York GY8S160E30UH21 Скачать руководство пользователя страница 10

106306-UUM-A-0205

10

Unitary Products Group

FIELD INSTALLED ACCESSORIES - NON-ELECTRICAL

ITEM

DESCRIPTION

MOTOR

1

MOTOR,DIRECT DRIVE BLOWER

2

MOTOR,VENTOR ASS’Y.

ELECTRICAL

3

CAPACITOR, RUN

 (5 MFD/370V)        [RC]

CAPACITOR, RUN 

(7.5MFD/370V)       [RC]

4

CONTROL, HIGH LIMIT (N-Model)
CONTROL, HIGH LIMIT (L-Model)

5

CONTROL, FURNACE             [FC]

6

IGNITER

7

SENSOR, FLAME

8

SWITCH, AIR PRESSURE      [1LP]

9

SWITCH, DOOR                      [SW]

10

TRANSFORMER

11

VALVE, GAS

12

SWITCH, FLAME ROLL-OUT 

[ROS 3]

12A

CONTROL, Flame Roll Out

 (2ea.)[ROS1,2]

13

CONTROL, AUX. LIMIT

(2 ea.)[LS2,LS3]

14*

FUSE (AT0-3)

AIR MOVING

15

HOUSING, BLOWER

16

WHEEL, BLOWER

FABRICATED PARTS

17

SHIELD, SECONDARY AIR

18*

BAFFLE, FLUE

19

BURNER, MAIN GAS

20

BRACKET, IGNITER

21

DECK, BLOWER (Rear)

22

DECK, FRONT

23

HEAT EXCHANGER ASS’Y 

24

MANIFOLD, GAS

25

PANEL, ACCESS (BURNERS)

26

PAN, BASE

27

PANEL, FRONT (Blower)    

28

PANEL, TOP

29

WRAPPER, INSULATED

30

CHANNEL, TOE PLATE

31*

FILTER

32

PLUG, WINDOW, CLEAR - .875”

33*

RETAINER, FILTER

34*

CLIP, SPRING 

(FILTER RETAINER)

35

BRACKET, ROLL-OUT SWITCH

MISCELLANEOUS

36

ORIFICE, BURNER (Natural #45)

37

PLATE, RESTRICTOR (N-Model)
PLATE, RESTRICTOR 

(L-Model Style C)

PLATE, RESTRICTOR

 (L-Model Style D)

38

COLLAR, FLUE

39

HANDLE, DOOR

40*

GASKET, RESTRICTOR PLATE

41

TUBING, SILICONE

42*

SPRING, DOOR

43*

DIAGRAM, WIRING 

44*

HARNESS, WIRING (MAIN)

45*

SCREEN, LO NOX (L-Model Style C)
SCREEN, LO NOX (L-Model Style D)
(Qty. req’d equals no. of burners)

ITEM

DESCRIPTION

NOTE:

*Not Shown

Major components and suggested stocking items are shown with shaded item number.

MODEL NO.

DESCRIPTION

USED WITH

1NP0805

PROPANE (LP) CONVERSION KIT

08, 12

1NP0806

PROPANE (LP) CONVERSION KIT

16, 20

1LN0802

LOW NOX KIT

ALL MODELS

1FF0110

 FILTER FRAME KIT

08 - 12

1FF0112

 FILTER FRAME KIT

16 - 20

1HA0802

HIGH ALTITUDE INSTRUCTION PACKET (DOES NOT INCLUDE ORIFICES)

ALL MODELS

REPLACEMENT PART CONTACT INFORMATION

This is a generic parts list. To request a complete parts list, refer to the contact information below:

• Visit our website at www.source1parts.com for the following information:

1. Search for a part or browse the catalog.

2. Find a dealer or distributor.

3. Customer Service contact information.

a. Click on the “Brand Links” button

b. Click on the “Customer Service” button

• You can contact us by mail. Just send a written request to:

York International

Consumer Relations

5005 York Drive

Norman, OK 73069

Содержание GY8S160E30UH21

Страница 1: ...ts that have been wet or the furnace if deemed necessary FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or prop erty damage Do not store or use...

Страница 2: ...furnace casing making sure the physical support is sound without sagging cracks or gaps Examine the furnace base making sure it is physically sound without cracks gaps or sagging and has a good seal...

Страница 3: ...Read the safety information above 2 Set the thermostat to the lowest setting 3 Turn off all electric power to the appliance 4 Remove furnace door 5 Move gas control switch to the OFF position Do not f...

Страница 4: ...th air filters Table 1 will indicate 2 filters by using brackets with the number two 2 2 After you determine the cabinet size and what return configuration you have look up the recommended filter size...

Страница 5: ...f the motor and wheel are heavily coated with dust they can be brushed and cleaned with a vac uum cleaner If the blower cannot be properly cleaned without removing it from the furnace then this servic...

Страница 6: ...tor plate assem bly to the vestibule panel The surface is also gasketed The assembly including the flue baffle plate rear may be vacuumed or cleaned with hot water if necessary 3 The upper portion of...

Страница 7: ...ated the number of times equal to the code For example six on flashes equals a number 6 fault code All flash code sequences are broken by a 2 sec ond off period SLOW GREEN FLASH Normal operation SLOW...

Страница 8: ...CODE STORAGE AND RETRIEVAL The control in this furnace is equipped with memory that will store up to five error codes to allow a service technician to diagnose problems more easily This memory will be...

Страница 9: ...ucts Group 9 SECTION III REPLACEMENT PARTS LIST NEUTRALS EAC COOL HEAT HUM PARK PARK L1 XFMR Y W R G C 37 36 28 43 46 2 25 9 4 45 7 33 38 34 8 15 1 16 32 5 27 6 3 39 22 23 18 31 14 35 29 10 47 41 44 1...

Страница 10: ...R N Model PLATE RESTRICTOR L Model Style C PLATE RESTRICTOR L Model Style D 38 COLLAR FLUE 39 HANDLE DOOR 40 GASKET RESTRICTOR PLATE 41 TUBING SILICONE 42 SPRING DOOR 43 DIAGRAM WIRING 44 HARNESS WIRI...

Страница 11: ...106306 UUM A 0205 Unitary Products Group 11 SECTION IV WIRING DIAGRAM FIGURE 12 Wiring Diagram...

Страница 12: ...nly to products installed in the United States and Canada EXCLUSIONS This warranty does not cover any 1 Shipping labor or material charges 2 Damages resulting from transportation installation or servi...

Отзывы: