background image

ENGLISH

21

EN

TECHNICAL SPECIFICATIONS

Models

Indoor

Unit

RAEC-RAKC

RAEC07 RAKC07 RAEC09 RAKC09 RAEC12 RAKC12 RAEC18 RAKC18 RAEC24 RAKC24 RAEC28 RAKC28

Outdoor

Unit

RADC-RAJC

RADC07 RAJC07 RADC09 RAJC09 RADC12 RAJC12 RADC18 RAJC18 RADC24 RAJC24 RADC28 RAJC28

Power Supply

V/Ph/Hz

220-240/1/50

Ph

1

1

1

1

1

1

Power Consumption

kW

0.64

0.64

0.82

0.82

1.12

1.12

1.72

1.72

2.53

2.53

2.60

2.60/2.68

Running Current

A

2.8

2.8

3.6

3.6

5.0

5.0

7.8

7.8

11.2

11.2

12.2

12.2/12.3

Refrigerant Type

R410A

Refrigerant Charge

gr

800

820

900

920

1050

1080

1690

1740

1900

1950

1950

2000

Noise level

Indoor

dB(A)

35/32/30 35/32/30 37/34/31 37/34/31 40/37/34 40/37/34 42/39/37 42/39/37 45/42/39 45/42/39 47/44/41 47/44/41

Outdoor

49

49

50

50

50

50

52

52

55

55

57

57

Indoor Unit

Power Supply

V/Ph/Hz

220-240/1/50

Ph

1

1

1

1

1

1

Fan

Air 

fl

 ow

m

3

/h

450

450

500

500

580

600

850

850

1080

1080

1150

1150

Input Power

W

36.5

36.5

39.5

39.5

44

44

53

53

65

65

70

70

Running Current

A

0.17

0.17

0.17

0.17

0.2

0.2

0.26

0.26

0.37

0.37

0.32

0.32

Dimension

Height

mm

250

250

250

250

265

265

292

292

330

330

330

330

Width

mm

710

710

710

710

790

790

920

920

1080

1080

1080

1080

Depth

mm

190

190

190

190

193

193

225

225

225

225

225

225

Weight

kg

8

8

8

8

9

9

13

13

17

17

17

17

System Operation Control

Wireless Control with LCD Display

Outdoor Unit

Power Supply

V/Ph/Hz

220-240/1/50

Ph

1

1

1

1

1

1

Compressor

Qty

1

1

1

1

1

1

1

1

1

1

1

1

Compressor Type

Rotary

Dimension

Height

mm

535

535

540

540

540

540

695

695

695

695

695

695

Width

mm

700

700

780

780

780

780

845

845

845

845

845

845

Depth

mm

235

235

250

250

250

250

335

335

335

335

335

335

Weight

kg

31

32

36

37

37

38

52

52

59

60

60

61

Piping

Type

Flare + Nuts

Pipe 
Size

Suction

inch

3/8

3/8

3/8

3/8

1/2

1/2

1/2

1/2

5/8

5/8

5/8

5/8

Liquid

inch

1/4

1/4

1/4

1/4

1/4

1/4

1/4

1/4

3/8

3/8

3/8

3/8

Technical Speci

fi

 cations : Everest RACC-RAHC “R410A” -50Hz

Remark : 

The above design and speci

fi

 cations are subject to change without prior notice for product improvement.

J277-EN.indd   21

J277-EN.indd   21

26.12.2005   15:15:34 Uhr

26.12.2005   15:15:34 Uhr

Содержание RLCA-RLHA 07-30

Страница 1: ...ELS RLCA RLHA 07 30 RLCB RLHB 07 28 RACC RAHC 07 28 MINISPLIT HIGH WALL AIR CONDITIONER EN 035M80147 000 The units comply with one or more of the following marks see unit for details J277 EN 1 J277 EN...

Страница 2: ...tent reli ability in product service and support through superior quality service culture and distinctive technology R22 R407C 50Hz 60Hz 50Hz Set RLCAxxFSAAAR RLCAxxFSAADR RLCBxxFSAAAR RLHAxxFSAAAR RL...

Страница 3: ...ous and can cause injury Installation and maintenance of this air conditioning system should only be carried out by trained and qualified personnel After unpacking please check the unit carefully for...

Страница 4: ...ERATURE indicator Displays the temperature settings when the air conditioner is operational 4 OPERATION indicator This indicator flashes after power is on and illuminates when the unit is in operation...

Страница 5: ...conditioner will automatically increase cooling or decrease heating 1 C per hour The set temperature will be steady 2 hours later The fan speed will be automatically controlled DRYING OPERATION The d...

Страница 6: ...ord and the main breaker capacity are sufficient and the installation area is sufficient and complies with the requirements Check that the power supply available agrees with name plate voltage Electri...

Страница 7: ...48 115 90 266 272 298 285 290 530 110 62 590 750 RLDA RLJA 07 09 RLDB RLJB 07 09 RADC RAJC 07 RLDA RLJA 12 18 RLDB RLJB 12 RADC RAJC 09 12 RLDA RLJA 24 30 RLDB RLJB 24 28 RADC RAJC 18 28 RLDB RLJB 18...

Страница 8: ...tres or more from the floor A B and C directions should be free from obstructions NOTES This illustration is for explanation purposes only Copper lines must be insulated independently C B A 1 2 3 5 4...

Страница 9: ...l Carefully arrange pipes so that pipes do not stick out of the rear plate of the indoor unit A B C D E F MODEL 24 30 Right Right Right Right Left Rear Bottom Drain hose Drain hose is flexible and can...

Страница 10: ...smitted to the building struc ture Connect the pipe correctly Do not apply the excessive torque Use an appropriate bending tool to form curves and avoid over tightening the refrigerant tubes To preven...

Страница 11: ...rs Liquid Cooling GAS Cooling suction Low pressure High pressure Manifold Gas valve Liquid valve Pressure tap Outdoor unit Indoor unit Gas line Liquid line R22 R407C R410A Outdoor heat pump unit insta...

Страница 12: ...isconnecting device must have a contact separation of at least 3 mm Models 07 18 Cooling only Power supply Indoor L N 1 2 N 1 2 N Outdoor CAUTIONS Models 07 18 Cooling and Heating L N 1 2 N 3 4 1 2 N...

Страница 13: ...1 2 N S L N Terminal block of indoor unit Cooling only type cooling heating type Terminal block of indoor unit Cord clamp To outdoor unit To outdoor unit Terminal block of outdoor unit Wire holding b...

Страница 14: ...50Hz 32A 220 230V 60Hz NOTE b Unit has been running at high temperature protection mode for 90 minute High temperature protection mode when coil temperature of indoor unit reaches 55 C outdoor unit w...

Страница 15: ...the unit 2 Stop the air conditioner and disconnect power Remove the batteries from the remote controller 3 The outdoor unit requires periodic maintenance and cleaning Do not attempt to do this yourse...

Страница 16: ...condition when the air conditioner has not been used for a long time or during first use of the unit 5 A peculiar smell comes out from the indoor unit This is caused by the indoor unit giving off sme...

Страница 17: ...s tem 1 Remove charge repair evacuate and recharge 2 Insulate them separately 3 Wait while unit has enough time to cool the room D The compressor runs con tinuously 1 Thermostat adjustment too low in...

Страница 18: ...Hz 220 240 1 50 Ph 1 1 1 1 1 1 Fan Air flow m3 h 400 400 450 450 580 580 800 800 1080 1080 1150 1150 Input Power W 39 5 39 5 39 5 39 5 38 5 38 5 53 53 65 65 70 70 Running Current A 0 17 0 17 0 17 0 1...

Страница 19: ...0 14 0 14 0 14 0 14 0 24 0 24 0 68 0 68 0 34 0 34 Dimension Height mm 250 250 250 250 265 265 292 292 330 330 330 330 Width mm 710 710 710 710 790 790 920 920 1080 1080 1080 1080 Depth mm 190 190 190...

Страница 20: ...Running Current A 0 17 0 17 0 17 0 17 0 2 0 2 0 26 0 26 0 37 0 37 0 32 0 32 Dimension Height mm 250 250 250 250 265 265 292 292 330 330 330 330 Width mm 710 710 710 710 790 790 920 920 1080 1080 1080...

Страница 21: ...65 65 70 70 Running Current A 0 17 0 17 0 17 0 17 0 2 0 2 0 26 0 26 0 37 0 37 0 32 0 32 Dimension Height mm 250 250 250 250 265 265 292 292 330 330 330 330 Width mm 710 710 710 710 790 790 920 920 108...

Страница 22: ...ces should refrigerant be vented to atmosphere Where appropriate drain the refrigerant oil from each system into a suitable container and dispose of according to local laws and regulations governing d...

Отзывы: