12
1
2
3
4
5
No. Typ e
Contents
LE D L amp flash
R emarks
Mode conflict
Water level switch is
abnormal
Malfun-
ction
Malfun-
ction
Malfun-
ction
Malfun-
ction
Alarm
The e vaporator s ensor
check point is ab nomal ,
or ro om temp.se nsor is
abnormal.
R un lamp flashes
at 2.5Hz.
After the malfunctions
disappear, it restores
automatically.
Indoor/outdoor unit com-
munication is abnormal.
The timer lamp fla-
shes at 2. 5Hz.
Condenser sensor check
point is abnormal or outdoor
temp. sensor is abnormal.
All the indoor alarm
lamps flash at 0.5Hz.
After the malfunctions
disa ppea r, it res tores
automatically.
If the malfunctions can t
be solved in three min.
all the indoor alarm
lamps flash at 0.5Hz.
Turn off the power to restore.
Alarm lamp flashes
at 2.5Hz.
Defrost lamp
flashes at 2.5Hz.
When the indoor unit turns
to heating mode or is turned
off, the alarm will disappear.
Run lamp
Timer lamp
Defrost lamp
Alarm lamp
Manual Switch
TROUBLESHOOTING
After the malfunctions
disappear, it restores
automatically.