ELECTRICAL DATA
RSH/RSV ELECTRICAL DATA
Unit Size
SUPPLY
VOLTAGE
COMPRESSOR
BLOWER
MIN. CCT.
AMPACITY
MAX FUSE /
CCT. BKR. AMP
QTY
RLA
LRA
HP
FLA
007
208-230/1/60
1
@
3.4
22.0
0.10
0.8
5.05
15
009
208-230/1/60
1
@
4.6
28.0
0.10
0.8
6.55
15
012
208-230/1/60
1
@
5.6
29.0
0.13
1.0
8.00
15
265/1/60
1
@
4.6
20.0
0.13
0.9
6.65
15
018
208-230/1/60
1
@
6.9
48.0
0.17
1.4
10.03
15
265/1/60
1
@
6.1
44.0
0.17
0.8
8.43
15
024
208-230/1/60
1
@
8.2
48.0
0.25
1.5
11.75
15
265/1/60
1
@
7.0
44.0
0.25
1.3
10.05
15
208-230/3/60
1
@
6.1
58.0
0.25
1.3
8.93
15
030
208-230/1/60
1
@
10.1
60.0
0.33
2.6
15.23
25
265/1/60
1
@
8.7
58.0
0.33
1.9
12.78
20
208-230/3/60
1
@
7.2
58.0
0.33
2.6
11.60
15
036
208-230/1/60
1
@
13.5
83.0
0.50
3.2
20.08
30
265/1/60
1
@
11.6
79.0
0.50
2.2
16.70
25
208-230/3/60
1
@
8.7
78.0
0.50
3.2
14.08
20
460/3/60
1
@
4.3
40.0
0.50
2.5
7.88
15
042
208-230/1/60
1
@
19.9
109.0
0.50
3.2
28.08
45
208-230/3/60
1
@
13.6
81.0
0.50
3.2
20.20
30
460/3/60
1
@
6.1
41.0
0.50
2.5
10.13
15
575/3/60
1
@
4.2
33.0
0.50
1.8
7.05
15
048
208-230/1/60
1
@
23.1
144.0
0.75
4.9
33.78
50
208-230/3/60
1
@
16.0
91.0
0.75
4.9
24.90
40
460/3/60
1
@
7.1
46.0
0.75
2.2
11.08
15
575/3/60
1
@
5.6
37.0
0.75
1.8
8.80
15
060
208-230/1/60
1
@
26.3
134.0
1.00
5.1
37.98
60
208-230/3/60
1
@
15.6
110.0
1.00
5.1
24.60
40
460/3/60
1
@
7.8
52.0
1.00
3.2
12.95
20
575/3/60
1
@
5.8
38.9
1.00
2.6
9.85
15
070
208-230/3/60
1
@
19.0
123.0
1.00
5.1
28.85
45
460/3/60
1
@
9.7
62.0
1.00
3.2
15.33
25
575/3/60
1
@
7.4
50.0
1.00
2.6
11.85
15