Contact Sensor

(Indoor/Outdoor)

YS7707-UC

Installa on & User Guide

Rev 1.0

Содержание YS7707-UC

Страница 1: ...Contact Sensor Indoor Outdoor YS7707 UC Installa on User Guide Rev 1 0...

Страница 2: ...Contents In the Box 1 Introduc on 2 Set Up 5 Installa on 7 Using the YoLink App 13 About YoLink Control 18 Maintenance 24 Speci ca ons 27 Troubleshoo ng 29 Warning 30 Customer Service Warranty 32...

Страница 3: ...1 In the Box A Contact Sensor with Reed Switch B Magnet C AA Ba ery 2 D Self tapping Screw M3 4 E Double sided Tape F Quick Start Guide B A C F D E...

Страница 4: ...Sensor include dry contact relays non smart door contacts water leak detectors temperature and humidity sensors tamper switches lt alarms contacts swing type doors and gates can lever gates sliding d...

Страница 5: ...AA non rechargeable ba eries Due to the waterproof design the enclosure clamp Latch may be slightly di cult to open Moun ng Slot Use screws to mount the magnet on the wall Moun ng Slot Use screws to...

Страница 6: ...ast Blinking Green Establishing Connec on with YoLink System YoLink Control Slow Blinking Green Upda ng Fast Blinking Red Removing Connec on to YoLink System YoLink Control Blinking Red Once Alert Mod...

Страница 7: ...Google Play Store Log in or create a new account if required Download and log in to YoLink app 1 YoLink Hub is required to set up your Sensor Please set up your YoLink Hub rst Contact refer to YoLink...

Страница 8: ...ne and ready to use Tap bu on then scan QR Code on the device Tap bu on to add devices 1 Press the SET bu on on front of sensor once 2 SET Bu on Status LED will blink red once then green several mes I...

Страница 9: ...to the following steps for informa on on crea ng automa ons then return to this step Be sure the installing gap between sensor and magnet is within 0 7 inch and the magnet is aligned with the interna...

Страница 10: ...window or gate These Tools may be Required Skip to page 1 for 0 monitoring contact closure type devices equipment If you choose to mount the reed switch and magnet using double sided tape you will nee...

Страница 11: ...the double sided tape on the back of the contact sensor Remove the other side of the protec ve layer from the double sided tape on the back of the contact sensor place the contact sensor in the desire...

Страница 12: ...ewdriver Note Your contact closure type device must be func onal and de energized disconnected from other equipment see page 2 for addi onal informa on on compa ble contacts Install the sensor ba erie...

Страница 13: ...remove the insula on on each conductor leaving roughly half an inch of exposed conductor 11 If your device has screw type terminals for wiring connec ons proceed to the next page Otherwise using a wi...

Страница 14: ...es with electrical tape Refer to Install or Replace the Ba eries sec on on page for the installa on of ba eries for the 26 contact sensor Refer to page 9 for sensor installa on instruc on Test the con...

Страница 15: ...Device history Door gate window contact closure output device opened and closed logged with date me Connec on status of sensor and Hub Details Tap to go to Details page refer to page 14 Current Ba er...

Страница 16: ...ou when the door window is le open for a set me Default is set to 20 seconds Add remove from favorites Device history Door window opened and closed logged with date me 14 Device EUI unique Device SN u...

Страница 17: ...Upon the opening or closing or le open for a set me of the door gate window contact closure output device an alert will be sent to your YoLink account Door is opened Door is closed 15 Door is s ll ope...

Страница 18: ...o enable or disable the automa on Click to edit the automa on Swipe le to view the history logs and to edit or delete the automa on 16 Contact Sensor can be set as a trigger only Edit trigger Edit beh...

Страница 19: ...the upper le corner to go to My Pro le Connect YoLink with third party voice assistants service to monitor the status of your devices through voice commands Contact Sensor is integrated with Alexa an...

Страница 20: ...or Water Leak Sensor while examples of a responder are a Siren or a YoLink Plug Mini To co n g u re yo u r O u td o o r C o nta c t S e n s o r a s a co nt ro l l e r rst e n s u re t h e door gate wi...

Страница 21: ...urn o the YoLink Plug when the door is opened Mini If you want to turn on or o the YoLink Plug Mini when the door is closed rst ensure the door gate window is in the closed posi on or the connected co...

Страница 22: ...on the YoLink Plug Mini Turned on for 5 10 seconds until the blue light blinks quickly POWER Bu on Turn on the plug verify the Status LED of YoLink Plug Mini Refer to the YoLink displays blue Plug Mi...

Страница 23: ...ately turn on The plug will remain turned on un l turned o using the POWER bu on or via the app More advanced sequences controlling mul ple outputs e g turn o plug and ac vate siren are available via...

Страница 24: ...will stop blinking and return to the previous color blue for turned on red for turned o At the YoLink Plug Mini responder press and hold the POWER bu on for 10 15 seconds un l the LED quickly blinks b...

Страница 25: ...nds until the red light blinks quickly 1 2 Hold the POWER button on the YoLink Plug Mini for 10 15 seconds until the red light blinks quickly POWER Bu on Plug is either turned on or turned o 23 SET Bu...

Страница 26: ...aximum To force an immediate update press the SET bu on on the device once to make the device enter update mode In Firmware if a new version is listed as available ready now click it to start the rmwa...

Страница 27: ...r device will remain in your Yolink account 25 SET Bu on Factory reset will be complete when the status light stops blinking Hold the SET bu on for 20 25 seconds un l the status light blinks red and g...

Страница 28: ...design this step may be slightly di cult Install two new and then close the alkaline non rechargeable two clamps of the AA ba eries sensor Using the app check the online status of the sensor and verif...

Страница 29: ...h 18 millimeters Voltage 3V DC 2 ies Alkaline Non Rechargeable AA Ba er 27 Reed Switch Type NC Normal closed type IP Ra ng IP63 Waterproof Environment Indoor Outdoor use Temperature 4 F C 122 F 20 50...

Страница 30: ...50 0 1 42 36 0 3 29 83 5 0 89 22 6 0 95 24 1 3 29 83 5 TOP 0 89 22 6 0 95 24 1 1 97 50 0 1 42 36 0 28 Length of Connec on Cable Roughly 13 inches 33 cen meters 1 14 29 0 0 75 19 0 0 75 19 0 1 14 29 0...

Страница 31: ...Hub to the Internet and press the SET bu on on contact sensor once If Hub is not on power on the Hub again and press the SET bu on on contact sensor once If sensor is out of range with Hub reloca ng...

Страница 32: ...me of the sensor installing the sensor with overhead protec on from weather is suggested Do not immerse the sensor or allow it to be immersed in water Do not install or use the sensor where it will be...

Страница 33: ...follow local ba ery disposal procedures To avoid damaging the controller if storing the sensor for an extended period remove the ba eries Please contact Customer Service before a emp ng to repair dis...

Страница 34: ...acement of the contact sensor only at YoSmart s sole discre on YoSmart will NOT be liable for the cost of installing removing nor reinstalling this product nor direct indirect or consequen al damages...

Страница 35: ...can be determined by turning the equipment o and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Connec...

Страница 36: ...pplicable to only Mobile Con gura ons The antennas used for this transmi er must be installed to provide a separa on distance of at least 20 cm from all persons and must not be co located or opera ng...