COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils

*

UNIT MODEL

FURNACE**

COIL

MODEL

COOLING

CFM RANGE

(MIN.-MAX.)

W

RATED 

CFM

NET MBH

SEER

W/O TXV

SEER

+ TXV

1

EER

TOTAL

SENS.

H4DH018S06

575
725

14,17

G1FA024S14,17

650

18.2

13.7

12.20

-

10.60

14

G1FA030S14

650

18.8

14.1

12.50

-

10.70

14

G1FA036S14

650

19.2

14.4

12.60

-

10.80

17,21

G1FA036S17,21

650

19.4

14.6

12.60

-

10.80

-

G1HD024

650

18.6

14.0

12.00

-

10.60

17

G1NA030S17H

650

18.8

14.1

12.70

-

12.10

14,17

G1UA024S14,17

650

18.2

13.7

12.20

-

10.60

14

G1UA030S14

650

18.8

14.1

12.50

-

10.70

14

G1UA036S14

650

19.2

14.4

12.60

-

10.80

17,21

G1UA036S17,21

650

19.4

14.6

12.60

-

10.80

14,17

G2FD024(S,H)14,17

650

18.6

14.0

12.50

-

10.80

17

G2FD030(S,H)17

650

19.0

14.3

12.50

-

10.80

14

G2FD035(S,H)14

650

19.2

14.4

12.60

-

10.90

H4DH024S06

750
950

14,17

G1FA024S14,17

850

23.4

17.6

12.00

-

10.80

14

G1FA030S14

850

23.4

17.6

12.10

-

10.90

14

G1FA036S14

850

24.0

18.0

12.00

-

10.80

17,21

G1FA036S17,21

850

24.0

18.0

12.00

-

10.90

-

G1HD024

850

23.4

17.6

12.00

-

10.70

-

G1HD036

850

24.0

18.0

12.10

-

10.90

17

G1NA030S17H

850

24.0

18.0

12.40

-

11.10

14,17

G1UA024S14,17

850

23.4

17.6

12.00

-

10.80

14

G1UA030S14

850

23.4

17.6

12.10

-

10.90

14

G1UA036S14

850

24.0

18.0

12.00

-

10.80

17,21

G1UA036S17,21

850

24.0

18.0

12.00

-

10.90

14,17

G2FD024(S,H)14,17

850

23.4

17.6

12.10

-

10.90

17

G2FD030(S,H)17

850

23.4

17.6

12.00

-

10.90

14

G2FD035(S,H)14

850

23.4

17.6

12.00

-

10.80

17

G2FD036(S,H)17

850

24.0

18.0

-

12.10

10.90

H4DH030S06

900

1150

14

G1FA030S14

1030

29.0

21.8

-

12.00

10.30

17,21

G1FA036S17,21

1030

30.4

22.8

12.10

-

10.40

17

G1FA048S17

1030

31.4

23.6

12.60

-

10.70

21,24

G1FA048S21

1030

31.4

23.6

12.60

-

10.70

-

G1HD036

1030

30.0

22.5

12.20

-

10.50

17

G1NA030S17K

1030

29.4

22.1

12.00

-

10.50

14

G1UA030S14

1030

29.0

21.8

-

12.00

10.30

17,21

G1UA036S17,21

1030

30.4

22.8

12.10

-

10.40

17

G1UA048S17

1030

31.4

23.6

12.60

-

10.70

21,24

G1UA048S21

1030

31.4

23.6

12.60

-

10.70

17

G2FD030(S,H)17

1030

29.4

22.1

-

12.40

10.50

14

G2FD035(S,H)14

1030

30.0

22.5

12.10

-

10.40

17

G2FD036(S,H)17

1030

30.0

22.5

12.40

-

10.60

21

G2FD036(S,H)21

1030

30.0

22.5

12.50

-

10.60

21,24

G2FD048(S,H)21,24

1030

31.0

23.3

12.60

-

10.60

H4DH036S06

1050
1350

17,21

G1FA036S17,21

1200

35.2

26.0

12.00*

-

11.00

17

G1FA048S17

1200

37.2

27.5

12.70

13.00*

11.45

21,24

G1FA048S21

1200

37.2

27.5

12.70

13.00*

11.50

-

G1HD036

1200

35.2

26.0

12.00

-

10.95

-

G1HD048

1200

37.8

28.0

12.50

-

11.15

17

G1NA036S17J

1200

35.4

26.2

12.20

-

11.15

21

G1NA048S21D

1200

37.0

27.4

-

12.90*

11.40

17,21

G1UA036S17,21

1200

35.2

26.0

12.00*

-

11.00

17

G1UA048S17

1200

37.2

27.5

12.70

13.00*

11.45

21,24

G1UA048S21

1200

37.2

27.5

12.70

13.00*

11.50

14

G2FD035(S,H)14

1200

35.2

26.0

12.00*

-

11.05

17

G2FD036(S,H)17

1200

35.8

26.5

12.15

-

11.20

21

G2FD036(S,H)21

1200

36.4

26.9

12.25

-

11.30

21

G2FD042(S,H)21

1200

36.2

26.8

12.30

-

11.20

17

G2FD046(S,H)17

1200

36.2

26.8

12.30

-

11.20

21,24

G2FD048(S,H)21,24

1200

37.8

28.0

12.80

13.00*

11.70

For Notes see Page 5.

Содержание STELLAR PLUS H4DH018 THRU 060

Страница 1: ...RESSOR The compressor is inter nally protected against high pressure and temperature This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the compressor if undesirable operating condi tions occur DURABLE FINISH Cabinet is made of powder painted steel over pre primered steel The pre treated galvanized steel provides a better paint ...

Страница 2: ... Load 0 5 0 5 0 9 1 2 1 2 1 2 1 4 Fan Diameter Inches 18 18 18 24 24 24 24 Fan Motor Rated HP 1 12 1 12 1 8 1 4 1 4 1 4 1 3 Nominal RPM 1100 1100 1075 850 850 850 1100 Nominal CFM 1500 1500 2050 3100 3100 3100 4100 Coil Face Area Sq Ft 14 1 14 1 14 1 20 20 24 24 Rows Deep 1 1 1 1 1 1 1 Fin Inches 20 20 20 18 18 20 20 Liquid Line OD 3 8 3 8 3 8 3 8 3 8 3 8 3 8 Vapor Line OD 5 8 3 4 3 4 3 4 7 8 7 8 ...

Страница 3: ...n the flow control device of each indoor coil 3 A TXV Kit must be used with these units to obtain system performance 701 702 703 indicates 1TV07 Series System Orifice Additional Charge Oz G2FD024 S H 14 17 61 57 6 63 2 G2FD030 S H 17 65 57 8 63 4 69 0 7013 0 G2FD035 S H 14 65 57 8 63 4 69 3 75 0 G2FD036 S H 17 21 75 63 8 69 3 75 10 G2FD042 S H 21 78 75 13 75 5 G2FD046 S H 17 78 71 6 75 13 75 5 87 ...

Страница 4: ...H048S06 N1VSC16 10 15 18 21 G2FD048 S H 21 1590 49 0 36 8 13 00 11 70 N1VSD20 10 15 18 30 24 G2FD060 S H 24 1600 50 5 37 9 13 10 11 90 H4DH060S06 N1VSD20 10 15 18 30 24 G2FD060 S H 24 1780 59 0 44 3 12 40 11 40 N1VSD20 10 15 18 30 24 G2FD061H24 1780 60 5 45 4 13 00 11 80 1 PH 12 SEER AC F2RP RC FP FC FV4 5 4 To meet R 4 2 insulation requirements substitute F2FP for F2RP and F2FC for F2RC models Al...

Страница 5: ...23 4 17 6 12 00 10 90 14 G2FD035 S H 14 850 23 4 17 6 12 00 10 80 17 G2FD036 S H 17 850 24 0 18 0 12 10 10 90 H4DH030S06 900 1150 14 G1FA030S14 1030 29 0 21 8 12 00 10 30 17 21 G1FA036S17 21 1030 30 4 22 8 12 10 10 40 17 G1FA048S17 1030 31 4 23 6 12 60 10 70 21 24 G1FA048S21 1030 31 4 23 6 12 60 10 70 G1HD036 1030 30 0 22 5 12 20 10 50 17 G1NA030S17K 1030 29 4 22 1 12 00 10 50 14 G1UA030S14 1030 2...

Страница 6: ... 48 0 36 0 12 20 11 00 21 24 G1FA048S21 1600 48 0 36 0 12 20 11 00 21 24 G1FA060S21 24 1600 49 5 37 1 12 50 13 00 11 35 G1HD048 1600 49 0 36 8 12 00 11 10 G1HD060 1600 49 5 37 1 12 20 11 35 21 G1NA048S21D 1600 47 0 35 3 12 00 10 85 17 G1UA048S17 1600 48 0 36 0 12 20 11 00 21 24 G1UA048S21 1600 48 0 36 0 12 20 11 00 21 24 G1UA060S21 24 1600 49 5 37 1 12 50 13 00 11 35 17 G2FD046 S H 17 1500 47 0 35...

Страница 7: ...FD024 S H 17 17 815 23 8 17 9 13 00 11 80 P1XUB12V G1FA024S17 17 820 24 0 18 0 13 00 11 95 P1XUB12V G1FA036S17 17 820 24 6 18 5 13 00 12 00 P1XUB12V G1UA024S17 17 820 24 0 18 0 13 00 11 95 P1XUB12V G1UA036S17 17 820 24 6 18 5 13 00 12 00 P1XUB12V G2FD024 S H 17 17 820 24 0 18 0 13 00 12 05 P1XUB12V G2FD030 S H 17 17 820 24 6 18 5 13 00 12 00 P1XUB12V G2FD036 S H 17 17 820 24 6 18 5 13 00 12 00 H4D...

Страница 8: ...5 P1XUC20V G1UA048S21 21 1200 38 0 28 1 13 90 12 60 P1XUC20V G2FD036 S H 21 21 1200 36 6 27 1 13 50 12 50 P1XUC20V G2FD042 S H 21 21 1200 37 0 27 4 13 50 12 45 P1XUC20V G2FD048 S H 21 21 1200 38 5 28 5 13 90 12 65 H4DH042S06 P1DUB16V G1FA048S17 17 1400 41 0 30 8 12 50 10 95 P1DUB16V G1HD048 1425 41 5 31 1 13 00 11 45 P1DUB16V G1UA048S17 17 1400 41 0 30 8 12 50 10 95 P1DUB16V G2FD046 S H 17 17 1400...

Страница 9: ... 25 11 55 P1XUC20V G2FD048 S H 21 21 1450 48 5 36 4 13 00 11 65 P1XUD20V G1FA060S24 24 1620 49 5 37 1 13 25 11 55 P1XUD20V G1UA060S24 24 1620 49 5 37 1 13 25 11 55 P1XUD20V G2FD048 S H 24 24 1620 48 5 36 4 12 50 11 25 P1XUD20V G2FD060 S H 24 24 1620 50 0 37 5 12 70 11 60 H4DH060S06 P1DUC20V G1FA060S21 21 1800 59 0 44 3 12 00 11 20 P1DUC20V G1HD060 1730 59 0 44 3 12 10 11 50 P1DUC20V G1UA060S21 21 ...

Страница 10: ...o the price book or consult factory Rated in accordance with ARI Standard 270 COOLING PERFORMANCE MODEL SUCT T P COMPR AIR TEMP ON CONDENSER MODEL SUCT T P COMPR AIR TEMP ON CONDENSER 75 F 95 F 115 F 75 F 95 F 115 F TEMP PSIG MBH KW MBH KW MBH KW TEMP PSIG MBH KW MBH KW MBH KW H4DH018S06 35 61 5 18 7 1 92 12 6 2 06 7 3 2 24 H4DH042S06 35 61 5 36 8 3 07 32 2 3 69 27 6 4 37 40 68 5 20 8 1 92 14 3 2 ...

Страница 11: ...8 OVERHEAD CLEARANCE 12 REAR AND SIDES NOTE All outdoor wiring must be weatherproof ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE NEC AND OR LOCAL CODES POWER WIRING 208 230 1 60 CONTACTOR TERMINALS COIL GND LUG C Y R G W Y R G W POWER WIRING CONTROL WIRING FACTORY WIRING 24 VOLT CONTROL WIRING MINIMUM 18 GA WIRE NEC CLASS 2 FURNACE OR AIR HANDLER TERMINAL BLOCK ROOM THERMOSTAT CONDENSIN...

Страница 12: ...9 12 3 11 3 K W 2 08 2 09 2 08 2 05 2 10 2 11 2 10 2 08 2 12 2 13 2 12 2 10 125 T C 12 8 11 5 10 2 9 5 12 8 11 5 10 6 9 6 13 0 11 6 10 9 9 8 S C 11 1 11 0 10 9 9 1 11 8 11 4 11 2 9 3 12 2 12 0 10 9 9 5 K W 2 26 2 26 2 24 2 20 2 28 2 28 2 26 2 23 2 31 2 30 2 28 2 25 NOTE ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH 1000 CFM Air Handler Coil T C S C KW N1AHB08 G2FD024 S H 17 1 02 1 02 1 00 N1...

Страница 13: ...9 8 18 2 16 4 21 6 19 9 18 3 16 7 S C 15 6 15 6 16 0 15 7 16 1 16 1 16 7 16 2 16 6 16 6 16 8 16 7 K W 2 77 2 75 2 71 2 67 2 78 2 77 2 73 2 71 2 80 2 78 2 75 2 73 NOTE ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH 1000 CFM Air Handler Coil T C S C KW N1AHB08 G2FD024 S H 17 1 00 1 00 0 99 N1AHB08 G2FD030 S H 17 1 00 1 00 0 99 N1VSB12 G2FD024 S H 17 1 04 1 04 0 93 N1VSB12 G2FD036 S H 17 1 05 1 ...

Страница 14: ...0 3 78 3 76 3 86 3 84 3 82 3 80 NOTE ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH 1000 CFM Air Handler Coil T C S C KW N1AHB12 G2FD030 S H 17 0 97 0 97 0 96 N1AHB12 G2FD036 S H 17 0 99 0 99 0 97 N1VSB12 G2FD036 S H 17 1 02 1 02 0 98 N1VSB12 G2FD046 S H 17 1 05 1 05 1 00 F2RC FC030 0 93 0 93 0 93 F2RP FP030 0 99 0 99 0 98 F2FP040 1 03 1 03 1 00 F2RP FP036 1 02 1 02 1 00 G1HD036 0 99 0 99 0 9...

Страница 15: ...1AHB12 G2FD046 S H 17 1 03 1 03 1 01 N1AHD14 G2FD048 S H 24 1 08 0 91 0 99 N1AHD14 G2FD060 S H 24 1 09 0 93 0 99 N1VSB12 G2FD036 S H 17 1 01 1 03 0 92 F2RP FP036 1 03 1 04 0 99 N1VSC16 G3FD048S21 1 08 1 09 0 95 F2RP FP042 1 03 1 05 0 99 F2FP045 1 08 1 09 0 97 F2FP048 1 05 1 06 0 97 F2RC FC036 1 01 1 03 1 00 G1FA048S24 1 06 1 06 1 01 G1HD036 1 00 1 00 1 00 G1HD048 1 07 1 07 1 06 G1NA036S17J 1 01 1 ...

Страница 16: ...9 6 29 7 29 3 30 7 30 6 30 9 30 7 K W 5 19 5 07 4 94 4 81 5 25 5 13 4 99 4 88 5 30 5 18 5 06 4 99 NOTE ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH 1000 CFM Air Handler Coil T C S C KW N1AHC16 G2FD042 S H 21 0 99 0 99 1 00 N1AHC16 G2FD048 S H 21 1 02 1 02 1 01 N1VSC16 G2FD048 S H 21 1 04 1 04 0 95 F2FP045 1 04 1 04 0 99 F2FP048 1 01 1 01 1 02 F2RP FP042 0 99 0 99 1 01 G1NA048S21D 0 99 0 99 ...

Страница 17: ... 31 2 30 9 31 3 31 8 32 8 32 1 33 4 33 2 34 5 35 0 34 4 35 1 K W 6 28 6 24 6 16 6 10 6 35 6 22 6 22 6 16 6 40 6 34 6 30 6 27 NOTE ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH 1000 CFM Air Handler Coil T C S C KW N1AHC16 G2FD048 S H 21 1 01 1 01 1 00 N1AHD20 G2FD060 S H 24 1 04 1 04 1 00 N1VSC16 G2FD048 S H 21 1 02 1 02 0 96 N1VSD20 G2FD060 S H 24 1 05 1 05 0 97 F2FP048 1 00 1 00 1 00 F2FP06...

Страница 18: ... 5 44 8 45 5 45 7 K W 6 03 5 98 5 93 5 88 6 10 6 05 6 00 5 95 6 15 6 10 6 05 6 00 115 T C 57 3 53 0 48 5 44 5 57 6 53 3 49 1 45 1 58 0 53 6 49 5 45 4 S C 40 2 40 4 40 8 41 1 41 7 41 9 42 9 43 0 43 6 43 6 44 5 44 5 K W 6 70 6 64 6 61 6 55 6 76 6 72 6 66 6 61 6 81 6 77 6 72 6 67 125 T C 54 3 50 3 45 9 42 0 54 6 50 5 46 6 42 8 55 0 50 7 47 0 43 0 S C 39 1 39 4 39 5 39 6 40 6 40 7 41 9 41 9 42 7 42 4 ...

Страница 19: ...ON UPFLOW HORIZONTAL AND DOWNFLOW Available with factory installed horizontal drain pan ADD ON COILS FOR FURNACE APPLICATIONS G1NA UNCASED UPFLOW G1FA FULL CASED UPFLOW AIR HANDLERS FOR NON FURNACE APPLICATIONS N1AH OR N1VS MODULAR BLOWER UPFLOW HORIZONTAL AND DOWNFLOW F2RC F2FC OR F2RC F2FP F2FV FAN COIL UNITS UPFLOW HORIZONTAL G2FD COIL ...

Страница 20: ...ge without notice Printed in U S A 036 21020 003 Rev C 0203 Copyright by York International Corp 2003 All rights reserved Supersedes 036 21020 003 Rev B 0702 Unitary 5005 Norman Product York OK Group Drive 73069 NOTES ...

Отзывы: