26 23.2 2.52 25.4 2.62 39.9 3.08
YMA03611
N1AHB12 G2FD036(S,H)17(T) 35.2
3.54 2.91 21.0 2.54 2.42
8.00
11.5 2.10 16.3 2.26 23.2 2.52 25.4 2.62 39.9 3.08
N1AHC16 G2FD036(S,H)21(T) 35.2
3.54 2.91 21.0 2.54 2.42
8.00
11.5 2.10 16.3 2.26 23.2 2.52 25.4 2.62 39.9 3.08
YMA04211
N1AHC16 G2FD048(S,H)21(T) 42.0
3.50 3.52 28.2 2.50 3.31
8.00
18.7 3.14 23.5 3.22 29.3 3.26 30.5 3.22 47.2 3.63
N1AHD20 G2FD048(S,H)24(T) 42.0
3.50 3.52 28.2 2.50 3.31
8.00
18.7 3.14 23.5 3.22 29.3 3.26 30.5 3.22 47.2 3.63
YMA04811
N1AHD20 G2FD060(S,H)24(T) 48.0
3.66 3.84 31.0 2.52 3.60
8.00
19.7 3.44 25.3 3.52 33.6 3.59 36.1 3.57 53.7 3.94
N1AHD20 G2FD061H24
48.0
3.66 3.84 31.0 2.52 3.60
8.00
19.7 3.45 25.4 3.53 33.7 3.60 36.3 3.58 53.9 3.95
YMA06011
N1AHD20
G2FD060(S,H)24(T) 59.0 3.72 4.65 36.2 2.58 4.11 8.00 21.0 3.75 28.6 3.93 38.9 4.14 41.5 4.18 66.6 4.83
N1AHD20
G2FD061H24
59.0 3.72 4.65 36.2 2.58 4.11 8.00 21.0 3.75 28.6 3.93 38.9 4.14 41.5 4.18 66.6 4.83
1 PH 12 SEER WITH N1VS - VARIABLE SPEED
YMA02411
N1VSB12 G2FD030(S,H)17(T) 23.4
3.70 1.85 13.3 2.64
1.48
8.50
6.5
1.23
9.9
1.36 15.4 1.55 17.4 1.62 26.9 1.98
YMA03011
N1VSB12 G2FD030(S,H)17(T) 29.4
3.46 2.49 17.5 2.60
1.97
8.50
9.6
1.63 13.6 1.81 20.1 2.10 22.6 2.22 33.5 2.67
YMA03611
N1VSB12 G2FD036(S,H)17(T) 34.8
3.70 2.76 20.6 2.68
2.25
8.50
11.3 1.95 16.1 2.12 23.0 2.38 25.2 2.48 39.7 2.94
N1VSC16 G2FD036(S,H)21(T) 34.8
3.76 2.71 20.6 2.72
2.22
8.50
11.2 1.90 15.9 2.06 22.9 2.32 25.1 2.42 39.6 2.88
YMA04211
N1VSC16 G2FD048(S,H)21(T) 41.0
3.64 3.30 27.2 2.60
3.07
8.50
17.9 2.92 22.6 3.00 28.4 3.04 29.5 3.00 45.9 3.39
N1VSD20 G2FD048(S,H)24(T) 41.0
3.68 3.26 27.4 2.62
3.06
8.50
18.1 2.91 22.8 2.99 28.5 3.03 29.7 2.99 46.1 3.38
YMA04811
N1VSD20 G2FD060(S,H)24(T) 47.0
3.82 3.60 30.2 2.60
3.40
8.50
19.0 3.27 24.6 3.37 32.8 3.38 35.3 3.35 52.6 3.67
N1VSD20 G2FD061H24
47.5
3.80 3.70 30.8 2.64
3.42
8.50
19.5 3.27 25.2 3.36 33.5 3.42 36.0 3.41 53.7 3.78
YMA06011
N1VSD20
G2FD060(S,H)24 58.5 3.74 4.58 35.6 2.60 4.01 8.00 20.3 3.63 28.0 3.82 38.3 4.06 41.0 4.10 66.1 4.77
N1VSD20
G2FD061H24
58.5 3.74 4.58 35.6 2.60 4.01 8.00 20.3 3.63 28.0 3.82 38.3 4.06 41.0 4.10 66.1 4.77
1 PH 12 SEER HP / F2RP / RC / FP / FC /FV
YMA02411
F2RC/F2FC036 -
24.0
3.46 2.03 13.8 2.44 1.66
8.00
7.0
1.41 10.4 1.53 15.9 1.73 17.9 1.79 27.4 2.16
F2RP/F2FP/F3FP024
-
23.6
3.46 2.00 13.4 2.44 1.61
8.00
7.0
1.41 10.4 1.53 15.9 1.73 17.9 1.79 27.4 2.16
F2RP/F2FP/F3FP030
-
24.0
3.46 2.03 13.8 2.44 1.66
8.00
7.0
1.41 10.4 1.53 15.9 1.73 17.9 1.79 27.4 2.16
YMA03011
F2RC/F2FC036
-
30.0
3.30 2.66 17.6 2.42 2.13
8.00
9.4
1.80 13.6 1.97 20.2 2.26 22.7 2.38 34.2 2.84
F2RP/F2FP/F3FP030
-
30.0
3.32 2.65 17.6 2.42 2.13
8.00
9.4
1.80 13.6 1.97 20.2 2.26 22.7 2.38 34.2 2.83
YMA03611
F2FP/F3FP040
-
35.0
3.54 2.90 20.8 2.54 2.40
8.00
11.5 2.09 16.2 2.26 23.2 2.52 25.4 2.61 39.9 3.07
F2RP/F2FP/F3FP036
-
34.8
3.52 2.90 20.6 2.50 2.41
8.00
11.2 2.09 15.9 2.26 22.9 2.52 25.1 2.61 39.6 3.07
F2RP/F2FP/F3FP042
-
35.0
3.54 2.90 20.8 2.54 2.40
8.00
11.5 2.09 16.2 2.26 23.2 2.52 25.4 2.61 39.9 3.07
YMA04211
F2FP048
-
41.5
3.46 3.51 27.8 2.48 3.28
8.00
18.7 3.14 23.3 3.22 29.1 3.26 30.2 3.22 46.6 3.63
F2FP/F3FP060
-
47.5
3.58 3.89 30.8 2.48 3.64
8.00
19.6 3.46 25.2 3.55 33.4 3.62 35.9 3.60 53.4 3.99
YMA04811
F2FP045
-
47.5
3.68 3.78 30.8 2.54 3.55
8.00
19.6 3.46 25.2 3.55 33.4 3.62 35.9 3.60 53.4 3.99
F2FV060
-
47.0
3.82 3.60 30.2 2.60 3.40
8.50
19.0 3.27 24.6 3.37 32.8 3.38 35.3 3.35 52.6 3.67
YMA06011
F2FP060
-
59.0 3.72 4.65 36.2 2.58 4.11 8.00 21.0 3.75 28.6 3.93 38.9 4.14 41.5 4.18 66.6 4.83
F2FV060
-
58.5 3.74 4.58 35.6 2.60 4.01 8.00 20.3 3.63 28.0 3.82 38.3 4.06 41.0 4.10 66.1 4.77
1
Rated CFM same as for cooling.
2
Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental
electric heat operation.
3
Integrated heating capacities include the effect of defrost cycles in the temperature range where they occur.