York MAL-MAM 18 Скачать руководство пользователя страница 4

4

AIR BLOWER

YORK Technical Guide Code 035T76009-000

4 - DIMENSIONS

LEFT SIDE VIEW

FRONT VIEW

OUTDOOR UNIT

Outdoor unit dimensions are shown in the Technical Specifications table, page 3.

N

B

D

F

A

D

E

F

I

G

H

MOL/MOM 45-55

MOL/MOM 25-35

MOL/MOM 18

28

28

M

C

MAL 18

MAL 25

MAL 35

MAL 45

MAL 55

A

845

897

962

1,102

1,400

B

532

567

628

640

640

C

305

305

325

350

350

D

240

240

268

280

280

E

160

160

160

220

220

F

102.5

128.5

133

161

309

G

110

112

115

230

230

H

125

155

145

78

78

I

75

43

65

42

42

J

660

605

744

854

1,152

K

110

192

140

158

158

L

75

100

78

90

90

M

249

249

269

294

294

N

462.5

497

558

570

570

Dimension

Model

LIQUID PIPE

SUCTION PIPE

J

K

L

28

28

M

H

W

D

W

D

H

H

W

D

RIGHT SIDE VIEW

REAR VIEW (FILTER)

02_MAL-MAM.p65 

20/4/02, 09:42

4

Содержание MAL-MAM 18

Страница 1: ...MINISPLIT AIR BLOWER 035T76009 000 TECHNICAL GUIDE MODELS MAL MAM 18 55 01_MAL MAMCover p65 19 4 02 11 28 1...

Страница 2: ...interconnection cord used must not be lighter than Polychloroprene sheated cord 245 IEC 57 or H05RN F Disconnecting device must have a contact separation of at least 3 mm GENERAL PRECAUTIONS Check th...

Страница 3: ...76 8 89 13 8 7 97 10 12 1 R 407C 1 170 1 380 1 700 2 500 3 000 102 204 330 330 330 305 305 325 350 350 845 897 962 1 102 1 400 532 567 628 640 640 32 51 53 66 88 Wired or Wireless Control with LCD Dis...

Страница 4: ...MAL 35 MAL 45 MAL 55 A 845 897 962 1 102 1 400 B 532 567 628 640 640 C 305 305 325 350 350 D 240 240 268 280 280 E 160 160 160 220 220 F 102 5 128 5 133 161 309 G 110 112 115 230 230 H 125 155 145 78...

Страница 5: ...inimum of clearance is necessary around the units to ensure proper air circulation and easy access for maintenance CLEARANCE REQUIRED FOR INDOOR UNITS C B D A E Unit A B C D E 18 400 200 100 250 600 2...

Страница 6: ...0 mm in height must also be provided If possible install a U bend fitted with an inspection cap Where the condensate lines from several units are joined together each individual outlet must be fitted...

Страница 7: ...pump and down to 5 pa 3 When pump down is finished wait 15 minutes to detect potential circuit leakage Open service valves on the outdoor unit If piping length exceeds 5 meters add 10 g of refrigerant...

Страница 8: ...L W O FILTER 230 1 50 Avialable Ext Static Pa Airflow CMH Hi 180 160 140 120 100 80 60 40 20 0 300 00 500 00 700 00 900 00 1100 00 1300 00 1500 00 Me Lo Avialable Ext Static Pa Airflow CMH FAN PERFORM...

Страница 9: ...is used to protect against any damage to the unit caused by fluctuation of voltage If voltage is lower than the lower limit for approximately 10 seconds or longer compressor operation will be tempora...

Страница 10: ...st be pressed again to reset the timer function To cancel either the Start or Stop Timer setting press the CANCEL button To check the time that has been entered either for starting or stopping the uni...

Страница 11: ...al Operation Normal Operation Normal Operation Normal Operation Normal Operation Normal Operation Protection Protection Protection Protection Protection Reset Call Service Technician Reset Call Servic...

Страница 12: ...80 415V 3Ph 50Hz 480V 3Ph 60Hz Power supply 380 415V 3Ph 50Hz 480V 3Ph 60Hz N 1 2 3 N 1 2 3 L1 L2 L3 N 1 2 L N 1 2 Indoor unit Indoor unit Outdoor unit Indoor unit Outdoor unit Indoor unit Unit size P...

Страница 13: ...more often if necessary Each season before start up Each season before start up MAINTENANCE OPERATIONS 1 Clean with a vacuum cleaner or tap gently then wash in warm water 40 C with a mild detergent 2...

Страница 14: ...ection factor C2 Capacity correction factor for temperature Indoor unit 10 0 98 5 1 00 R C Standard rating conditions Indoor 27 C DB 19 5 C WB Outdoor 35 C DB 24 C WB Operating temperature limits Cool...

Страница 15: ...YORK Technical Guide Code 035T76009 000 AIR BLOWER 15 03_MAL MAM p65 20 4 02 09 43 15...

Страница 16: ...to a suitable container using a refrigerant reclaim or recovery unit This refrigerant may then be re used if appropriate or returned to the manufacturer for disposal Under No circumstances should refr...

Отзывы: