YORK INTERNATIONAL
17
FORM 160.52-N1
If the motor has been in storage for 6 months prior
to commissioning, lubricate the motor bearings per
the following instructions prior to start-up.
If the motor is inactive for 30 days, the motor shaft
is to be rotated 15 revolutions in order to distribute
the grease within the bearing.
Some bearing squeal may be noted at start-up. This
is often due to the bearing cage, as it vibrates against
the moving bearing elements. This noise should sub-
side after a few days of operation. Intermittent bear-
ing squeal is not cause for alarm.
Use only Texaco Premium RB (Code 1939)
grease
to lubricate the motor bearings, as indicated
in Reliance literature for these motors. The grease
is readily available throughout most of the world, from
Texaco distributors and in Africa, Australia, and
the Pacific Rim countries from Caltex distributors.
Other types of grease may be chemically and me-
chanically incompatible with this Texaco Premium
RB grease, and
are not to be used.
Add 1.5 cubic inches of
Texaco Premium RBgrease
every 1800 hours of operation of the motor. Do not
expect to see grease exiting the grease relief port
during these re-lubrications.
Additional information on motor lubrication and other
service issues can be found in the Reliance Electric
A-C Motors Instruction Manual.
FOUNDATION
A level floor, mounting pad or foundation must be pro-
vided by others, capable of supporting the operating
weight of the unit.
CLEARANCE
Clearances should be adhered to as follows:
Rear and above unit – 2 ft.
Front of unit – 3 ft.
Tube Removal – 14 ft. (either end)