York International CMB SERIES Скачать руководство пользователя страница 1

163911-UIM-A-0106

R-22
OUTDOOR SPLIT-SYSTEM 
AIR CONDITIONING

MODELS: 13 SEER - CMB / AC3A / AL3A SERIES
1-1/2 TO 5 TONS

INSTALLATION MANUAL

LISTED

ISO 9001

Certified Quality

Management System

CERTIFICATION APPLIES ONLY

WHEN THE COMPLETE

SYSTEM IS LISTED

WITH ARI.

R

N

E

M

P

I

U

Q

E

T

Y

R

AT

I

N

U

0

1

2

A R

I

R

A

D

N

A

T

S

D

I

S

N

O

T

C

E

S

F

O

C

C

I

F

I

T

R

E

N

O

I

T

A

HT

I

W

C

G N

I

YL

P

M

O

S

A

I

R

A

O

T

D

E

I

F

I

T

R

E

C

R

E

R

UT

C

A

F

U

N

A

M

C

-

G

NI

N O

I

TI

D

N

O

R

I

A

SECTION I: GENERAL

The outdoor units are designed to be connected to a matching indoor
coil with sweat connect lines. Sweat connect units are factory charged
with refrigerant for a matching indoor coil plus 15 feet of field supplied
lines.

Matching indoor coils are available with a thermal expansion valve only.
The refrigerant charge may need to be changed for some indoor-out-
door unit combinations, elevation differences or total line lengths. Refer
to Application Data covering “General Piping Recommendations and
Refrigerant Line Length” (Part Number 036-61920-001).

SECTION II: SAFETY

This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.

Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.

DANGER  indicates an imminently hazardous situation, which, if not
avoided, will result in death or serious injury.

WARNING  indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury.

CAUTION  indicates a potentially hazardous situation, which, if not
avoided  may result in minor or moderate injury. It is also used to
alert against unsafe practices and hazards involving only property dam-
age.

INSPECTION

As soon as a unit is received, it should be inspected for possible dam-
age during transit. If damage is evident, the extent of the damage
should be noted on the carrier’s delivery receipt. A separate request for
inspection by the carrier’s agent should be made in writing. See Local
Distributor for more information.

Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service or mainte-
nance can cause injury or property damage. Refer to this manual
for assistance or for additional information, consult a qualified con-
tractor, installer or service agency.

This product must be installed in strict compliance with the
enclosed installation instructions and any applicable local, state,
and national codes including, but not limited to building, electrical,
and mechanical codes.

TABLE OF CONTENTS

GENERAL  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
UNIT INSTALLATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INSTALLATIONS REQUIRING AN ADD-ON TXV KIT . . . . . . . . . . . . 4
ELECTRICAL CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

EVACUATION   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
SYSTEM CHARGE   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
SYSTEM START-UP  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
WIRING DIAGRAM   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

LIST OF FIGURES

Typical Installation with Required Clearances  . . . . . . . . . . . . . . . . . . . 2
Tubing Hanger  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Underground Installation   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Heat Protection   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Typical Field Wiring   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Thermostat Chart  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Typical Field Wiring (Air Handler / Electrical Heat) . . . . . . . . . . . . . . . .7
CFM Selection Board  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Wiring Diagram  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

LIST OF TABLES

1-1/2 Ton Subcooling Charging Chart  . . . . . . . . . . . . . . . . . . . . . . . . . 8
2 Ton Subcooling Charging Chart   . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2-1/2 Ton Subcooling Charging Chart  . . . . . . . . . . . . . . . . . . . . . . . . . 9
3 Ton Subcooling Charging Chart   . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

3-1/2 Ton Subcooling Charging Chart   . . . . . . . . . . . . . . . . . . . . . . . . .9
4 Ton Subcooling Charging Chart   . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
5 Ton Subcooling Charging Chart   . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
R-22 Saturated Properties   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Содержание CMB SERIES

Страница 1: ...result in minor or moderate injury It is also used to alert against unsafe practices and hazards involving only property dam age INSPECTION As soon as a unit is received it should be inspected for po...

Страница 2: ...tion of a 100 activated alumina suction line filter drier in the suction line is required in addition to the factory installed liquid line drier Operate the system for 10 hours Monitor the suction dri...

Страница 3: ...oft solder The outdoor units have reusable service valves on both the liquid and vapor connections The total system refrigerant charge is retained within the outdoor unit during shipping and installat...

Страница 4: ...System Charge section for checking and recording system charge SECTION IV INSTALLATIONS REQUIRING AN ADD ON TXV KIT For installations requiring a TXV kit refer to the Installation Instructions accomp...

Страница 5: ...at with permagum or equivalent to prevent air drafts affecting the operation of in the thermostat DEHUMIDIFICATION CONTROL A dehumidification control accessory 2HU06700124 may be used with variable sp...

Страница 6: ...0124 PP11C70224 THERMOSTAT THERMOSTAT THERMOSTAT AC5 Thermostat Installer Setup Number 1 System Type must be set to 0 Selection of GAS ELEC switch on thermostat not necessary Clipping Jumper W914 for...

Страница 7: ...Total system charge is determined as follows 1 Determine outdoor unit charge from tabular data sheet 2 Determine indoor coil adjustment from tabular data sheet 3 Calculate the line charge using the ta...

Страница 8: ...he liquid line at the outdoor unit will feel warm to the touch Instructing the Owner Assist owner with processing warranty cards and or online registration Review Owners Guide and provide a copy to th...

Страница 9: ...3 15 286 15 289 15 115 300 15 301 15 304 15 307 15 120 319 14 320 15 323 15 326 14 125 338 14 339 14 342 14 345 14 TABLE 5 3 1 2 Ton Subcooling Charging Chart Outdoor Ambient Indoor Wet Bulb F 57 62 6...

Страница 10: ...112 86 51 116 67 146 81 176 93 206 103 236 113 88 52 118 68 148 82 178 94 208 104 238 114 90 54 120 69 150 83 180 94 210 105 240 114 92 55 122 70 152 84 182 95 212 105 242 115 94 56 124 71 154 84 184...

Страница 11: ...163911 UIM A 0106 Unitary Products Group 11 SECTION IX WIRING DIAGRAM FIGURE 9 Wiring Diagram...

Страница 12: ...to change without notice Printed in U S A 163911 UIM A 0106 Copyright by York International Corp 2006 All rights reserved Supersedes NothingNothing Unitary 5005 Norman Product York OK Group Drive 7306...

Отзывы: