![York HVQ 515 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/york/hvq-515/hvq-515_installation-and-user-manual_3542913007.webp)
Page 7 (of 7)
Fig..7
S
3
L
3
T
c) Now we put the front additional jaw on forehead (2) with guiding rods (6) and everything we insert to
base (11) , which is already installed on underneath od working desk . We put the clip (8) and we secure
by safety ring (9) and and we fast the jaw of vise on total touch-down . Than we have to seat the top
edge of front jaw with top edge of the rear additional jaws or with edge of collar desk . In case , that
everything is O.K. , we can fast screws
S
2
on base (1)and we fast the forehead (2) to front additional jaw
by screws
S
3
after picture (7) .
d) Finally, check the operation of the vice’s quick-automatic system. By turning the spindle (3) counter
clockwise (CCW) by 1.5 to 2 revolutions the nut (4) and spindle (3) disengage. Then the spindle can be
moved axially (direction of axis) to the required distance. After subsequently turning the spindle (3)
clockwise (CW) by 1.5 to 2 revolutions the nut (4) and spindle (3) engage and further turning tightens
the screw the standard way.
- Vice disassembly is done by reversing the steps described in this User Manual.
Fixing of
additional front jaw
L
3
mm/"
ks
HVQ 515
4-6
(0,16"-0,24")
T
2
3-5
(0,12"-0,2")
HVQ 516
6-8
(0,24"-0,32")
T
3
5-6
(0,2"-0,24")
S
3
mm/"