York 110 Скачать руководство пользователя страница 6

Compatibility Options / Accessories / Models

STANDARD

LOW BODY

LASER

CONCEALED

Code 

designation

YLV

YLH

YLV-AF 

YLH-AF

YLIV

YLIH

YLIV-AF  YLIH-AF

YLVR

YLIVR

Coils and heaters**

BA1**

Additionnal 1 row heating

l

l

l

l

l

l

l

l

l

l

KREL**

Kit electrical heater with safety thermostat and relay

l

l

l

l

l

l

l

l

Factory fitted thermostat

CSL00

Fan speed selector (buit in) 

l

l

l

l

l

l

l

l

l

l

CML00

Thermostat with manual fan speed and S/W change 
over (buit in)

l

l

CEL00 

Thermostat with manual fan speed, dead band, 
automatic change over (buit in)

Compatible with electrical heaters

l

l

CEL20 

Thermostat with automatic fan speed, dead band, 
automatic change over (buit in)

Compatible with electrical heaters

l

l

CEL30

Thermostat with automatic fan speed, dead band, 
automatic change over for modulating valves (buit in)

l

l

Remote controllers and thermostats

CSR00

Fan speed selector (wall mounted) 

l

l

l

l

l

l

l

l

l

l

CMR00

Thermostat with manual fan speed and S/W change 
over (wall mounted)

l

l

CER00 

Thermostat with manual fan speed, dead band, 
automatic change over (buit in)

Compatible with electrical heaters

l

l

CER20

Thermostat with automatic fan speed, dead band, 
automatic change over (buit in)

Compatible with electrical heaters

l

l

CER30

Thermostat with automatic fan speed, dead band, 
automatic change over for modulating valves (buit in)

l

l

CBL20

Parallel connection for ON/OFF valve

l

l

l

l

l

l

l

l

l

l

CBL30

Parallel connection for modulating valve 

l

l

l

l

l

l

l

l

l

l

Valves / Condensate pump / Water sensor / Minimum temperature thermostat (Factory fitted)

J3A2 (2p) 

3-way 4-ports on/off valves for 2-pipe systems

l

l

l

l

l

l

l

l

l

l

J3A2 (4p) 

3-way 4-ports on/off valves for 4-pipe systems

l

l

l

l

l

l

l

l

l

l

J3AM (2p) 

3-way 4-ports modulating valves for 2-pipe systems

l

l

l

l

l

l

l

l

l

l

J3AM (4p) 

3-way 4-ports modulating valves for 4-pipe systems

l

l

l

l

l

l

l

l

l

l

DT (2p) 

Shut-off valves for 2-pipe systems 
(in addition to J3A2/J3AM valves)

l

l

l

l

l

l

l

l

l

l

DT (4p) 

Shut-off valves for 4-pipe systems 
(in addition to J3A2/J3AM valves)

l

l

l

l

l

l

l

l

l

l

PC

Condensate pump

l

l

l

l

l

l

l

l

l

l

WS

Water sensor

Compatible with CEL/CER

TM

Minimum temperature thermostat

l

l

l

l

l

l

l

l

l

l

Feets and panels

CP1 

Set of painted feet

l

l

ZL1 

Set of feet + frontal socle

l

l

PPV1 

Vertical painted back panel

l

l

l

PPH1 

Horizontal painted back panel

l

l

External air intake

PA

Air intake plenum

l

PAS

Air intake plenum collars

l

PA90°

90° air intake plenum

l

RCA 

Air intake duct fitting

l

PM 

Air delivery plenum with collars

l

l

l

l

l

PM90 

90° air delivery plenum

l

l

l

l

l

    

l

 

Compatible 

 

 

 

 

 

 

 

 

Compatible with conditions

 

Not compatible

** 

Maximum of rows is indicated in the documentation, the maximum number of rows includes the heating row or electrical heater. 

Compatibility tables for FCU

LASER and LOW BODY