![York International RHP Series Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/york-international/rhp-series/rhp-series_technical-manual_3512302011.webp)
5612272-UTG-H-1221
Johnson Controls Ducted Systems
11
— = Not Applicable.
Furnaces that are listed individually in the above table use Coil Only Ratings.
RHP14L30B23S
CF/CM36D
24.5
800 - 1200
1000
29.6
23.6
14.00
12.00
30.0
20.6
8.55
6.80
4.16
2.80
RHP14L30B23S
CF/CM42D
24.5
800 - 1200
1000
29.2
21.8
14.00
12.00
29.2
19.6
8.50
—
3.74
2.60
RHP14L30B23S
CF30BBBA1
17.5
800 - 1200
1000
29.0
23.4
14.00
11.75
30.0
20.0
8.55
7.15
3.74
2.62
RHP14L30B23S
CM30BBBA1
17.5
800 - 1200
1000
29.0
23.4
14.00
11.75
30.0
20.0
8.55
7.15
3.74
2.62
RHP14L30B23S
XAF/XAUB30C
17.5
800 - 1200
1000
28.4
21.9
14.00
11.50
29.0
19.1
8.20
6.60
3.40
2.28
RHP14L30B23S
XAFC30C
21.0
800 - 1200
1000
28.4
21.9
14.00
11.50
29.0
19.1
8.20
6.60
3.40
2.28
RHP14L30B23S
XAHB30C
17.5
800 - 1200
1000
28.0
21.9
14.00
11.50
29.0
19.3
8.20
6.60
3.48
2.36
RHP14L30B23S
XAHC30C
21.0
800 - 1200
1000
28.0
21.9
14.00
11.50
29.0
19.3
8.20
6.60
3.48
2.36
RHP14L36B23S
CF/CM/CU48C
21.0
1000 - 1400
1200
36.0
28.7
14.25
12.20
35.8
23.4
8.50
7.75
3.54
2.46
RHP14L36B23S
CF/CM/CU48D
24.5
1000 - 1400
1200
36.0
28.7
14.25
12.20
35.8
23.4
8.50
7.75
3.54
2.46
RHP14L42B24S
CF/CM/CU48C
21.0
1200 - 1600
1400
40.5
31.9
14.00
11.25
40.5
26.0
8.20
7.30
3.32
2.54
RHP14L42B24S
CF/CM/CU48D
24.5
1200 - 1600
1400
40.5
31.9
14.00
11.25
40.5
26.0
8.20
7.30
3.32
2.54
RHP14L42B24S
CF48CBCA1
21.0
1200 - 1600
1400
40.5
31.9
14.00
11.25
40.5
26.0
8.20
7.30
3.32
2.54
RHP14L42B24S
CM48CBCA1
21.0
1200 - 1600
1400
40.5
31.9
14.00
11.25
40.5
26.0
8.20
7.30
3.32
2.54
RHP14L42B24S
CM48DBCA1
24.5
1200 - 1600
1400
40.5
31.9
14.00
11.25
40.5
26.0
8.20
7.30
3.32
2.54
RHP14L48B23S
CF/CM/CU60C
21.0
1400 - 1800
1600
47.0
33.0
14.00
12.00
47.5
35.2
8.20
—
4.04
2.96
RHP14L48B23S
CF/CM/CU60D
24.5
1400 - 1800
1600
47.0
33.0
14.00
12.00
47.5
35.2
8.20
—
4.04
2.96
For rated condition information, see the footnotes below the System Capacity - Single Piece and Modular Air Handlers table.
1. Systems matched with furnaces or air handlers not equipped with blower-off delays may require 60 second time delay.
SYSTEM CAPACITY - Upflow, Downflow and Horizontal Furnaces and Coils (Coil Only Ratings) (Continued)
UNIT MODEL
COIL
CFM RANGE
(MIN.-MAX.)
COOLING
HEATING
MODEL
WIDTH
RATED
CFM
NET MBH
SEER
1
EER
NET MBH
HSPF
Region IV
HSPF
Region V
COP
TOTAL
SENS.
47°F OD
17°F OD
47°F OD
17°F OD