background image

035-19657-002 Rev. A (0704)

2

Unitary Products Group

7.

NEVER . . .Store flammable materials of any kind near your fur-
nace. Gasoline, solvents, and other volatile liquids should be
stored only in approved containers outside your home. These
materials vaporize easily and are extremely dangerous.

8.

NEVER . . .Store cleaning materials near your furnace. Materials
such as bleaches, detergents, powdered cleansers, etc., can
cause corrosion of the heat exchangers. 

9.

NEVER . . . Use the area around your furnace as a storage area
for items which could block the normal flow of air. This flow of air is
required for ventilation of the various furnace components.

INSTRUCTIONS FOR EXAMINING THE FURNACE 

INSTALLATION

It is the owner’s responsibility to ensure that an annual inspection of the
entire heating portion of the unit is made by a qualified service agency.
Examine the furnace as outlined below in steps “1 - 6” before each
heating season. Use Figure 3 for visual reference.

1.

Examine the heat exchanger, vent pipe, combustion air passes
gas, vent connectors and chimney to be sure they are clear and
free of obstructions.

2.

Examine the vent pipe making sure it is firmly in place, that it
slopes slightly upward and is physically sound without holes and
all of the connections are secure.

3.

Examine the return-air duct connections to make sure they are
physically sound, sealed to the furnace casing, and the ducts ter-
minate outside the space containing the furnace.

4.

Examine the furnace casing making sure the physical support is
sound without sagging, cracks or gaps. Examine the furnace base
making sure it is physically sound without cracks, gaps or sagging
and has a good seal.

5.

Examine the furnace casing for obvious signs of deterioration.

6.

Examine the burner flames to make sure they are in good adjust-
ment. Refer to the pictorial sketch shown in Figure 2 as a compari-
son to the actual flame.

 FIGURE 1: 

Component Locations

FIRE OR EXPLOSION HAZARD

This furnace is designed and approved for use with Nat-
ural Gas and (LP) Propane Gas ONLY. DO NOT BURN
ANY LIQUID FUEL OR SOLID FUEL IN THIS FURNACE.

Burning any unapproved fuel will result in damage to the
furnace heat exchanger, which could result in Fire, Per-
sonal Injury, and/or Property Damage.

VENT PIPE

PRESUURE
SWITCH

SILICONE
TUBE

INDUCER
SHIELD

GAS VALVE

FLAME
SENSOR

INDUCED DRAFT
ASSEMBLY

INDUCED DRAFT
MOTOR

LIMIT
SWITCH

IGNITOR

MANIFOLD
PIPE

SAFETY SHUTOFF
SWITCH

CONTROL
BOARD

FLUE
COLLAR

ELECTRICAL
JUNCTION BOX

 FIGURE 2: 

Burner Flame Drawing

BLUE CONE PORTION OF FLAME SHOULD
ENTER HEAT EXCHANGER TUBE

 FIGURE 3: 

Furnace Examination Checkpoints

4 EXAMINE

FURNACE
CASING

6

5

3

4

3

1

6

EXAMINE
RETURN AIR
DUCT
CONNECTION

REMOVE
PANEL
TO EXAMINE
BURNER
FLAMES

EXTERNAL HEAT EXCHANGER INTERNAL

VENT COMBUSTION AIR PIPE. MUST

REMOVE PANEL TO EXAMINE.

EXAMINE ENTIRE
FURNACE CASING
SHOWN IN ALL
DRAWINGS

EXAMINE
RETURN AIR
DUCT
CONNECTION
(side or bottom)

REMOVE
PANEL
TO EXAMINE
BURNER
FLAMES

EXAMINE EXTERNAL
VENT PIPE

EXAMINE
FURNACE
CASING

Содержание FC8S

Страница 1: ...controls control system parts electrical parts that have been wet or the furnace if deemed necessary FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury d...

Страница 2: ...minate outside the space containing the furnace 4 Examine the furnace casing making sure the physical support is sound without sagging cracks or gaps Examine the furnace base making sure it is physic...

Страница 3: ...1 STOP Read the safety information above 2 Set the thermostat to the lowest setting 3 Turn off all electric power to the appliance 4 Remove furnace door 5 Move gas control switch to the OFF position D...

Страница 4: ...h velocity filters may be cleaned with a vacuum cleaner or washed with a garden hose Be sure to shake off excess water and allow filter to completely dry before re installing the filter Blower Care Ev...

Страница 5: ...gile and easily broken The lower portion of the heat exchanger will now be exposed To clean the burner assembly use a vacuum cleaner or remove the burn ers as outlined in burner cleaning and clean in...

Страница 6: ...result in a disruption in the flame and be sensed within 1 0 seconds The gas valve will de energize and the control will begin a recycle operation A normal ignition sequence will begin after a 15 sec...

Страница 7: ...ng problem Both heating and cooling operations will be affected Check polarity at furnace and branch Check furnace grounding Check that flame probe is not shorted to chassis 10 RED FLASHES Gas valve e...

Страница 8: ...ROPANE LP CONVERSION KIT 040 080 100 1NP0348 060 115 130 1PS0301 HIGH ALTITUDE PRESSURE SWITCH KIT Does Not Include Orifices SEE CHART BELOW 1PS0302 1PS0311 1PS0312 1BR0314 EXTERNAL BOTTOM RETURN FILT...

Страница 9: ...035 19657 002 Rev A 0704 Unitary Products Group 9 2 4 11 9 5 3 6 8 7 12 13 16 17 26 53 28 42 39 29 38 43 21 25 32 33 35 31 27 23 22 44 30 24 18 20 12A 7 35 24 36 12 19 11...

Страница 10: ...RNER Natural 45 38 PLATE RESTRICTOR 39 COLLAR FLUE 40 LO NOX SCREEN L Models Only MISCELLANEOUS 41 FILTER 75 X 16 X 25 42 SIGHT GLASS OVAL 43 GASKET RESTRICTOR PLATE 44 TUBING SILICONE 45 SHIELD INDUC...

Страница 11: ...035 19657 002 Rev A 0704 Unitary Products Group 11 SECTION IV WIRING DIAGRAM FIGURE 9 Wiring Diagram...

Страница 12: ...products installed in the United States and Canada EXCLUSIONS This warranty does not cover any 1 Shipping labor or material charges 2 Damages resulting from transportation installation or servicing 3...

Отзывы: