4 - Program the thermostat (Cont’d)

1. Press the 3 HOUR OCCUPIED key to change the unoccupied

temperature setting to the occupied setpoint for three hours.

Note : The program indicator will point to 3 HR OCCUPIED while

the override is in effect.

3 hour occupied with + or - Key

When using the + or - key with the 3 HOUR OCCUPIED key, the
+ or - key has a preassigned value of 0 to 3

°

C (default is 0). Use

the following steps to check or change the value:

1. Press the 3 HOUR OCCUPIED key.  The program indicator

will point to 3 HR OCCUPIED.

2. Press the DISPLAY key. The LCD will show a number from 0

to 3.

3. Press the + or - key to change the value.

4. Press the DISPLAY key to return to the program.

Set 3 hour occupied Override With + or - Key

The 3 HOUR OCCUPIED key with the + or - key will override the
unoccupied program for three hours with the occupied tempera-
ture se/- the preassigned key value (see Set + or - Key
Value section).

1. Press the 3 HOUR OCCUPIED key to change the unoccupied

temperature setting to the occupied setpoint for three hours.

2. Press the + key to increase or press the - key to decrease the

occupied setpoint by the key value.

Example : Unoccupied setpoint is 17

°

C, occupied setpoint is

21

°

C and key value is 1,7

°

C. Pressing the 3 HOUR

OCCUPIED key and the + key will change the set-
point from 17

°

C to 21

°

C plus 1,7

°

C or ~23

°

C.

Pressing the - key would change the setpoint to
21

°

C minus 1,7

°

C or ~19

°

C.

Note : The program indicator will point to 3 HR OCCUPIED

while the override is in effect. The LCD will not reflect the
key value.

4.9 - Cont Unoc

The continuous unoccupied override feature holds the setpoint at
the unoccupied temperature setpoint until the DISPLAY or CONT
UNOC key is pressed.  This override is used when the area will
be closed for a temporary period such as a long holiday.

1. Press the CONT UNOC key to hold the temperature at the

unoccupied setpoint.

2. Press the CONT UNOC key again to return to the program.

Содержание 2ET04700224

Страница 1: ...USER GUIDE Programmable Thermostat 2ET04700224 324 424 Roof Top units THERMOSTATS...

Страница 2: ...battery 5 3 Wiring 6 3 1 Connections between thermostat and equipment terminals 2ET04700224 6 3 2 Connections between thermostat and equipment terminals 2ET04700324 6 3 3 Connections between thermosta...

Страница 3: ...per hour rather than jumping from the energy savings setting to the comfort setting all at once This provides additional energy savings When the Intelligent RecoveryTM is used in the heating mode the...

Страница 4: ...this operation remove battery for 15 minutes and begin The thermostat is factory set for conventional system control If using with a heat pump 2ET04700324 or 424 locate the mini jumper on the back of...

Страница 5: ...ored the system will resume normal operation Without the battery the system will adopt the default setpoints Refer to the technical data Use the following steps to install a battery 1 Locate the batte...

Страница 6: ...from terminals 8 and 10 on jumper plug connector P7 4 Only required on units with supplemental electric heat 3 3 Connections between thermostat and equipment terminals 2ET04700424 Note Use copper con...

Страница 7: ...start time for the selected day repeat Step 5 until four dashes are displayed or the second start time if previously programmed is displayed Then repeat Step 6 9 Repeat Steps l through 8 for each rema...

Страница 8: ...eassigned key value see Set or Key Value section 1 Press the 3 HOUR OCCUPIED key to change the unoccupied temperature setting to the occupied setpoint for three hours 2 Press the key to increase or pr...

Страница 9: ......

Страница 10: ...Europe Simplified Diagram Notes CUSTOMER INSTALLATION UNITARY equipment...

Страница 11: ......

Страница 12: ...Printed in France Manufacturer reserves the right to change specifications without prior notice E UG R9702 Europe...

Отзывы: