FORM 201.28-N1 

ISSUE DATE: 7/25/2017

NOMENCLATURE

YVAA 044 3AXX 46 AA

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

T

N

A

R

E

G

I

R

F

E

R

 /

 

L

E

V

E

L

E

G

A

T

L

O

V

N

O

I

T

A

R

U

G

I

F

N

O

C

E

Z

I

S

 

E

M

A

R

F

E

P

Y

T

 

T

C

U

D

O

R

P

 

E

S

A

B

Y

: York

#

#

#

#

: Condenser code

1

7

: 200 / 3 / 60

#

: Development Level

V

: Variable Speed

  Screw

#

: Evaporator code

2

8

: 230 / 3 / 60

A

: Refrigerant R-134a

: Refrigerant R-513A

#

: Compressor code

4

0

: 380 / 3 / 60

A

: Air cooled

#

: Condenser fan & sound kit code

4

6

: 460 / 3 / 60

A

5

0

: 380-415 / 3 / 50

5

8

: 575 / 3 / 60

: Design Series

    4       2    

 : 400 / 3 / 60

TABLE 1 - 

SPLIT SHIP UNITS MODELS

UNIT  

MODEL

SYS 1 & 2  

FAN QTY

MAIN/SUB SECTION 

FAN QTY

MAIN SECTION 

SYS 2 FAN QTY

SYS 1 REF. QTY 

(LB/KG)

SYS 2 REF QTY 

(LB/KG)

0443   

1543

12/12

20/4

8

370/168

370/168

0483   

1693

13/13

20/6

7

385/175

385/175

0523   

1843

13/13

20/6

7

445/202

445/202

0425   

0475

14/10

20/4

6

480/217

365/165

0475   

1665

13/13

20/6

7

445/202

445/202

0368   

1288

14/8

18/4

4

475/215

320/145

0398   

1388

14/10

20/4

6

475/215

360/163

0428   

1488

14/12

20/6

6

475/215

385/175

Содержание HFC-134A

Страница 1: ...OCEDURE FOR YVAA PHASE C SPLIT SHIP UNITS WITH 22 TO 26 FANS AIR COOLED SCREW LIQUID CHILLERS INSTALLATION SUPERSEDES 201 28 N1 515 Form 201 28 N1 717 Issue Date July 25 2017 HFC 134A OR HFC 513A 50 A...

Страница 2: ...his document and any referenced materials This in dividual shall also be familiar with and comply with all applicable industry and governmental standards and regulations pertaining to the task in ques...

Страница 3: ...ision was made These revisions are to technical in formation and any other changes in spelling grammar or formatting are not included The Control VSD Cabinet contains lethal high AC and DC voltages Be...

Страница 4: ...or code 4 0 380 3 60 A Air cooled Condenser fan sound kit code 4 6 460 3 60 A 5 0 380 415 3 50 5 8 575 3 60 Design Series 4 2 400 3 60 Table 1 SPLIT SHIP UNITS MODELS UNIT MODEL SYS 1 2 FAN QTY MAIN S...

Страница 5: ...ly where building work is in progress The unit should be stored in a location where there is minimal activity in order to limit the risk of ac cidental physical damage To prevent inadvertent operation...

Страница 6: ...wly complete the removal from the container then lift up and away LD19197a LIFTING USING LUGS Units are provided with lifting holes in the base frame which accept the accessory lifting lug set as show...

Страница 7: ...Section Split A B C D E F G H Figure 1 UNIT AS ASSEMBLED Use these charts for lifting separated main section and sub section units individually SEE 035 23515 002 FOR RIGGING MAIN SECTION LIFT POINTS D...

Страница 8: ...3 4 Pump down the portion of the unit downstream of the ball valves in the main section the sub sec tion and the last condenser module in the main section Do not open discharge and liquid line ball va...

Страница 9: ...o sections LD19426 Discharge Line Ball Valve Liquid Line Ball Valve Figure 4 DISCHARGE LINE BALL VALVE LD19425 Split Unit Junction Box Figure 5 WIRING HARNESS ELECTRICAL CONNECTION 6 Perform continuit...

Страница 10: ...reedom Pennsylvania USA 17429 800 861 1001 Subject to change without notice Printed in USA Copyright by Johnson Controls 2017 www johnsoncontrols com ALL RIGHTS RESERVED Form 201 28 N1 717 Issue Date...

Отзывы: