TABLE 8: R-22 Saturated Properties

Pressure 

PSIG 

Temp °F 

Pressure 

PSIG 

Temp °F 

Pressure 

PSIG 

Temp °F 

Pressure 

PSIG 

Temp °F 

Pressure 

PSIG 

Temp °F 

Pressure 

PSIG 

Temp °F 

80  48 110 64 140 78 170 91 200 101 230 111 
82  49 112 65 142 79 172 91 202 102 232 112 
84  50 114 66 144 80 174 92 204 103 234 112 
86  51 116 67 146 81 176 93 206 103 236 113 
88  52 118 68 148 82 178 94 208 104 238 114 
90  54 120 69 150 83 180 94 210 105 240 114 
92  55 122 70 152 84 182 95 212 105 242 115 
94  56 124 71 154 84 184 96 214 106 244 115 
96  57 126 72 156 85 186 97 216 107 246 116 
98  58 128 73 158 86 188 97 218 107 248 117 

100 59 130 74 160 87 190 98 220 108 250 117 
102 60 132 75 162 88 192 99 222 109 252 118 
104 61 134 76 164 88 194 99 224 109 254 118 
106 62 136 77 166 89 196 100 226 110 256 119 
108 63 138 78 168 90 198 101 228 111 258 119 

Содержание CMB SERIES

Страница 1: ...result in minor or moderate injury It is also used to alert against unsafe practices and hazards involving only property dam age INSPECTION As soon as a unit is received it should be inspected for po...

Страница 2: ...tion of a 100 activated alumina suction line filter drier in the suction line is required in addition to the factory installed liquid line drier Operate the system for 10 hours Monitor the suction dri...

Страница 3: ...oft solder The outdoor units have reusable service valves on both the liquid and vapor connections The total system refrigerant charge is retained within the outdoor unit during shipping and installat...

Страница 4: ...System Charge section for checking and recording system charge SECTION IV INSTALLATIONS REQUIRING AN ADD ON TXV KIT For installations requiring a TXV kit refer to the Installation Instructions accomp...

Страница 5: ...at with permagum or equivalent to prevent air drafts affecting the operation of in the thermostat DEHUMIDIFICATION CONTROL A dehumidification control accessory 2HU06700124 may be used with variable sp...

Страница 6: ...0124 PP11C70224 THERMOSTAT THERMOSTAT THERMOSTAT AC5 Thermostat Installer Setup Number 1 System Type must be set to 0 Selection of GAS ELEC switch on thermostat not necessary Clipping Jumper W914 for...

Страница 7: ...Total system charge is determined as follows 1 Determine outdoor unit charge from tabular data sheet 2 Determine indoor coil adjustment from tabular data sheet 3 Calculate the line charge using the ta...

Страница 8: ...he liquid line at the outdoor unit will feel warm to the touch Instructing the Owner Assist owner with processing warranty cards and or online registration Review Owners Guide and provide a copy to th...

Страница 9: ...3 15 286 15 289 15 115 300 15 301 15 304 15 307 15 120 319 14 320 15 323 15 326 14 125 338 14 339 14 342 14 345 14 TABLE 5 3 1 2 Ton Subcooling Charging Chart Outdoor Ambient Indoor Wet Bulb F 57 62 6...

Страница 10: ...112 86 51 116 67 146 81 176 93 206 103 236 113 88 52 118 68 148 82 178 94 208 104 238 114 90 54 120 69 150 83 180 94 210 105 240 114 92 55 122 70 152 84 182 95 212 105 242 115 94 56 124 71 154 84 184...

Страница 11: ...163911 UIM A 0106 Unitary Products Group 11 SECTION IX WIRING DIAGRAM FIGURE 9 Wiring Diagram...

Страница 12: ...to change without notice Printed in U S A 163911 UIM A 0106 Copyright by York International Corp 2006 All rights reserved Supersedes NothingNothing Unitary 5005 Norman Product York OK Group Drive 7306...

Отзывы: