York FC Скачать руководство пользователя страница 12

258931-BTG-A-0606

12

Unitary Products Group

Coil - PC

Dimensions - PC Coils

Model

A

B

C

D

Refrigerant

Line Size

*

*

Refrigerant line sizes may require larger lines for extended line lengths. 
See York bulletin #690.01-AD1V for details.

Factory 

Installed 

TXV (R22)

Liquid Vapor

PC18A2AN1

14.5 17 3/4 13 3/8 13.5

3/8

3/4

2A

PC18A3XN1

14.5 17 3/4 13 3/8 13.5

3/8

3/4

None

PC18B2AN1

17.5

17

16 3/8 16.5

3/8

3/4

2A

PC18B3XN1

17.5

17

16 3/8 16.5

3/8

3/4

None

PC24A2AN1

14.5 21 7/8 13 3/8 13.5

3/8

3/4

2A

PC24A3XN1

14.5 21 7/8 13 3/8 13.5

3/8

3/4

None

PC24B2AN1

17.5 21 3/8 16 3/8 16.5

3/8

3/4

2A

PC24B3XN1

17.5 21 3/8 16 3/8 16.5

3/8

3/4

None

PC30A2AN1

14.5 21 7/8 13 3/8 13.5

3/8

3/4

2A

PC30A3XN1

14.5 21 7/8 13 3/8 13.5

3/8

3/4

None

PC30B2AN1

17.5 21 3/8 16 3/8 16.5

3/8

3/4

2A

PC30B3XN1

17.5 21 3/8 16 3/8 16.5

3/8

3/4

None

PC35B3XN1

17.5 18 7/8 16 3/8 16.5

3/8

3/4

None

PC35C3XN1

21

18 3/4 19 7/8

20

3/8

3/4

None

PC36A2AN1

14.5 23 7/8 13 3/8 13.5

3/8

7/8

2A

PC36A3XN1

14.5 23 7/8 13 3/8 13.5

3/8

7/8

None

PC36B2AN1

17.5 23 1/8 16 3/8 16.5

3/8

7/8

2A

PC36B3XN1

17.5 23 1/8 16 3/8 16.5

3/8

7/8

None

PC36C2AN1

21

22 7/8 19 7/8

20

3/8

7/8

2A

PC36C3XN1

21

22 7/8 19 7/8

20

3/8

7/8

None

PC42B2CN1

17.5 27 5/8 16 3/8 16.5

3/8

7/8

2C

PC42B3XN1

17.5 27 5/8 16 3/8 16.5

3/8

7/8

None

PC42C2CN1

21

27 1/8 19 7/8

20

3/8

7/8

2C

PC42C3XN1

21

27 1/8 19 7/8

20

3/8

7/8

None

PC48C2CN1

21

25 3/8 19 7/8

20

3/8

7/8

2C

PC48C3XN1

21

25 3/8 19 7/8

20

3/8

7/8

None

PC48D2CN1

24.5 24 5/8 23 3/8 23.5

3/8

7/8

2C

PC48D3XN1

24.5 24 5/8 23 3/8 23.5

3/8

7/8

None

PC60C2CN1

21

27 1/2 19 7/8

20

3/8

7/8

2C

PC60C3XN1

21

27 1/2 19 7/8

20

3/8

7/8

None

PC60D2CN1

24.5 26 7/8 23 3/8 23.5

3/8

7/8

2C

PC60D3XN1

24.5 26 7/8 23 3/8 23.5

3/8

7/8

None

PC coils are not available with a factory installed horizontal drain pan.
(3X) = Models require field installed TXV.

20

3/8”

(Openin

g)

A

C

(Opening)

12”

B

22”

BOTTOM
OPENING
DIMENSIONS

20 1/4”

D

COIL - UC

Dimensions - UC Coils

Model

Dimensions — Inches Refrigerant Connections

A

B

C

Line Size

Liquid

Vapor

UC18A3XN1

13

19.875

17

3/8

3/4

UC18A2AN1

UC18B3XN1

16

16.5

UC18B2AN1

UC24A3XN1

13

21

UC24A2AN1

UC24B3XN1

16

20.5

UC24B2AN1

UC30A3XN1

13

21

UC30A2AN1

UC30B3XN1

16

20.5

UC30B2AN1

UC36A3XN1

13

23.5

7/8

UC36A2AN1

UC36B3XN1

16

22.5

UC36B2AN1

UC36C3XN1

19.5

22

UC36C2AN1

UC42B3XN1

16

26.5

UC42B2CN1

UC42C3XN1

19.5

25.5

UC42C2CN1

UC48C3XN1

19.5

23.5

UC48C2CN1

UC48D3XN1

23

23

UC48D2CN1

UC60C3XN1

19.5

25.5

UC60C2CN1

UC60D3XN1

23

25

UC60D2CN1

B

C

A

Содержание FC

Страница 1: ...ed coils match the dimensions of the furnace or modular blower FEATURES Thermal Expansion Valve Provides flexibility to convert any coil to R22 or R410A refrigerant A true bolt on TXV valve assembly a...

Страница 2: ...5 4 31 6 27 6 67 33 9 30 3 26 8 23 0 62 27 3 23 7 22 5 18 0 57 22 6 20 1 17 5 14 8 FC35B PC35B FC35C PC35C 1025 72 46 1 41 9 37 4 33 0 67 36 9 32 6 28 6 24 3 62 28 9 24 2 26 4 19 7 57 24 7 22 9 21 1 1...

Страница 3: ...37 6 33 2 29 1 24 7 62 29 3 24 6 26 9 20 0 57 25 2 23 3 21 5 20 0 MC36A 1150 72 46 8 42 6 38 1 33 6 67 37 5 33 1 29 1 24 7 62 29 3 24 6 26 8 20 0 57 25 1 23 2 21 4 20 0 MC36B 1250 72 52 0 47 3 42 3 3...

Страница 4: ...57 71 2 61 4 51 3 41 1 See Condensing Unit or Heat Pump Technical Guide for Total Cooling Capacity and Sensible Capacity COOLING CAPACITY COIL ONLY Model Rated CFM Entering Air F Wet Bulb MBH EVAPORA...

Страница 5: ...0 72 35 2 32 0 28 6 24 8 67 32 4 28 6 25 3 21 9 62 26 6 23 6 21 5 18 7 57 25 2 22 7 20 2 17 6 UC36A 1150 72 46 8 42 7 37 9 33 0 67 43 1 39 2 34 9 30 4 62 35 3 32 1 28 6 24 9 57 33 3 26 9 26 9 23 4 UC3...

Страница 6: ...C42B PC42B 1200 0 21 1400 0 28 1600 0 34 1800 0 40 FC42C PC42C 1200 0 14 1400 0 19 1600 0 24 1800 0 28 FC48C PC48C 1600 0 29 1800 0 35 2000 0 40 2200 0 46 FC48D PC48D 1600 0 25 1800 0 30 2000 0 35 220...

Страница 7: ...600 0 35 1800 0 41 MC48D 1200 0 20 1400 0 26 1600 0 31 1800 0 36 MC60D 1600 0 27 1800 0 33 2000 0 38 2200 0 44 MC61D 1600 0 24 1800 0 29 2000 0 35 2200 0 40 UNCASED UPFLOW A TYPE Model Airflow Wet Coi...

Страница 8: ...N1 4 38 2 14 2 18 x 17 5 2A 50 42 FC35B3XN1 PC35B3XN1 3 9 3 12 2 16 x 17 5 None 53 45 FC35C3XN1 PC35C3XN1 3 9 3 12 2 16 x 17 5 None 55 46 FC36A3XN1 PC36A3XN1 4 86 2 14 2 20 x 17 5 None 51 44 FC36A2AN1...

Страница 9: ...g Heat Pump Sweat 3 67 2 14 2 16 x 16 5 1 x 0 866 3 8 Enhanced None 18 UC18A2AN1 2A UC18B3XN1 3 67 2 14 2 16 x 16 5 None 20 UC18B2AN1 2A UC24A3XN1 4 58 2 14 2 20 x 16 5 None 22 UC24A2AN1 2A UC24B3XN1...

Страница 10: ...B2AH1 2A MC36C3XH1 4 86 2 14 2 20 x 17 5 None 65 MC36C2AH1 2A MC42B3XH1 5 83 2 14 2 24 x 17 5 None 72 MC42B2CH1 2C MC42C3XH1 5 83 2 14 2 24 x 17 5 None 72 MC42C2CH1 2C MC48C3XH1 5 35 3 12 2 22 x 17 5...

Страница 11: ...lled horizontal drain pan 3X Models require field installed TXV 20 3 8 Opening A C 3 4 Flange B 22 BOTTOM OPENING DIMENSIONS D 20 1 4 Coil FC Dimensions FC Coils Model A B C D Refrigerant Line Size Re...

Страница 12: ...3 8 7 8 2A PC36C3XN1 21 22 7 8 19 7 8 20 3 8 7 8 None PC42B2CN1 17 5 27 5 8 16 3 8 16 5 3 8 7 8 2C PC42B3XN1 17 5 27 5 8 16 3 8 16 5 3 8 7 8 None PC42C2CN1 21 27 1 8 19 7 8 20 3 8 7 8 2C PC42C3XN1 21...

Страница 13: ...onnections A B C D Line Size Liquid Vapor HD24A H1 28 3 4 24 23 3 4 21 5 8 3 8 3 4 HD36B H1 28 3 4 28 23 3 4 25 5 8 7 8 HD48C H1 34 3 4 28 29 3 4 25 5 8 HD60D H1 34 3 4 30 29 3 4 27 5 8 COIL HC B 19 1...

Страница 14: ...258931 BTG A 0606 14 Unitary Products Group NOTES...

Страница 15: ...258931 BTG A 0606 Unitary Products Group 15 NOTES...

Страница 16: ...without notice Printed in U S A 258931 BTG A 0606 Copyright by York International Corp 2006 All rights reserved Supersedes 251366 036 21668 001 Rev B 0306 Unitary 5005 Norman Products York OK Group D...

Отзывы: