TYPICAL INSTALLATION 

TYPICAL FIELD WIRING - 1 Phase Application

TYPICAL FIELD WIRING - 3 Phase Application

MINIMUM 18” SERVICE ACCESS
CLEARANCE ON ONE SIDE

60” OVERHEAD
CLEARANCE

10” CLEARANCE
COIL AREA

WEATHERPROOF
DISCONNECT
SWITCH

THERMOSTAT

TO FURNACE OR
AIR HANDLER
TERMINAL BLOCK

NEC CLASS 1 WIRING

NEC CLASS 2 WIRING

TO INDOOR COIL

SEAL OPENING(S) WITH
PERMAGUM OR EQUIVALENT

CONTROL ACCESS PANEL

NOTE: ALL OUTDOOR WIRING

MUST BE WEATHERPROOF.

ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES

POWER WIRING

208/230-1-60

CONTACTOR
TERMINALS

COIL

GND.

LUG

C

Y

R

G

W

Y

R

G

W

POWER WIRING
CONTROL WIRING
FACTORY WIRING

24 VOLT CONTROL WIRING
MINIMUM 18 GA. WIRE
(NEC CLASS 2)

FURNACE OR AIR HANDLER TERMINAL BLOCK

ROOM THERMOSTAT

CONDENSING UNIT

ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY.

TERMINAL W IS ONLY
REQUIRED ON SYSTEMS
WITH HEAT.

*

*

ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES

POWER WIRING

208/230-3-60

460-3-60

CONTACTOR
TERMINALS

COIL

GND.

LUG

C

Y

R

G

W

Y

R

G

W

POWER WIRING

CONTROL WIRING
FACTORY WIRING

24 VOLT CONTROL WIRING
MINIMUM 18 GA. WIRE
(NEC CLASS 2)

FURNACE OR AIR HANDLER TERMINAL BLOCK

ROOM THERMOSTAT

CONDENSING UNIT

ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY.

TERMINAL W IS ONLY
REQUIRED ON SYSTEMS
WITH HEAT.

*

*

Содержание H*RC018 THRU 060

Страница 1: ...is is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the compressor if undesirable operating condi tions occur A liquid line filter dr...

Страница 2: ...ed indoor coil and 15 feet of refrigerant tubing For tubing lengths other than 15 feet add or sub tract the amount of refrigerant using the difference in length multiplied by the per foot value PHYSIC...

Страница 3: ...2 12 702 0 703 0 G2FD048S H 21 24 84 73 16 78 10 87 11 702 16 702 10 703 11 G2FD060S H 24 90 87 15 703 15 703 20 G2FD061H24 90 87 19 703 19 703 25 G1HD024 59 53 5 59 4 701 5 701 4 G1HD036 69 59 13 63...

Страница 4: ...F048SOF 78 78 21 87 6 702 21 703 6 G1NF060SOF 87 87 18 703 18 703 0 F2RP024N06 61 53 4 59 4 701 4 701 4 F2RP030N06 65 59 6 63 4 701 6 701 4 F2RP036N06 75 63 4 73 8 701 4 702 8 F2RP042N06 78 73 13 78 0...

Страница 5: ...changed verify the evaporator nameplate has been marked with the correct orifice size Additional R 22 Charge Orifice Size for Various Matched Systems 3 Phase Outdoor Unit H1RC036S H1RC048S H1RC060S U...

Страница 6: ...18 21 G2FD048 S H 21 1400 43 0 30 6 13 00 11 55 N1VSC16 10 15 18 21 G2FD048 S H 21 1590 47 0 30 6 12 80 11 40 H2RC048S06 N1VSC16 10 15 18 21 G2FD048 S H 21 1590 47 0 34 9 12 80 12 80 11 40 N1VSD20 10...

Страница 7: ...11 00 17 G1FA048S17 1000 31 2 22 3 12 50 12 50 11 45 21 G1FA048S21 1000 31 2 22 3 12 50 12 50 11 35 G1HD036 1000 30 8 21 9 12 75 12 75 11 25 17 G1NA030S17K 1000 30 2 21 4 12 00 12 00 11 05 21 G1NA030S...

Страница 8: ...1FA048S21 1575 46 5 34 9 12 00 12 00 11 00 21 24 G1FA060S21 24 1575 48 0 36 0 12 50 12 50 11 10 G1HD048 1575 46 0 34 5 12 00 12 00 10 80 G1HD060 1575 47 5 35 6 12 40 12 40 11 05 21 G1NA048S21D 1575 46...

Страница 9: ...0 11 15 P1DUB16V G2FD036 S H 17 17 1200 34 4 24 2 12 25 11 40 P1DUC20V G1FA036S21 21 1200 33 6 23 6 12 00 11 30 P1DUC20V G2FD036 S H 21 21 1200 34 8 24 4 13 00 11 60 P1XDB12V G2FD036 S H 17 17 1130 34...

Страница 10: ...s for specific model number 2 TXV Use 1TV700 Series Kit 3 Variable speed furnaces have B O D Blower on Delay standard COOLING PERFORMANCE MODEL SUCT T P COMPR AIR TEMP ON CONDENSER MODEL SUCT T P COMP...

Страница 11: ...Stage only manual mechanical thermostat Add sub base for 1H 1C 1H 1C manual change over electronic non programmable thermostat 1H 1C auto manual changeover electronic programmable deluxe 7 day thermo...

Страница 12: ...30 1 60 CONTACTOR TERMINALS COIL GND LUG C Y R G W Y R G W POWER WIRING CONTROL WIRING FACTORY WIRING 24 VOLT CONTROL WIRING MINIMUM 18 GA WIRE NEC CLASS 2 FURNACE OR AIR HANDLER TERMINAL BLOCK ROOM T...

Страница 13: ...14 2 13 6 KW 1 47 1 45 1 43 1 48 1 47 1 45 1 49 1 48 1 46 105 T C 18 1 16 3 14 2 18 7 17 1 15 0 19 4 17 8 15 8 S C 11 3 10 6 9 7 13 0 12 2 11 3 14 7 13 8 12 9 KW 1 58 1 55 1 52 1 59 1 57 2 53 1 61 1 5...

Страница 14: ...6 2 07 2 02 1 98 2 09 2 04 2 00 115 T C 21 3 18 6 16 2 22 0 19 5 17 0 22 8 20 5 17 7 S C 14 0 12 9 12 0 16 3 15 3 14 2 18 6 17 8 16 4 KW 2 19 2 13 2 08 2 22 2 16 2 10 2 25 2 18 2 12 125 T C 19 8 16 4...

Страница 15: ...3 19 5 KW 2 70 2 61 2 55 2 74 2 64 2 57 2 77 2 68 2 59 125 T C 24 0 20 4 17 0 26 7 21 7 16 8 29 4 23 2 16 7 S C 17 1 15 6 14 1 20 2 17 9 16 0 23 3 20 5 17 8 KW 2 88 2 76 2 70 2 94 2 79 2 70 3 00 2 84...

Страница 16: ...2 22 6 28 4 25 5 22 9 S C 21 4 20 0 19 0 23 8 22 3 21 1 26 2 24 6 23 2 KW 3 36 3 29 3 19 3 38 3 31 3 23 3 39 3 33 3 26 NOTE ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH 10...

Страница 17: ...33 4 30 8 27 2 33 6 31 3 27 7 S C 23 7 22 5 20 7 24 5 23 6 21 9 25 4 24 6 23 0 KW 4 01 3 88 3 75 4 02 3 91 3 77 4 03 3 93 3 78 125 T C 31 0 27 6 23 5 31 1 28 1 24 1 31 3 28 5 24 4 S C 23 1 21 3 19 6 2...

Страница 18: ...37 4 43 9 41 5 38 1 44 2 42 0 38 9 S C 28 4 27 6 25 9 30 0 29 7 28 2 31 6 31 8 30 5 KW 3 39 3 38 3 36 3 39 3 38 3 36 3 40 3 39 3 37 115 T C 41 2 38 1 34 1 41 6 38 7 34 9 42 0 39 3 35 7 S C 27 8 26 7...

Страница 19: ...2 6 41 9 37 2 33 1 S C 30 5 28 3 26 3 33 1 30 5 28 4 35 7 32 8 30 5 KW 4 28 4 15 4 02 4 32 4 17 4 05 4 35 4 19 4 08 125 T C 36 3 31 3 28 5 36 9 31 9 28 8 37 6 32 5 29 1 S C 29 2 26 8 24 8 31 8 28 9 26...

Страница 20: ...6 2 42 5 39 3 36 2 S C 30 5 30 6 29 5 30 9 32 6 32 8 31 5 32 8 34 1 34 2 32 7 34 5 KW 4 67 4 45 4 25 4 03 4 72 4 49 4 30 4 09 4 74 7 53 4 34 4 18 115 T C 41 8 38 3 35 3 31 7 42 3 38 8 35 8 33 0 42 5 3...

Страница 21: ...38 8 43 1 42 6 41 6 KW 5 24 5 10 5 06 5 25 5 11 5 07 5 26 5 12 5 08 105 T C 58 1 54 6 50 0 58 9 55 7 51 3 59 7 56 8 52 7 S C 36 9 36 0 34 4 39 8 39 0 37 3 42 7 41 9 40 2 KW 5 86 5 72 5 63 5 87 5 74 5...

Страница 22: ...LOW HORIZONTAL AND DOWNFLOW Available with factory installed horizontal drain pan ADD ON COILS FOR FURNACE APPLICATIONS G1NA UNCASED UPFLOW G1FA FULL CASED UPFLOW AIR HANDLERS FOR NON FURNACE APPLICAT...

Страница 23: ...036 21137 003 Rev A 1102 Unitary Products Group 23 NOTES...

Страница 24: ...nge without notice Printed in U S A 036 21137 003 Rev A 1102 Copyright by York International Corp 2002 All rights reserved Supersedes 036 21137 002 Rev C 0602 Unitary 5005 Norman Products York OK Grou...

Отзывы: