413434-LTG-E-0909
Johnson Controls Unitary Products
17
Multipliers for determining the performance with other indoor sections.
NOTE:
For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Continued on next page.
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
TCGF24S41S1
INDOOR COIL MODEL NO.
FC/MC/PC32
CONDENSING
ENTERING AIR
TEMPERATURE
IDCFM
600
800
1000
ID DB (°F)
80
80
75
80
80
80
80
75
80
80
80
80
75
80
80
ID WB (°F)
57
62
62
67
72
57
62
62
67
72
57
62
62
67
72
65
T.C.
21.8 23.8 23.8 25.7 27.7 23.9 25.4 25.3 27.6 29.5 26.1 27.1 26.9 29.4 31.4
S.C.
16.3 16.3 16.3 16.1 14.4 16.3 16.3 16.3 16.2 15.3 16.3 16.3 16.3 16.3 16.2
KW
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2
75
T.C.
21.0 23.0 22.9 24.9 26.8 23.1 24.6 24.4 26.6 28.6 25.3 26.1 25.9 28.4 30.4
S.C.
16.3 16.3 15.8 15.7 13.9 16.3 16.3 16.0 16.0 14.9 16.3 16.3 16.3 16.3 15.9
KW
1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4
85
T.C.
20.2 22.2 22.0 24.1 25.9 22.4 23.7 23.5 25.7 27.7 24.5 25.2 24.9 27.3 29.5
S.C.
16.3 16.3 15.2 15.3 13.4 16.3 16.3 15.8 15.8 14.4 16.3 16.3 16.3 16.3 15.5
KW
1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6
95
T.C.
19.5 21.4 21.2 23.3 25.0 21.6 22.8 22.6 24.8 26.8 23.7 24.2 23.9 26.3 28.5
S.C.
16.3 16.3 14.7 15.0 12.9 16.3 16.3 15.5 15.6 14.0 16.3 16.3 16.3 16.3 15.1
KW
1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8
105
T.C.
18.4 20.1 19.9 22.0 23.7 20.4 21.4 21.1 23.4 25.2 22.4 22.6 22.4 24.7 26.8
S.C.
16.3 15.9 14.0 14.2 12.2 16.3 16.1 15.2 15.3 13.3 16.3 16.3 16.3 16.3 14.4
KW
2.2 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.2
115
T.C.
17.4 18.8 18.6 20.7 22.3 19.3 19.9 19.7 21.9 23.7 21.2 21.0 20.9 23.1 25.1
S.C.
16.3 15.4 13.4 13.5 11.6 16.3 15.9 14.8 14.9 12.6 16.3 16.3 16.3 16.3 13.6
KW
2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
125
T.C.
16.3 17.5 17.3 19.3 20.9 18.1 18.4 18.3 20.4 22.2 19.9 19.4 19.3 21.6 23.4
S.C.
16.3 15.0 12.7 12.8 10.9 16.3 15.7 14.5 14.6 11.9 16.3 16.3 16.3 16.3 12.9
KW
2.9 2.9 2.9 2.9 2.8 2.9 2.9 2.9 2.8 2.8 2.8 2.8 2.9 2.8 2.8
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handlers
Coils
T.C.
S.C.
KW
–
FC/MC/PC24
1.02
1.04
1.02
–
FC/MC/PC30
1.02
1.04
1.02
–
FC/MC/PC35
1.02
1.06
1.02
–
FC/MC/PC36
1.02
1.06
1.02
–
FC/MC/PC37
1.04
1.08
1.02
–
FC/MC/PC43
1.03
1.08
1.02
–
FC/MC/PC48
1.05
1.10
1.02
–
HC24
0.99
1.00
1.02
–
HC30
1.01
1.04
1.02
–
HC36
1.02
1.06
1.02
–
HC42
1.04
1.08
1.02
–
HD24
1.04
1.07
1.02
–
HD36
1.01
1.02
1.02
–
HD48
1.05
1.07
1.02
–
UC24
1.02
1.05
1.02
–
UC30
1.02
1.05
1.02
AHP24
–
1.01
1.04
1.01
AV24
–
1.02
1.05
0.93
AV36
–
1.05
1.09
0.93
AHX30
–
1.05
1.11
0.94
F6FP030
–
1.05
1.10
0.96
F4FP030
–
1.02
1.04
1.02
MA08B
FC/MC24B
1.02
1.04
1.02
MV12B
FC/MC24B
1.04
1.07
0.94
MA08B
FC/MC30B
1.02
1.04
1.02
MV12B
FC/MC30B
1.04
1.07
0.94
MA08B
FC/MC35B
1.02
1.06
1.02
MV12B
FC/MC35B
1.05
1.08
0.93
MV16C
FC/MC35C
1.05
1.08
0.93
MA08B
FC/MC36B
1.02
1.06
1.02
MV12B
FC/MC36B
1.05
1.08
0.93
MV16C
FC/MC36C
1.05
1.08
0.93
MA08B
FC/MC43B
1.03
1.08
1.02
MV12B
FC/MC43B
1.06
1.10
0.94
MV16C
FC/MC43C
1.06
1.10
0.93
MV16C
FC/MC48C
1.07
1.12
0.93
Air Handlers
Coils
T.C.
S.C.
KW