background image

036-21610-001 Rev. A (0804)

6

Unitary Products Group

ACCESSORIES

PROPANE
CONVERSION KIT -- 1NP0347 (32, 64 & 80 MBH)

1NP0348 (48, 92,& 104 MBH)

This accessory conversion kit may be used to convert natural
gas units for propane (LP) operation at altitudes up to 2,000
ft. Conversion should be made by qualified distributor or
dealer personnel.

COMBUSTIBLE FLOOR BASE

1CB0314 = 

For 14-1/4" cabinet models

1CB0317 

= For 17-1/2" cabinet models

1CB0321 

= For 21" cabinet models

1CB0324 

= For 24-1/2" cabinet models

HIGH ALTITUDE PRESSURE SWITCH

These accessory kits may be used to convert units for high
altitude operation. Conversion must be made by qualified dis-
tributor or dealer personnel.

HIGH ALTITUDE PRESSURE SWITCH USAGE

Input (MBH)

Output (MBH)

2,000 Ft. to 

5,500 Ft.

>5,500 To 10,000 Ft.

40

32

1PS0301

1PS0301

57

46

1PS0301

1PS0301

80

64

1PS0302

1PS0301

100

80

1PS0312

1PS0311

115

92

1PS0312

1PS0311

130

104

1PS0312

1PS0311

FIELD INSTALLED ACCESSORIES - ELECTRICAL

 

MODEL NO.

DESCRIPTION

USED WITH

2TB17700424

SUBBASE (24V) -One-stage Heat / Cool.  Manual changeover.      

System Switch: Cool-Off-Heat. Fan Switch: Auto-On.

ALL MODELS

2TH13700424

THERMOSTAT-One-stage Heat.  Deluxe 24V with heat only subbase, 

does not include fan switch. NOTE: For one-stage cool or one-stage 

heat/cool, must be used with subbase 2TB17700424.

ALL MODELS

2ET03700324

THERMOSTAT- Hardwired, 1Heat / 1 Cool. Manual changeover, Sys-

tem Switch: Cool-Off-Heat. Fan Switch: Auto-On.

ALL MODELS

2ET03701224

THERMOSTAT-Power Stealing, 1Heat / 1 Cool.  Manual changeover,    

System Switch: Cool-Off-Heat. Fan Switch: Auto-On.

ALL MODELS

2ET03700124

THERMOSTAT-Hardwired, 1 Heat / 1Cool. Programmable, Auto 

changeove. System Switch: Cool-Off-Heat. Fan Switch: Auto-On.

ALL MODELS

2ET03701024

THERMOSTAT-Power Stealing,1 Heat / 1 Cool. Programmable, Auto 

changeover. System Switch:Cool-Off-Heat. Fan Switch: Auto-On.

ALL MODELS

2TC03700124

TWINNING CONTROL

ALL MODELS

Содержание AFFINITY PS8

Страница 1: ...tegory I listed and may be common vented with another gas appliance as allowed by the National Fuel Gas Code WARRANTY 20 year limited warranty on the heat exchanger 10 year heat exchanger warranty on...

Страница 2: ...3 4 100 80 1200 B 17 1 2 16 1 4 13 1 8 4 0 11 5 8 3 3 4 100 80 2000 C 21 19 3 4 16 5 8 4 0 13 3 8 3 3 4 115 92 1600 C 21 19 3 4 16 5 8 4 0 13 3 8 3 3 4 115 92 2000 C 21 19 3 4 16 5 8 4 0 13 3 8 3 3 4...

Страница 3: ...0 14 1 2 80 0 35 65 80 64 1600 17 1 2 80 0 25 55 100 80 1200 17 1 2 80 0 40 70 100 80 2000 21 80 0 25 55 115 92 1600 21 80 0 35 65 115 92 2000 21 80 0 30 60 130 104 2000 24 1 2 80 0 40 70 Input MBH Ma...

Страница 4: ...1060 1030 980 920 835 680 520 MED LOW 845 840 830 815 790 750 670 595 480 320 LOW 675 665 660 645 620 585 530 455 360 255 80 64 1600 B HIGH 1970 1935 1900 1850 1795 1735 1660 1590 1495 1395 MED 1445...

Страница 5: ...tem static is 0 58 w c To determine the system airflow com plete the following steps 1 Obtain the airflow values at 0 50 0 60 ESP Airflow 0 50 2120 CFM Airflow 0 60 2040 CFM 2 Subtract the airflow 0...

Страница 6: ...100 80 1PS0312 1PS0311 115 92 1PS0312 1PS0311 130 104 1PS0312 1PS0311 FIELD INSTALLED ACCESSORIES ELECTRICAL MODEL NO DESCRIPTION USED WITH 2TB17700424 SUBBASE 24V One stage Heat Cool Manual changeov...

Страница 7: ...036 21610 001 Rev A 0804 Unitary Products Group 7 NOTES...

Страница 8: ...to change without notice Printed in U S A 036 21610 001 Rev A 0804 Copyright by York International Corp 2004 All rights reserved Supersedes Nothing Unitary 5005 Norman Products York OK Group Drive 730...

Отзывы: