TABLE 12: ELECTRICAL DATA - DK-12 W/O PWRD CONVENIENCE OUTLET
TABLE 13: ELECTRICAL DATA - DK-12 W/PWRD CONVENIENCE OUTLET
RLA
LRA
FLA
3
5
3
5
3
5
3
5
3
5
ea.
ea.
ea.
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
None
--
--
61.9
67.1
67.4 72.6
80
80
80
90
2TP04521825
13.5
37.5
61.9
67.1
67.4 73.8
80
80
80
90
2TP04522425
18
50.0
76.1
82.6
83.0 89.5
80
90
90
90
2TP04523625
25.5
70.8
102.1 108.6 109.0 115.5 110 110
110
125
2TP04525425 40.6
112.7 154.5 161.0 161.4 167.9 175 175
175
175
None
--
--
61.9
67.1
67.4 72.6
80
80
80
90
2TP04521825
18
43.3
67.8
74.3
74.6 81.1
80
80
80
90
2TP04522425
24
57.7
85.8
92.3
92.7 99.2
90 100
100
100
2TP04523625
34
81.8
115.9 122.4 122.7 129.2 125 125
125
150
2TP04525425 54
129.9 143.5 150.0 150.4 156.9 175 175
175
175
None
--
--
27.4 30.2 29.6 32.4 35 35
35
40
2TP04521846
18
22.6
33.7 37.2 36.4 39.9 35 40
40
40
2TP04522446
24
30.1
42.7 46.2 45.5 49 45 50
50
50
2TP04523646
34
42.7
57.7 61.2 60.5 64 60 70
70
70
2TP04525446
54
67.8
71.6 75.1 74.3 77.8 80 90
80
90
None
--
--
22.5 24.4 24.3 26.2 25 30
30
30
2TP04521858
18
18.1
26.8 29.2 29 31.4 30 30
30
35
2TP04522458
24
24.1
34
36.4 36.2 38.6 35 40
40
40
2TP04523658
34
34.1
46
48.4 48.3 50.6 50 50
50
60
2TP04525458
54
54.2
57.1 59.5 59.3 61.7 70 70
70
70
*
Voltage
Compressors
OD Fan
Motors
Supply
Blower
Motor FLA
Pwr
Exh
Motor
Pwr
Conv
Outlet
Electric Heater
Model No.
Actual
KW
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse Size
w/Power
Exhaust
(Amps)
FLA
FLA
208
20.0
146.0
1.5
10.9 16.1
5.5
0.0
230
20.0
146.0
1.5
10.9 16.1
5.5
0.0
460
8.4
73.0
0.8
5.3
8.1
2.2
0.0
575
7.1
60.0
0.6
4.1
6.0
1.8
0.0
Maximum HACR breaker of the same AMP size is applicable.
RLA
LRA
FLA
3
5
3
5
3
5
3
5
3
5
ea.
ea.
ea.
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
None
--
--
71.9
77.1
77.4 82.6
90
90
90
100
2TP04521825
13.5
37.5
73.0
79.5
79.8 86.3
90
90
90
100
2TP04522425
18
50.0
88.6
95.1
95.5 102.0 90 100
100
110
2TP04523625
25.5
70.8
114.6 121.1 121.5 128.0 125 125
125
150
2TP04525425 40.6
112.7 167.0 173.5 173.9 180.4 175 175
175
200
None
--
--
71.9
77.1
77.4 82.6
90
90
90
100
2TP04521825
18
43.3
80.3
86.8
87.1 93.6
90
90
90
100
2TP04522425
24
57.7
98.3
104.8 105.2 111.7 100 110
110
125
2TP04523625
34
81.8
128.4 134.9 135.2 141.7 150 150
150
150
2TP04525425 54
129.9 156.0 162.5 162.9 169.4 175 175
175
175
None
--
--
32.4 35.2 34.6 37.4 40 40
40
45
2TP04521846
18
22.6
39.9 43.4 42.7 46.2 40 45
45
50
2TP04522446
24
30.1
49
52.5 51.7 55.2 50 60
60
60
2TP04523646
34
42.7
64
67.5 66.7 70.2 70 70
70
80
2TP04525446
54
67.8
77.8 81.3 80.6 84.1 90 90
90
90
None
--
--
26.5 28.4 28.3 30.2 30 35
35
35
2TP04521858
18
18.1
31.8 34.2 34 36.4 35 35
35
40
2TP04522458
24
24.1
39
41.4 41.2 43.6 40 45
45
45
2TP04523658
34
34.1
51
53.4 53.3 55.6 60 60
60
60
2TP04525458
54
54.2
62.1 64.5 64.3 66.7 70 70
70
70
*
Voltage
Compressors
OD Fan
Motors
Supply
Blower
Motor FLA
Pwr
Exh
Motor
Pwr
Conv
Outlet
Electric Heater
Model No.
Actual
KW
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse Size
w/Power
Exhaust
(Amps)
FLA
FLA
208
20.0
146.0
1.5
10.9 16.1
5.5
10.0
230
20.0
146.0
1.5
10.9 16.1
5.5
10.0
5.0
460
8.4
73.0
0.8
0.6
5.3
8.1
2.2
Maximum HACR breaker of the same AMP size is applicable.
4.1
6.0
1.8
4.0
575
7.1
60.0
Содержание MagnaDRY DK-07 Series
Страница 53: ...335224 BIM B 1208 Johnson Controls Unitary Products 53 FIGURE 33 DK 07 AND DK 10 REHEAT CONTROLS...
Страница 54: ...335224 BIM B 1208 54 Johnson Controls Unitary Products FIGURE 34 DK 12 REHEAT CONTROLS...
Страница 74: ...335224 BIM B 1208 74 Johnson Controls Unitary Products...
Страница 75: ...335224 BIM B 1208 Johnson Controls Unitary Products 75...