
246747-YTG-L-0808
4
Johnson Controls Unitary Products
COOLING CAPACITY - With Air Handler Coils
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
COOLING
MODEL
W
STAGE
RATED
CFM
NET MBH
SEER
EER
CZE02411
AV24
17
–
1
650
18.5
14.9
15.00
12.70
2
825
24.0
19.0
12.00
AV36
21
–
1
625
18.5
14.9
15.00
13.20
2
800
24.0
19.0
12.50
MV12B
17
FC/MC36B
1
650
18.5
14.9
15.00
13.20
2
825
24.0
19.0
12.50
CZE03611
AV36
21
–
1
830
25.0
17.5
15.00
12.70
2
1200
35.0
25.4
12.15
AV/SV48
24
–
1
810
23.8
17.5
15.25
13.20
2
1200
36.0
26.3
12.50
MV12B
17
FC/MC42B
1
775
23.8
17.5
15.25
12.40
2
1200
35.0
26.3
12.00
MV16C
21
FC/MC48C
1
775
25.4
18.7
15.50
13.20
2
1185
36.0
27.2
12.50
MV12D
24
FC/MC48D
1
775
25.4
18.8
15.75
13.25
2
1185
36.0
27.2
12.50
MV20D
24
FC/MC48D
1
775
25.4
18.8
15.75
13.25
2
1185
36.0
27.2
12.50
CZE04811
AV/SV48
24
–
1
1130
33.4
25.1
15.00
13.20
2
1600
47.0
36.6
12.50
F*FV060
24
–
1
1000
33.4
25.1
15.75
13.20
2
1600
47.0
36.6
12.50
MV20D
24
FC/MC60D
1
1000
33.4
25.1
15.50
13.15
2
1600
47.0
36.6
12.50
MV20D
24
MC61D
1
1000
33.6
25.3
16.00
13.30
2
1560
47.0
37.1
12.50
CZE06011
AV/SV60
24
–
1
1145
39.0
29.5
13.75
11.60
2
1845
54.0
42.4
11.00
F*FV060
24
–
1
1200
39.0
29.5
13.75
11.60
2
1845
55.0
42.4
11.00
MV20D
24
FC/MC60D
1
1200
39.0
29.5
13.50
11.70
2
1845
54.5
42.5
11.00
MV20D
24
MC61D
1
1180
39.5
29.7
14.00
11.90
2
1850
55.0
42.7
11.50
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8
0
°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.