background image

JOHNSON CONTROLS

26

FORM 160.75-N3 

ISSUE DATE: 04/15/2019

SECTION 1 - SHIPPING AND REASSEMBLY

P8-P9 AND H9 CCOMPRESSORS 

(SYSTEM PIPING)

SUCTION 

LINE

3/8”

OIL

RETURN

 LINE

3/8”

OIL

RETURN

 LINE

3/8”

COMPRESSOR

TO

VSOP

PANEL

3/4”

OIL

RETURN

 LINE

3/4”

OIL

SUPPLY

 LINE

FIGURE 18 - 

SYSTEM PIPING (P8-P9 AND H9 COMPRESSORS)

LD13174

Содержание YK

Страница 1: ...ERS STYLE G R 134a OR R 513A COOLING ONLY WITH GRAPHIC CONTROL CENTER FOR ELECTROMECHANICAL STARTER SOLID STATE STARTER AND VARIABLE SPEED DRIVE CENTRIFUGAL LIQUID CHILLERS INSTALLATION INSTRUCTIONS S...

Страница 2: ...this document and any referenced materials This in dividual shall also be familiar with and comply with all applicable industry and governmental standards and regulations pertaining to the task in que...

Страница 3: ...unted MV SSS Manufactured Before 2007 160 00 O5 Operation Floor Mounted MV SSS Manufactured After 2007 160 00 O5 1 Operation Unit Mounted MV SSS 160 00 O7 Operation MV VSD 2300 VAC 6600 VAC 160 00 O6...

Страница 4: ...04 15 2019 NOMENCLATURE YK KC K4 H9 CY G MOTOR CODE POWER SUPPLY for 60 Hz 5 for 50 Hz COMPRESSOR CODE CONDENSER CODE EVAPORATOR CODE MODEL STYLE Design Level Refer to YK Engineering Guide Form 160 75...

Страница 5: ...amage Shortage 8 Data Plates 9 Long Term Storage 9 Reassembly 11 Q3 Q7 and P7 Compressors Without Falling Film 14 Q3 Q7 and P7 Compressors with Falling Film 16 Q3 Q7 and P7 Compressors System Piping 1...

Страница 6: ...3 Q7 And P7 Compressors With Falling Film 16 FIGURE 9 Form 7 Shipment Q3 Q7 And P7 Compressors With Falling Film 17 FIGURE 10 System Piping Q3 Q7 And P7 Compressors 18 FIGURE 11 Form 3 Shipment K Comp...

Страница 7: ...with dry ni trogen 2 to 3 PSIG The shipment may include miscellaneous packaging of the control center oil eductor filter tubing water temperature controls wiring oil isolators solid state starter or v...

Страница 8: ...2 psig to 3 psig Miscellaneous packaging of tubing water temperature controls wiring isolators etc The unit is shipped with a nitrogen charge The refrigerant charge is shipped in appropriate cylinder...

Страница 9: ...f material under pres sure and to protect themselves 1 Check that the working space is open and has good ventilation If is does not have good ventila tion connect a hose or pipe to the valve Item 5 an...

Страница 10: ...5 6 7 Nozzle without flanges Lines 4 in through 12 in Nozzle without flanges Lines 14 in through 24 in 8 9 8 9 ITEM DESCRIPTION 1 Tag Warning Dennison 8E 2 Gauge Press 2 Dia 0 30 3 Tag GlvSt Wire Spee...

Страница 11: ...onnection Check the transverse alignment by placing a level on the tops of both end sheets Refer to the Installation Unit Form 160 75 N1 for additional instructions to level the unit After shell is le...

Страница 12: ...placing a level on the tops of both end sheets refer to Installation Unit Form 160 75 N1 for additional instructions to level the unit After shell is leveled wedge and shim each corner of the shell t...

Страница 13: ...unted MV SSS Form 160 75 PW2 7 Reconnect all unit wiring and harnesses refer to Wiring Diagrams Field Connections Remote Mounted MV SSS Form 160 75 PW2 8 Pressure test the unit Relief valves must be p...

Страница 14: ...Q7 AND P7 COMPRESSORS WITHOUT FALLING FILM LD13170 SUCTION LINE DISCHARGE LINE DISCHARGE ISOLATION VALVE IF FURNISHED HOT GAS VALVE IF FURNISHED RING GASKETS See NOTE CONDENSER EVAPORATOR Q3 Q7 AND P...

Страница 15: ...Q3 Q7 AND P7 COMPRESSORS WITHOUT FALLING FILM CONDENSER EVAPORATOR SUCTION LINE ISOLATION VALVE IF FURNISHED HOT GAS VALVE IF FURNISHED LIQUID LINE VALVE IF FURNISHED RING GASKETS See NOTE Q3 Q7 AND...

Страница 16: ...ON VALVE IF FURNISHED HOT GAS VALVE IF FURNISHED RING GASKETS See NOTE CONDENSER EVAPORATOR LD13171b CONDENSER EVAPORATOR LIQUID LINE LD13170a Figure 8 FORM 3 SHIPMENT Q3 Q7 AND P7 COMPRESSORS WITH FA...

Страница 17: ...NISHED HOT GAS VALVE IF FURNISHED RING GASKETS See NOTE CONDENSER EVAPORATOR LD13171b Figure 9 FORM 7 SHIPMENT Q3 Q7 AND P7 COMPRESSORS WITH FALLING FILM Q3 Q7 AND P7 COMPRESSORS CONT D WITH FALLING F...

Страница 18: ...19 Section 1 Shipping and Reassembly LD13174 Figure 10 SYSTEM PIPING Q3 Q7 AND P7 COMPRESSORS Q3 Q7 AND P7 COMPRESSORS SYSTEM PIPING SUCTION LINE 3 8 OIL RETURN LINE 3 8 OIL RETURN LINE 3 8 COMPRESSOR...

Страница 19: ...FORM 3 SHIPMENT K COMPRESSORS LD13172 Ring Gaskets See NOTE DISCHARGE SPOOL ISOLATION VALVE IF FURNISHED SUCTION LINE HOT GAS VALVE IF FURNISHED OIL LINE OIL PUMP PANEL CONTROL PANEL CONDENSER EVAPOR...

Страница 20: ...gure 12 FORM 7 SHIPMENT K COMPRESSORS LD13173 CONDENSER EVAPORATOR HOT GAS IF FURNISHED LIQUID LINE OIL LINE RING GASKETS See NOTE DISCHARGE SPOOL SUCTION LINE ISOLATION VALVE IF FURNISHED K COMPRESSO...

Страница 21: ...ng and Reassembly FORM 160 75 N3 ISSUE DATE 04 15 2019 1 LD13175 Figure 13 SYSTEM PIPING K COMPRESSORS K COMPRESSORS CONT D 3 4 OIL SUPPLY LINE 1 OIL SUMP VENT LINE 3 8 LIQUID INJECTION LINE 1 REFRIGE...

Страница 22: ...P9 AND H9 COMPRESSORS WITHOUT FALLING FILM SUCTION LINE DISCHARGE SPOOL ISOLATION VALVE IF FURNISHED HOT GAS VALVE IF FURNISHED OIL PUMP PANEL CONTROL PANEL CONDENSER EVAPORATOR RING GASKETS See NOTE...

Страница 23: ...WITHOUT FALLING FILM SUCTION LINE DISCHARGE SPOOL DISCHARGE ISOLATION VALVE IF FURNISHED HOT GAS VALVE IF FURNISHED LIQUID LINE VALVE CONTROL PANEL OIL PUMP CONTROL PANEL RING GASKETS See NOTE CONDEN...

Страница 24: ...M P8 P9 AND H9 COMPRESSORS WITH FALLING FILM FROM CONDENSER TO EVAPORATOR LIQUID LINE LIQUID LINE FROM CONDENSER TO EVAPORATOR DISCHARGE SPOOL SUCTION LINE ISOLATION VALVE IF FURNISHED HOT GAS VALVE I...

Страница 25: ...ATOR SUCTION LINE DISCHARGE SPOOL DISCHARGE ISOLATION VALVE IF FURNISHED HOT GAS VALVE IF FURNISHED CONTROL PANEL OIL PUMP CONTROL PANEL RING GASKETS See NOTE LD13185b Figure 17 FORM 7 SHIPMENT P8 P9...

Страница 26: ...9 Section 1 Shipping and Reassembly P8 P9 AND H9 CCOMPRESSORS SYSTEM PIPING SUCTION LINE 3 8 OIL RETURN LINE 3 8 OIL RETURN LINE 3 8 COMPRESSOR TO VSOP PANEL 3 4 OIL RETURN LINE 3 4 OIL SUPPLY LINE Fi...

Страница 27: ...elsius multiply by 5 9 or 0 5556 Example 10 0 F range x 0 5556 5 6 C range Table 1 SI METRIC CONVERSION MEASUREMENT MULTIPLY ENGLISH UNIT BY FACTOR TO OBTAIN METRIC UNIT Capacity Tons Refrigerant Effe...

Страница 28: ...Pennsylvania USA 17349 1 800 524 1330 Subject to change without notice Printed in USA Copyright by Johnson Controls 2019 www johnsoncontrols com ALL RIGHTS RESERVED Form 160 75 N3 419 Issue Date Apri...

Отзывы: