Unitary Products Group

PRODUCT NOMENCLATURE

  

25T Sunline™ 2000 Model Number Nomenclature

D M 300 N 24 A 7 A AA 1

Product Category

D = Air Cond., Single Package

Product Generation

1 = First Generation

Product Identifier

M = R-22 Standard Efficiency

Installation Options

Additional Options

A = No Options Installed

(See Next Page)

Voltage

B = Option 1
C = Option 2

7 = 380/415-3-50

D = Options 1 & 2

Nominal Cooling
Capacity - MBH

E = Option 3

300 = 25 Ton

F = Options 4
G = Options 1 & 3
H = Options 1 & 4
J = Options 1, 2 & 3
K = Options 1, 2, & 4

A= Std Motor/Drive

L = Options 1,3 & 4

B = Std Mtr/Drive/Single Input Econo

M = Options 1, 2, 3, & 4

C = Std Mtr/Drive/Single Input Econo/Power Exhaust*

N = Options 2 & 3

D = Std Mtr/Drive/Motorized Damper

P = Options 2 & 4

Heat Type & Nominal Heat Capacity

F = Std Mtr/Drive/4" Filters

Q = Options 2, 3, & 4

C00 = Cooling Only.  No field installed electric heat

G = Std Mtr/Drive/4" Filters/Single Input Econ

R = Options 3 & 4

Gas Heat Options

H = Std Mtr/Drive/4" Filters/Single Input Econ/Power Exhaust*

S = Option 5

N24 = 240 MBH Output Aluminized Steel

L = Std Mtr/Drive/BAS Ready Econ (No BAS Controller) w/2" Pleated Filters

T = Options 1 & 5

M = Std Mtr/Drive/BAS Ready Econ (No BAS Controller)/Power Exhaust w/2" Pleated Filters*

U = Options 1, 3, & 5
V = Options 1, 4, & 5
W = Options 1, 3, 4, & 5

Electric Heat Options

X = Options 3 & 5

E18 = 18 KW

Y = Options 4 & 5

E36 = 36 KW

Z = Options 3, 4, & 5

E54 = 54 KW

Options

E72 = 72 KW 

1 = Disconnect
2 = Non-Pwr'd Conv Oultet
3 = Smoke Detector S.A.
4 = Smoke Detector R.A.
5 = Pwr'd Conv. Outlet

Airflow

York Brand

N32= 320 MBH Output Aluminized Steel

Содержание Sunline 2000

Страница 1: ...verhead rigging Every unit is completely piped wired charged and tested at the fac tory to simplify the field installation and to provide years of depend able operation Powder paint cabinets provide a...

Страница 2: ...HOOD 20 6 CENTER OF GRAVITY 20 7 ROOF CURB DIMENSIONS ALL MODELS 21 8 ROOF CURB BENEFITS 21 9 UNIT CURB AND APPLICATIONS 21 10 TYPICAL APPLICATION 22 11 TYPICAL ROOF TOP INSTALLATION 22 LIST OF TABLES...

Страница 3: ...alarm on ignition failures compressor lockouts and repeated limit switch trips Nuisance Trip Protection and Strikes To prevent nuisance trouble calls the control board uses a three times you re out p...

Страница 4: ...phase monitor will shut the unit down in an out of phase condition DIRTY FILTER SWITCH This kit includes a differential pressure switch that energizes the fault light on the unit thermostat indicating...

Страница 5: ...y should be mounted on the return air duct ENTHALPY ACCESSORY CONTROL KIT This kit contains the required components to convert a single enthalpy economizer to dual enthalpy BURGLAR BARS Mount in the s...

Страница 6: ...ust N Options 2 3 D Std Mtr Drive Motorized Damper P Options 2 4 Heat Type Nominal Heat Capacity F Std Mtr Drive 4 Filters Q Options 2 3 4 C00 Cooling Only No field installed electric heat G Std Mtr D...

Страница 7: ...ontroller DFS APS Technicoat Cond Coil Phase Monitor CG CPC Controller DFS APS Technicoat Cond Coil Coil Guard CH CPC Controller DFS APS Technicoat Cond Coil Phase Monitor Coil Guard CJ CPC Controller...

Страница 8: ...oil Phase Monitor Coil Guard Hinged Filter Door Tooless Access Panels EN Johnson UNT Controller DFS APS Technicoat Evap Cond Coils Hinged Filter Door Tooless Access Panels EP Johnson UNT Controller DF...

Страница 9: ...Phase Monitor JC Johnson UNT Controller DFS APS Coil Guard JD Johnson UNT Controller DFS APS Phase Monitor Coil Guard JE Johnson UNT Controller DFS APS Technicoat Cond Coil JF Johnson UNT Controller D...

Страница 10: ...coat Evap Coil Phase Monitor Hinged Filter Door Tooless Access Panels PL Novar ETC 3 Controller DFS APS Technicoat Evap Coil Coil Guard Hinged Filter Door Tooless Access Panels PM Novar ETC 3 Controll...

Страница 11: ...Technicoat Evaporator Coil Phase Monitor Hinged Filter Door Tooless Access Panels UL Technicoat Evaporator Coil Coil Guard Hinged Filter Door Tooless Access Panels UM Technicoat Evaporator Coil Dirty...

Страница 12: ...27 3 67 49 32 88 32 0 62 45 28 20 100 24 0 90 71 53 35 94 26 4 89 69 51 34 83 31 2 83 64 47 30 17 94 23 5 94 94 74 55 90 25 9 90 89 72 53 79 30 5 79 77 66 47 14 94 23 5 94 94 88 76 89 25 8 89 89 83 74...

Страница 13: ...5 268 265 247 230 9000 73 362 24 6 219 164 110 341 27 1 214 158 105 295 31 8 200 144 93 68 334 23 9 287 228 171 116 315 26 2 282 222 166 111 275 30 7 261 206 151 96 63 311 23 2 311 296 236 178 295 25...

Страница 14: ...1040 3 0 443 6 6 5 4 347 8 1 6 7 228 9 7 8 0 1070 2 0 489 6 9 5 7 396 8 5 7 0 280 10 2 8 3 1100 1 0 536 7 3 6 0 445 8 9 7 3 332 10 6 8 7 1130 0 0 583 7 6 6 2 495 9 3 7 6 385 11 0 9 0 DM300 UNIT DOWNF...

Страница 15: ...ted in the respective blower performance table except for Horizontal Duct Connections Add these values due to less airflow resistance TABLE 7 BLOWER MOTOR AND DRIVE DATA MODEL SIZE BLOWER RANGE RPM MO...

Страница 16: ...or 102mm optional QUANTITY PER UNIT 406 x 508 x 51 mm 2 16 x 20 x 2 in QUANTITY PER UNIT 406 x 635 x 51 mm 4 16 x 25 x 2 in QUANTITY PER UNIT 457 x 610 x 51 mm 3 14 x 20 x 2 in TOTAL FACE AREA m2 Ft 2...

Страница 17: ...26 9 2 37 4 76 0 90 E054 40 4 2 56 2 94 0 100 E072 53 8 2 74 9 98 6 110 1 Electric Heat CORRECTION FACTORS 2 Dual element time delay fuse or HACR breaker NOMINAL VOLTAGE VOLTAGE KW CAP MULTIPLIER 415...

Страница 18: ...AL BLOCK TERMINALS ON A LIMITED NUMBER OF THERMOSTATS 3 1 2 4 3 1 2 4 Second stage heating not required on single stage heating units Second stage cooling not required on single stage cooling units Ju...

Страница 19: ...be installed outdoors Overhanging structures or shrubs should not obstruct condenser air discharge outlet Note Cool Only Models Units and ductwork are approved for zero clearance to combustible materi...

Страница 20: ...are closed with sheet metal covers except when the unit includes a power exhaust option The cov ering consists of a black paper composition 3 Replace the side supply and return air compartment panels...

Страница 21: ...ONS ALL MODELS Supply and Return air including duct support rails as shown are typical for Downflow duct applications For location of Sideflow duct applica tions on back of unit refer to Unit Dimensio...

Страница 22: ...036 21060 004 A 1102 22 Unitary Products Group FIGURE 10 TYPICAL APPLICATION FIGURE 11 TYPICAL ROOF TOP INSTALLATION GAS ELECTRIC UNIT SHOWN...

Страница 23: ...036 21060 004 A 1102 Unitary Products Group 23...

Страница 24: ...o change without notice Printed in U S A 036 21060 004 A 1102 Copyright by Unitary Products Group 2002 All rights reserved Supersedes 036 21060 003 A 0802 Unitary 5005 Norman Products York OK Group Dr...

Отзывы: