York YAFS012 Скачать руководство пользователя страница 53

Contractor:  

P.O.:

 

Engineer:

Project Name: 

Unit Tag:

The manufacturer works continually to improve its products. As a result, the design and speci

fi

 cations of each product at the time of order may be changed without notice. Purchaser’s approval of this data set signi

fi

 es that the equipment is acceptable under the provisions 

of the job speci

fi

 cation.  Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely the manufacturer’s opinion or commendation of its products. York and Af

fi

 nity are registered 

trademarks of Johnson Controls, Inc., and are used with permission.

C

DESCRIPTION

SW2-4

SW2-5

Cycle with Blower

ON

ON

Cycle with Compressor

OFF

OFF

Water Valve Slow Opening

ON

OFF

Cycle with Comm. T-stat Hum Cmd

OFF

ON

ABC SW2 Accessory Relay

Current Transducer (CT)

Thermistor

Light  emitting diode - Green

Relay coil

Capacitor w/ bleed resistor

Switch - Condensate overflow

Switch - High pressure

Switch - Low pressure

Polarized connector

Factory  Low voltage wiring
Factory Line voltage wiring

Field low voltage wiring

Field line voltage  wiring

Optional block

DC Voltage PCB traces
Junction
Quick connect   terminal

Wire nut

Field wire  lug

Ground

Fuse

CC -

CO -
K5 -

K6 -

CR3 -

CR4 - 

F1 and F2 - 

WCL -

HE -
HP - 

LP -

PB1, PB2 - 

PS -

RV -
SW1 -

SW1 -

SW2 -

TS - 

Compressor Contactor

Condensate overflow sensor
DHW pump relay

Loop pump relay

Fuses

Water Coil Limit Sensor

Heater element
High pressure switch

Low  pressure switch

Power blocks

Power strip

Reversing Valve coil
DIP package 5 position AXB

TEST MODE ABC Board

DIP  package 8 position ABC Board

Thermal limit switch

Legend

Relay Contacts-

N.O., N.C.

G

T

1

3

2

P

L1

PSC Fan Speed Relay

PSC Fan Power Relay

ER1 to ER4 -

Aux heat stage relays

HWL -

Hot water limit sensor

SC -

Start Contactor

Start Relay

SR -

CS -

Compressor Solenoid

Breaker

Aurora LED Flash Codes

Status LED  (LED3, Green)

Status LED (LED1, Green)
Configuration LED (LED2, Yellow)
Fault LED (LED3, Red)

Random Start Delay (Alternating Colors)

Fast Flash
Fast Flash
Fast Flash

1 second on  and 1 second off
100 milliseconds on  and 100 milliseconds off
100 milliseconds on and 400 milliseconds off with a 2 second pause before repeating

Slow Flash
Fast Flash
Flash Code

Normal Mode
Control is  Non-Functional
Test Mode
Lockout Active
Dehumidification Mode
Future Use
Future Use
Load Shed
ESD

OFF

ON

Slow Flash

Fast Flash

Flash Code 2
Flash Code 3

Flash Code 6

Flash Code 4
Flash Code 5

Future Use

Flash Code 7

Configuration LED  (LED2, Yellow)

No Software Overide

OFF

DIP Switch Overide

Slow Flash

Fault LED (LED1, Red)

Normal Mode
Input Fault Lockout
High Pressure Lockout
Low Pressure Lockout
Future Use
Freeze Detection – FP1
Reserved
Condensate Overflow Lockout
Over/Under Voltage Shutdown
Future Use
Future Use
FP1 Sensor Error

Flash Code 1

OFF

Flash Code 2
Flash Code 3
Flash Code 4
Flash Code 5

Flash Code 8

Flash Code 6
Flash Code 7

Flash Code 9

Flash Code 10
Flash Code 11

2

3

P9

5
4

1

L2

L1

L2

L1

Green

P11

2

3

4

5

1

Violet

Blue

Brown

Orange

HE1

TS1

HE3

TS3

HE2

TS2

HE4

TS4

Connects to variable 

speed ECM motor  only

60 AMP  

BRK1

60 AMP  

BRK2

G

G

K1

K2

K3

K4

NO

NO

NO

NO

EA Series 

PCB 

P2

4

1

2 3

C

G

G

G

G

K5

NO

K6

NO

K7

NO

K8

NO

Gray

Yellow

Gray

Yellow

Black

Pink

Black

Pink

Pink

Pink

Gray

Black

Yellow

Gray

Black

Yellow

4

1

2 3

C

P1

COM

COM

COM

COM

COM

COM

COM

COM

Aux heat staging

FB1

FB2

FB3

FB4

 P3 on Aurora ABC Board

P3

EH2

C EH1 C

CO

Light  emitting diode - Green

Polarized connector

Factory  Low voltage wiring

Factory Line voltage wiring
Field low voltage wiring

Field line voltage  wiring

Optional block

DC Voltage PCB traces
Internal junction

Quick connect   terminal

Thermal Limit Switch

Field wire lug

Ground

HE -

PB - 

Heater element

Power block

Legend

N.O., N.C.

G

L1

Breaker

1 2 3

P

TS

Electric Heat  Relay

K*

Fused Backup

FB

2 - Use manufacturer’s part number 19P592-01 (jumper 

bar assembly) when  single source power  is required. 

1 - Use copper or  aluminum conductors.

3 – Jumpers wires are Factory Installed, and are

required  for a uxiliary heat operation.

  

4 – Low voltage wiring CLASS 2.

 NOTE 3

With optional EA Series 20kW Auxiliary Electric Heat Shown

Wiring Schematics cont.

Aurora Base with ECM, IntelliStart and UPC cont.

Affinity & Affinity Advanced Series

1 - 6 Tons 60Hz

SD2500AK6      11/22 

53 

Page _____ of _____

Содержание YAFS012

Страница 1: ...NOMINAL TONS Due to continuous product improvement specifications are subject to change without notice Visit us on the web at www york geothermal com Additional rating information can found at www ahr...

Страница 2: ...tory Installed Pump No IntelliStart1 3 No HWG IntelliStart1 4 HWG with Factory Installed Pump IntelliStart1 Vintage Factory Use Only Controls D Aurora Performance and Refrigeration Package Air Coil Op...

Страница 3: ...2 000 6 1 22 200 29 7 17 500 4 9 21 000 26 0 16 400 4 5 038 Full 9 1300 36 500 17 0 43 300 5 5 40 000 24 4 35 000 4 9 38 200 19 7 28 500 4 2 038 Part 8 1150 26 500 19 0 31 300 6 4 29 900 32 1 24 900 5...

Страница 4: ...on AHRI ISO 13256 1 Performance Ratings cont Affinity Affinity Advanced Series 1 6 Tons 60Hz SD2500AK6 11 22 4 Page _____ of _____ Cooling capacities based upon 80 6 F DB 66 2 F WB entering air temper...

Страница 5: ...es 1 6 Tons 60Hz SD2500AK6 11 22 5 Page _____ of _____ Energy Star Rating Criteria In order for water source heat pumps to be Energy Star rated they must meet or exceed the minimum efficiency requirem...

Страница 6: ...5 34 0 41 7 24 4 17 5 23 9 29 7 16 0 1 8 35 6 35 6 6 9 5 8 55 9 45 7 5 1 022 030 in 22 5 26 5 48 5 2 0 7 0 13 5 16 5 10 2 1 in Swivel 1 2 in Female 9 5 12 1 14 3 6 1 0 8 14 0 14 0 4 4 1 7 22 2 26 0 1...

Страница 7: ...ate Supply Width Supply Depth Return Depth Return Height 022 030 in 22 5 26 5 52 5 35 3 40 2 46 7 49 7 3 6 1 in Swivel 1 2 in Female 41 9 43 6 45 1 8 6 6 0 9 3 10 5 1 0 2 2 22 2 26 0 5 6 cm 57 2 67 3...

Страница 8: ...ate Power Supply Ext Pump Low Voltage Supply Width Supply Depth Return Depth Return Height 042 049 in 25 6 31 6 54 4 2 3 7 3 15 9 18 9 10 6 1 Swivel 1 2 female 9 5 12 1 14 3 13 3 13 6 39 4 9 1 8 1 1 7...

Страница 9: ...11 7 1 8 10 5 9 5 8 2 2 2 21 8 16 5 1 5 cm 57 2 134 6 49 0 5 8 13 5 35 1 42 7 20 3 17 5 24 1 29 7 4 6 26 7 24 1 20 8 5 6 55 4 41 9 3 8 022 030 in 22 5 63 0 19 3 2 0 7 0 13 5 16 5 0 8 1 in Swivel 1 2...

Страница 10: ...le Sweat I D in mm n a 1 2 12 7 1 2 12 7 1 2 12 7 1 2 12 7 1 2 12 7 1 2 12 7 1 2 12 7 1 2 12 7 Coax Piping Water Volume gal l 0 35 1 3 0 40 1 5 0 7 2 6 1 0 3 8 1 3 4 9 1 3 4 9 1 6 6 1 1 6 6 1 2 3 8 7...

Страница 11: ...279 x 254 5 Spd ECM 9 x 7 229 x 178 11 x 10 279 x 254 11 x 10 279 x 254 11 x 10 279 x 254 11 x 10 279 x 254 Coax and Water Piping Water Connections Size Swivel in mm 1 25 4 1 25 4 1 25 4 1 25 4 1 25...

Страница 12: ...e 34 7 40 0 53 3 60 0 60 60 60 60 60 60 EAL H 15A Single 52 0 60 0 75 0 85 0 80 90 80 90 70 100 L1 L2 34 7 40 0 53 3 60 0 60 60 60 60 60 60 L3 L4 17 3 20 0 21 7 25 0 25 25 25 25 20 30 EAL H 20A Single...

Страница 13: ...14 1 73 0 26 0 0 4 5 4 4 0 23 9 27 4 40 042 208 230 60 1 187 253 26 0 16 6 79 0 28 0 0 4 5 4 4 0 26 4 30 6 45 048 208 230 60 1 187 253 31 0 19 8 109 0 38 0 0 4 5 4 4 0 29 6 34 6 50 060 208 230 60 1 1...

Страница 14: ...LA LRA LRA 026 208 230 60 1 187 253 18 2 11 6 58 3 21 0 0 4 5 4 4 0 21 4 24 4 35 038 208 230 60 1 187 253 23 8 15 2 83 0 30 0 0 4 5 4 4 0 25 0 28 8 40 049 208 230 60 1 187 253 33 0 21 1 104 0 37 0 0 4...

Страница 15: ...0 75 800 950 1100 1300 1500 1750 1950 2100 2300 2325 G L H Aux 070 0 75 800 950 1100 1300 1500 1750 1950 2100 2300 2325 G L H Aux Factory settings are at recommended G L H Aux speed settings L H setti...

Страница 16: ...2 Med Low 2 Y1 1575 1560 1540 1520 1502 1487 1471 1448 1424 1409 1393 1351 1308 1266 Low 1 G 1454 1406 1358 1333 1308 1285 1261 1239 1217 1198 1179 1072 1002 988 048 High 5 11 x 10 1 1934 1910 1886 18...

Страница 17: ...1659 1617 Med High 4 1799 1783 1767 1744 1720 1693 1666 1649 1631 1617 1603 1560 1530 1492 Med 3 Y2 1694 1680 1666 1642 1617 1592 1567 1552 1537 1519 1500 1453 1421 1372 Med Low 2 Y1 1575 1560 1540 1...

Страница 18: ...r Performance Data cont Affinity Affinity Advanced Series 1 6 Tons 60Hz SD2500AK6 11 22 18 Page _____ of _____ Unit with Standard PSC Motor Model Motor Spd Blower Size Motor HP Airflow cfm at External...

Страница 19: ...6 66 2 27 19 68 20 0 Max Entering Air db wb 110 83 43 28 3 80 26 7 Water Limits Min Entering Water 30 1 1 20 6 7 Normal Entering Water 50 110 10 43 3 30 70 1 1 Max Entering Water 120 48 9 90 32 2 NOTE...

Страница 20: ...987 1 018 475 119 1 017 1 099 1 037 1 022 1 018 0 984 1 025 500 125 1 020 1 132 1 052 1 027 1 022 0 982 1 031 520 130 1 022 1 159 1 064 1 030 1 025 0 979 1 034 5 30 06 Air Flow Corrections Dual Capaci...

Страница 21: ...he corrected heating and cooling performance at 30 F and 90 F respectively as well as pressure drop at 30 F for a Affinity Series Single Speed Model 022 ECM The corrected cooling capacity at 90 F woul...

Страница 22: ...1 1 0 1 0 0 9 0 8 9 2 3 2 1 2 0 1 9 1 7 12 3 9 3 7 3 4 3 2 3 0 16 6 7 6 3 5 9 5 5 5 1 060 9 2 4 2 2 2 1 2 0 1 8 12 3 9 3 6 3 4 3 2 2 9 15 5 7 5 3 5 0 4 7 4 3 20 9 5 8 9 8 3 7 8 7 2 070 12 3 0 2 8 2 6...

Страница 23: ...9 50 1 5 0 3 0 7 10 6 0 83 7 8 92 5 3 75 15 0 10 0 0 66 0 61 17 1 24 6 2 5 1 0 2 3 11 0 0 83 8 2 93 5 3 86 15 2 9 9 0 65 0 56 17 1 27 3 3 5 1 7 3 8 11 4 0 84 8 5 94 4 3 97 15 5 9 9 0 64 0 51 17 2 30...

Страница 24: ...94 22 4 20 5 1 1 4 0 2 8 6 6 500 18 8 1 34 14 3 102 9 4 11 2 1 500 18 9 11 4 0 60 0 81 21 7 23 2 1 0 600 19 4 1 37 14 8 98 0 4 16 2 0 600 19 4 12 6 0 65 0 88 22 4 22 2 1 1 5 0 4 1 9 5 500 19 2 1 36 1...

Страница 25: ...0 1 4 4 5 1 6 3 7 600 21 2 1 27 16 9 102 7 4 89 2 4 600 24 8 16 1 0 65 0 88 27 8 28 3 1 2 700 21 8 1 26 17 5 98 8 5 05 2 3 700 25 3 17 5 0 69 0 91 28 5 27 7 1 3 6 0 2 6 6 0 600 21 6 1 29 17 2 103 3 4...

Страница 26: ...23 7 1 8 6 0 2 4 6 4 700 28 9 1 69 23 1 108 2 5 01 3 3 700 29 6 19 1 0 65 1 16 33 5 25 4 1 6 900 29 7 1 69 23 9 100 6 5 16 3 0 900 30 5 21 3 0 70 1 23 34 7 24 7 1 7 8 0 4 0 10 7 700 29 5 1 71 23 6 10...

Страница 27: ...9 4 3 1050 34 5 2 01 27 6 100 4 5 03 4 0 1050 35 4 24 1 0 68 1 40 40 2 25 4 1 9 1250 35 5 2 01 28 6 96 3 5 18 3 7 1250 36 5 27 0 0 74 1 48 41 6 24 7 2 0 9 0 3 1 7 3 1050 35 2 2 04 28 2 101 0 5 06 4 2...

Страница 28: ...4 6 1150 39 2 2 39 31 0 101 6 4 80 5 9 1150 43 0 28 0 0 65 1 70 48 8 25 4 2 8 1350 40 0 2 32 32 1 97 4 5 06 5 4 1350 44 7 31 4 0 70 1 78 50 8 25 1 3 0 11 0 3 9 9 1 1150 40 1 2 41 31 9 102 3 4 87 6 1...

Страница 29: ...8 1300 51 3 3 28 40 1 106 5 4 59 7 8 1300 50 6 32 4 0 64 2 13 57 9 23 7 3 3 1500 52 3 3 18 41 5 102 3 4 83 7 2 1500 52 6 36 4 0 69 2 24 60 2 23 5 3 6 12 0 3 5 8 2 1300 52 5 3 31 41 2 107 4 4 65 8 0 13...

Страница 30: ...9 4 16 50 7 110 0 4 57 9 4 1500 68 7 46 4 0 68 2 93 78 7 23 4 4 4 2000 65 8 4 21 51 4 100 5 4 57 8 7 2000 70 4 49 3 0 70 3 24 81 4 21 7 4 8 15 0 5 2 11 9 1500 66 3 4 23 51 9 110 9 4 59 9 7 1500 69 4 4...

Страница 31: ...5 16 59 5 112 0 4 38 11 2 1700 72 6 47 0 0 65 3 22 83 5 22 6 4 8 2200 79 1 5 12 61 6 103 3 4 53 10 3 2200 76 4 53 8 0 70 3 62 88 8 21 1 5 2 18 0 5 3 12 3 1700 78 0 5 20 60 2 112 5 4 39 11 5 1700 73 5...

Страница 32: ...6 2 96 3 5 37 1 9 700 23 7 16 0 0 68 0 77 26 4 31 0 1 0 5 0 1 8 4 1 500 20 2 1 08 16 5 107 4 5 50 2 1 500 23 3 14 6 0 63 0 73 25 8 31 8 0 9 700 20 7 1 08 17 0 97 3 5 60 2 0 700 24 0 16 1 0 67 0 75 26...

Страница 33: ...8 32 9 22 3 1 6 900 26 8 1 59 21 4 97 6 4 94 2 9 900 29 9 19 9 0 67 1 34 34 4 22 3 1 7 6 0 2 5 5 8 700 27 2 1 63 21 6 105 9 4 90 3 2 700 29 2 18 1 0 62 1 22 33 3 24 0 1 5 900 28 1 1 64 22 5 98 9 5 02...

Страница 34: ...1 3 1050 28 8 1 68 23 1 95 4 5 03 2 6 1050 31 3 23 1 0 74 1 06 35 0 29 7 1 4 6 0 1 5 3 6 900 29 3 1 67 23 6 100 1 5 15 3 0 900 30 8 21 0 0 68 1 01 34 2 30 5 1 3 1050 29 9 1 68 24 2 96 4 5 24 2 7 1050...

Страница 35: ...1250 40 0 2 48 31 5 99 6 4 72 3 8 1250 41 3 28 7 0 70 2 09 48 4 19 8 2 4 7 0 2 0 4 6 1050 40 5 2 54 31 8 105 7 4 68 4 3 1050 40 4 26 1 0 65 1 90 46 8 21 3 2 2 1250 41 8 2 55 33 1 100 9 4 80 4 0 1250 4...

Страница 36: ...50 34 9 2 22 27 3 93 9 4 61 4 8 1350 40 7 27 5 0 67 1 76 46 8 23 1 2 4 8 0 1 8 4 0 1150 36 5 2 29 28 6 99 3 4 67 5 4 1150 40 2 23 5 0 59 1 50 45 3 26 8 2 1 1350 37 9 2 26 30 2 96 0 4 91 5 0 1350 41 4...

Страница 37: ...0 3 24 36 9 98 7 4 34 7 0 1550 54 1 34 3 0 63 2 90 64 0 18 7 3 9 9 0 2 2 5 0 1350 50 1 3 34 38 7 104 4 4 40 7 8 1350 53 4 29 3 0 55 2 47 61 8 21 6 3 4 1550 52 1 3 30 40 8 101 1 4 62 7 2 1550 55 0 34 5...

Страница 38: ...7 6 2 89 37 8 99 4 4 84 5 7 1500 53 0 33 7 0 64 2 06 60 0 25 8 3 0 10 0 2 4 5 5 1250 48 1 2 96 38 0 105 6 4 76 6 3 1250 51 6 30 1 0 58 1 90 58 1 27 2 2 6 1500 48 9 2 92 38 9 100 2 4 90 5 8 1500 53 2 3...

Страница 39: ...0 2 103 2 4 52 8 0 1800 70 0 45 9 0 66 3 51 81 9 19 9 5 1 12 0 3 4 7 8 1500 66 0 4 18 51 7 110 7 4 62 9 0 1500 68 9 42 6 0 62 3 23 79 9 21 3 4 5 1800 67 4 4 24 53 0 104 7 4 66 8 3 1800 70 7 46 3 0 66...

Страница 40: ...0 4 02 48 3 103 8 4 52 6 9 1700 59 8 41 3 0 69 2 66 68 9 22 5 3 4 13 0 3 2 7 3 1400 61 1 4 15 47 0 110 4 4 32 7 7 1400 58 3 36 9 0 63 2 46 66 7 23 7 3 0 1700 63 6 4 07 49 7 104 6 4 57 7 1 1700 60 1 4...

Страница 41: ...5 4 24 10 3 2200 75 5 52 0 0 69 4 26 90 1 17 7 5 6 15 0 4 1 9 6 1850 80 6 5 49 61 9 110 3 4 30 11 5 1850 74 7 48 6 0 65 3 93 88 1 19 0 4 9 2200 83 2 5 58 64 2 105 0 4 37 10 6 2200 76 2 52 5 0 69 4 17...

Страница 42: ...ABC STEPPER ANA ACC2 DH DIV NO COM K6 NO COM K5 C R L1 L1 L2 L2 P12 P10 P5 P11 C R C R C R P4 P2 K1 K2 K3 HA2 HA1 SGI LOOP VS DATA VS PUMP PUMP SLAVE P3 V C R TX RX 5 P14 LLT P1 LAT FLOW LWT EWT CT1 4...

Страница 43: ...er Refer to EAS EAM EAL Auxiliary Heat kit installation instructions 1 Switch blue and red wires for 208V operation 2 The blk wh and gray wh wires are removed when Aux Heatis installed 7 Wires provide...

Страница 44: ...ration LED LED 2 Yellow Fault LED LED 1 Red Normal Mode Dehumidification Mode Flash Code 2 DIP Switch Overide Slow Flash Status LED LED 3 Green Normal Mode ON Control is Non Functional OFF Test Mode S...

Страница 45: ...sing Valve 2nd Stage Compressor 1st StageCompressor Y1 Y2 O R C LO ABC Board G G Fan W W Auxil iary HeatR ela y Note 11 Fiel di nstalled SPST dual fuel rel ay Required for dual fuel i nstallation Auxi...

Страница 46: ...ATA VS PUMP PUMP SLAVE P3 V C R TX RX 5 P14 LLT P1 LAT FLOW LWT EWT COMP1 4 3 FAN 4 3 COMP2 2 1 AUX 2 1 Status G DISCH P16 P17 P18 P15 Aurora Expansion Board AXB Aurora Expansion Board AXB SeeFigure1...

Страница 47: ...gle Speed units Wire is secured at blower 6 Wires provided for Auxiliary Heatlow voltage control Wires are secured at blower 7 Brown blower power wire routed through CurrentTransducer two times 8 Fiel...

Страница 48: ...D Flash Codes 1 second on and 1 second off No Software Overide OFF 100 milliseconds on and 100 milliseconds off 100 milliseconds on and 400 milliseconds off with a 2 second pause before repeating Rand...

Страница 49: ...ostat Dual Fuel Wiring Diagram Using Field Installed Relay 24VDC R from Fossil Fuel Furnace To Fossil Fuel FurnaceW input EH1 C ABC Board Note 11 Fiel di nstalled SPST dual fuel rel ay Required for du...

Страница 50: ...OTE4 NOTE6 Water Solenoid see Open Loop Groundwater Systems section UNIT 12 18 22 30 36 42 48 60 70 UNIT 22 30 36 42 48 M M H M M H M M M M HIGH STATIC PSC FACTORY SET FAN SPEED M M STANDARD PSC M M C...

Страница 51: ...Flash Flash Code Normal Mode Control is Non Functional Test Mode Lockout Active Dehumidification Mode FutureUse FutureUse Load Shed ESD OFF ON SlowFlash Fast Flash Flash Code 2 Flash Code 3 Flash Code...

Страница 52: ...Switch Run Winding Active Start Common IntelliStart Red Pink Black Blue NOTE6 CC2 Factory Fault ALG ALM LS ES ACC c Status AURORA BASE CONTROL RV K1 CC2 CC K2 CCHi K3 Fan K4 Alarm K5 Acc K6 ACC no AC...

Страница 53: ...h 1 secondon and 1 secondoff 100 milliseconds on and 100 milliseconds off 100 milliseconds on and 400 milliseconds off witha 2 secondpause before repeating SlowFlash Fast Flash Flash Code Normal Mode...

Страница 54: ...5 P11 C R C R C R P4 P2 K1 K2 K3 HA2 HA1 SGI LOOP VS DATA VS PUMP PUMP SLAVE P3 V C R TX RX 5 P14 LLT P1 LAT FLOW LWT EWT 4 3 CT2 4 3 CT1 2 1 CT1 2 1 Status G DISCH P16 P17 P18 P15 Aurora Expansion Bo...

Страница 55: ...3 4 5 ON OFF FutureUse Acc 2 Dip 4 Acc 2 Dip 5 CT2 SCT P8 MOTOR P6 RS485 P7 ZONE P9 ABC STEPPER ANA ACC2 DH DIV NO COM K6 NO COM K5 C R L1 L1 L2 L2 P12 P10 P5 P11 C R C R C R P4 P2 K1 K2 K3 HA2 HA1 SG...

Страница 56: ...tical units shall be supplied with left or right horizontal air inlet and top bottom 022 072 or rear vertical 042 072 air discharge Horizontal units shall be supplied with left or right air inlet and...

Страница 57: ...Dual Capacity or 2 zones Single Speed shall also be provided with complete fault and information display on the zoning MasterStat A detachable terminal block with screw terminals will be provided for...

Страница 58: ...to any Aurora Advanced Control System including both ABC and AXB to monitor a sump pump The sen sor can be connected to the Aurora Home Automation inputs HA 1 or HA 2 of the AXB board These will each...

Страница 59: ...the equipment is acceptable under the provisions of the job specification Statements and other information contained herein are not express warranties and do not form the basis of any bargain between...

Страница 60: ...not express warranties and do not form the basis of any bargain between the parties but are merely the manufacturer s opinion or commendation of its products York and Affinity are registered trademar...

Отзывы: