![York YCUL0016 Скачать руководство пользователя страница 111](http://html1.mh-extra.com/html/york/ycul0016/ycul0016_user-manual_4222353111.webp)
YORK INTERNATIONAL
110
YORK INTERNATIONAL
111
FORM 150.63-EG1
SYSTEM #1 COMPRESSOR & FAN
SYSTEM #2 FIELD SUPPLIED WIRING
COMPR. #1
COMPR. #2
COMPR. #3
FANS
COMPR. #1
COMPR. #2
COMPR. #3
FANS
RLA
LRA
RLA
LRA
RLA
LRA
QTY
FLA(EA)
RLA
LRA
RLA
LRA
RLA
LRA
QTY
FLA(EA)
100.2
550
100.2
550
—
—
3
8.2
73.9
450
73.9
450
—
—
3
8.2
92.8
550
92.8
550
—
—
3
7.8
68.5
450
68.5
450
—
—
3
7.8
53.5
305
53.5
305
—
—
3
4.8
39.5
260
39.5
260
—
—
3
4.8
44.2
270
44.2
270
—
—
3
4.0
32.6
215
32.6
215
—
—
3
4.0
35.4
210
35.4
210
—
—
3
3.1
26.1
180
26.1
180
—
—
3
3.1
100.2
550
100.2
550
—
—
3
8.2
100.2
550
100.2
550
—
—
3
8.2
92.8
550
92.8
550
—
—
3
7.8
92.8
550
92.8
550
—
—
3
7.8
53.5
305
53.5
305
—
—
3
4.8
53.5
305
53.5
305
—
—
3
4.8
44.2
270
44.2
270
—
—
3
4.0
44.2
270
44.2
270
—
—
3
4.0
35.4
210
35.4
210
—
—
3
3.1
35.4
210
35.4
210
—
—
3
3.1
73.9
450
73.9
450
73.9
450
4
8.2
100.2
550
100.2
550
—
—
4
8.2
68.5
450
68.5
450
68.5
450
4
7.8
92.8
550
92.8
550
—
—
4
7.8
39.5
260
39.5
260
39.5
260
4
4.8
53.5
305
53.5
305
—
—
4
4.8
32.6
215
32.6
215
32.6
215
4
4.0
44.2
270
44.2
270
—
—
4
4.0
26.1
180
26.1
180
26.1
180
4
3.1
35.4
210
35.4
210
—
—
4
3.1
73.9
450
73.9
450
73.9
450
4
8.2
73.9
450
73.9
450
73.9
450
4
8.2
68.5
450
68.5
450
68.5
450
4
7.8
68.5
450
68.5
450
68.5
450
4
7.8
39.5
260
39.5
260
39.5
260
4
4.8
39.5
260
39.5
260
39.5
260
4
4.8
32.6
215
32.6
215
32.6
215
4
4.0
32.6
215
32.6
215
32.6
215
4
4.0
26.1
180
26.1
180
26.1
180
4
3.1
26.1
180
26.1
180
26.1
180
4
3.1
100.2
550
100.2
550
100.2
550
4
8.2
73.9
450
73.9
450
73.9
450
4
8.2
92.8
550
92.8
550
92.8
550
4
7.8
68.5
450
68.5
450
68.5
450
4
7.8
53.5
305
53.5
305
53.5
305
4
4.8
39.5
260
39.5
260
39.5
260
4
4.8
44.2
270
44.2
270
44.2
270
4
4.0
32.6
215
32.6
215
32.6
215
4
4.0
35.4
210
35.4
210
35.4
210
4
3.1
26.1
180
26.1
180
26.1
180
4
3.1
YCUL0096 - YCUL0130 (R22 & R407C)
SINGLE-POINT POWER SUPPLY CONNECTIONS WITH INDIVIDUAL SYSTEM CIRCUIT BREAKERS (see Fig. 4)
(One Field Provided Power Supply Circuit to the condensing unit. Field connections to Factory Provided Terminal Block (optional) or Non-Fused Disconnect Switch
(optional). Includes Individual Branch Circuit Protection (Breakers) per electrical system)