York HFG02 Скачать руководство пользователя страница 25

 

HFG02 Operation Manual 

 

York EMC Services 

Page 25 of 25    Doc. No. Y0321/DOC/024 Rev. 3 

General Information 

 

Ordering Information 

Standard Order Kits are listed for each product 
in the YES Products Brochure. Please refer to 
the appropriate part number when requesting a 
quote for a test instrument or accessory.  
If you require a non-standard instrument kit or 
accessory,  or  if  you  would  like  further 
information before making your choice, please 
contact our Sales or Products staff, or your local 
representative. 

 

Hire of Test Instruments 

Hire  of  our  test  instruments  can  be  arranged, 
subject to availability. Hire terms are typically on 
a weekly basis. Please contact our Sales staff 
or your local representative for details on pricing 
and availability. 
 

Test and repair service 

Where applicable, test instruments are shipped 
with  performance  test  results.  Details  of  the 
tests performed are listed with each product. No 
expiry  date  is  issued  with  these  results.  York 
EMC Services provides a retest service, if the 
customer  requires  updated  performance  data. 
Please refer to the order codes when requesting 
a quotation for this service. 
A  repair  service  covering  faulty  or  damaged 
York  EMC  Services  test  instruments  is 
available.  Each  case  is  examined  individually, 
with quotations for repair and retest issued as 
appropriate.  Please  contact  our  Sales  or 
Products staff or your local representative in the 
first instance. 
 

Sales Office Hours 

Our  UK  head  office  hours  are  9:00  –  17:00 
Monday to Thursday, 9:00 – 16:00 Friday. 
Tel: +44 0330 430 3456 
Email:  [email protected] 
A  current  list  of  York  EMC  Services 
representatives around the world can be found 
on  the  Test  Instrumentation  pages  of  our 
website: http://www.yorkemc.com 
 
Please  see  your  nearest  representative  for 
details of their opening times. 
 

Quotations 

All  quotations  issued  directly  by  York  EMC 
Services are in GBP. 
Unless  otherwise  stated,  our  quotations  are 
valid for 30 days. 
VAT  will  be  charged  at  the  standard  rate 
applicable at the time of invoice. 
 
 
 
 

Orders 

Orders  are  accepted  with  an  accompanying 
Purchase Order Number. 
 

Stocks 

Stock  availability  and  delivery  times  may 
fluctuate  with  market  conditions,  production 
capacity  and  any  additional  test  results 
requirements. Please check with our sales team 
for an update. 
 

Delivery 

Standard  delivery  is  28  days  from  receipt  of 
order unless otherwise specified. 
Orders  are  normally  shipped  by  courier  at  the 
rate  stated  on  the  quotation.  Alternatively  the 
customer  may  arrange  for  their  own  pick-up 
service. 
 

Payment Methods 

We can accept payment in GBP, US dollars or 
Euros  by  bank

 

transfer,  UK-drawn  cheque  or 

credit  card.  New  customers may  be  asked for 
payment  in  advance.  Existing  customers  are 
eligible for credit terms. 
 

Warranty 

All products are supplied with a one-year return-
to-base-warranty as standard, unless otherwise 
stated. 
Extended  warranty  terms  may  be  arranged, 
please ask our sales team for details. 
 

Terms and Conditions 

All  our  orders  are  subject  to  our  terms  and 
conditions.  Please  ask  our  sales  team  for  full 
details. 
 

Technical Data 

We  have  endeavoured  to  ensure  the 
information  in  this  manual  is  accurate  at  the 
time of publication. However, in the interests of 
product  advancement,  we  reserve  the  right  to 
improve,  refine 

and 

otherwise 

modify 

specifications without notice. E&OE. 
 

Online Brochure 

Our  website  is  the  definitive  source  for 
information  regarding  new  products,  updated 
specifications,  application  notes  and  more. 
Please  visit  http://www.yorkemc.com  for 
information regarding our Test Instrumentation, 
as well as for details of our accredited EMC Test 
laboratories,  Consultancy  and  Research 
operations and Training courses.

 

 

Содержание HFG02

Страница 1: ...C 024 Rev 3 Author D Cullen BEng Hons MSc CEng CMgr MIET MIEEE MCMI Test Instrumentation Manager Checked M S Anslow MEng CEng MIET MIEEE Senior Engineer Approved D Cullen BEng Hons MSc CEng CMgr MIET...

Страница 2: ...TORY SHEET Date Issue Pag Para Description 17 02 2017 1 0 1st issue 20 03 2017 2 0 p19 EUT graphs added 07 02 2018 3 0 Safety instructions updated UNCONTROLLED ELECTRONIC COPY Users should satisfy the...

Страница 3: ...year of the original purchase provided that York EMC Services examination discloses to its satisfaction that the product is defective York EMC Services may at its option replace the product in lieu of...

Страница 4: ...SUITABLE TEST EQUIPMENT CONNECTION TO THE PUBLIC MAINS DISTRIBUTION NETWORK IS NOT PERMITTED YORK EMC SERVICES LTD ASSUMES NO LIABILITY FOR ANY DAMAGE THAT MAY RESULT FROM THE USE OF THIS EQUIPMENT OU...

Страница 5: ...ENVIRONMENT 10 6 OPERATION 11 6 1 CONTROLS AND INDICATORS 11 6 2 SUPPLYING POWER TO THE HFG02 12 6 3 OPERATING MODES 12 6 4 ENABLING THE TEST 13 6 5 TEST SUPPLY INDICATORS 13 6 6 PERFORMING A TEST 14...

Страница 6: ...61000 3 3 flicker standards The HFG02 allows the user to periodically verify their test equipment and its operation together helping to ensure compliance with standards and laboratory quality procedur...

Страница 7: ...in types of real world EUT not covered by the generalised harmonics and flicker modes The HFG02 can be used with test systems operating at both 110 Vac and 230 Vac nominal supply voltages and with eit...

Страница 8: ...N OF SYMBOLS Symbols displayed on the product are listed below Caution Protective Earth Terminal Alternating current HFG02 power supply on HFG02 power supply off Direct current DC connector polarity E...

Страница 9: ...ent is drawn every alternate half cycle Dimmer Load current is drawn at every cycle between 90 180 and 270 360 phase angles Intermittent flicker Load current is drawn for varying length periods over a...

Страница 10: ...ensions not including captive leads Length 330 mm Width 320 mm Height 170 mm Weight 8 kg 4 6 Compliance Safety Low Voltage Directive 2014 35 EU EMC EMC Directive 2014 30 EU 4 7 Environment 4 7 1 Opera...

Страница 11: ...the temperature within the enclosure exceeds the preset limit In this state the test mode will be disabled and the HFG02 will wait until the temperature has dropped sufficiently before the test can be...

Страница 12: ...st is running the test is automatically disabled Mode Test Mode Setting Load Profile Description Flicker 8 3 8 6 Hz Produces Pst value of 1 above the pass limit defined in EN IEC61000 3 3 1 Hz Produce...

Страница 13: ...to be enabled Tests are automatically disabled if the Test Supply voltage or frequency are outside their permitted ranges Test Supply Voltage Voltage measured Display Indication 110 VAC LED 230 VAC L...

Страница 14: ...ote that if the Test Supply does not provide a safety earth connection as one of the conductors e g 2 pin Live and Neutral only then the Chassis Earth wiring stud on the front of the HFG02 must be con...

Страница 15: ...ee Table 2 If an invalid voltage or frequency is detected the test load operation will be disabled Test Enable display will be OFF The test load operation will also be disabled if the HFG02 detects to...

Страница 16: ...HFG02 Operation Manual York EMC Services Page 16 of 25 Doc No Y0321 DOC 024 Rev 3 Figure 6 Troubleshooting flowchart...

Страница 17: ...ted according to EN IEC 61000 3 3 is shown in Table 3 Flicker Mode Setting Load Operation Pst Plt 8 3 8 6 Hz 8 33 Hz flicker 50 Hz Test Supply detected 8 6 Hz flicker 60 Hz Test Supply detected 1 10 1...

Страница 18: ...Operation Manual York EMC Services Page 18 of 25 Doc No Y0321 DOC 024 Rev 3 Figure 8 Disturbances generated in Fluctuating Harmonics mode Figure 9 Disturbance generated in Fixed 10 Hz Interharmonics...

Страница 19: ...1 DOC 024 Rev 3 Figure 10 Disturbances generated in 5 Hz and 10 Hz Interharmonics modes 6 3 EUT Load Operation The typical disturbances generated by the HFG02 in each of the EUT modes is shown below F...

Страница 20: ...2 Operation Manual York EMC Services Page 20 of 25 Doc No Y0321 DOC 024 Rev 3 Figure 12 Half wave rectifier current profile Figure 13 Dimmer current profile Figure 14 Intermittent flicker voltage prof...

Страница 21: ...bration The HFG02 is supplied with a manufacturer s calibration certificate It is recommended that the HFG02 should be periodically checked to ensure damage or long term changes have not altered the o...

Страница 22: ...he safety protection provided Do not use the HFG02 outside its rated supply voltage or environmental ranges The HFG02 must be positioned in a way that allows full access to any on off switch on the Te...

Страница 23: ...g of EN61000 4 11 2004 Voltage dips short interruptions EN61000 4 4 2004 A1 2010 Fast Transient common mode AC mains port EN61000 4 5 2006 Surge AC mains port EN61000 4 6 2009 Conducted RF immunity AC...

Страница 24: ...ices for servicing by authorized personnel This equipment cannot be repaired by the user DO NOT attempt to open the case or disassemble the equipment Only York EMC Services trained service personnel w...

Страница 25: ...ee your nearest representative for details of their opening times Quotations All quotations issued directly by York EMC Services are in GBP Unless otherwise stated our quotations are valid for 30 days...

Отзывы: