background image

Max puls

Maximum number of impulses, at exceeding this number of impulses (before reaching
cut value) the tool will shut-off and the tightening will be judged as NOK

1 ~ 70

30

Min puls

Minimum number of impulses, if the tool shuts-off before this number of impulses
(reaching the cut value) are made the tightening will be judges as NOK.

1 ~ 70

2

Slow Error Impulses:

Tool will shut-off after making more than 70 impulses, including those below start value. The tightening will be judged as NOK (Slow error).

YZ-T setting procedure:

Please set the parameters with the PC-1 as below:

Start value : 10
Switch value : 10
Cut Value : 150
Max Value :150
Average: 3
Low speed : 300 rpm
Middle speed: 3000 rpm
High speed: 4800 rpm
Min impulses: 2
Max impulses: 70​

Make a test cycle, be aware the tool will only shut off automatic after the maximum number of 70 impulses, please release the trigger at the moment the socket doesn't rotate anymore.

Torque measuring / checking can be done with a torque wrench or rotary transducer on the actual application. Please make at least 2 cycles and check the torque in the joint before making any
changes in the adjustment or settings.

Please start with the relief valve at minimum setting to prevent damage to the product with a too high torque.
Set the torque higher if needed by the relief valve.
If torque is OK please check the value with PC-1 in Test Mode.
Set the Cut value according the stabilized value found with the test mode.
Adjust the relief valve just a little higher or set the high speed a little higher.
Set the minimum and maximum number of impulses according the hardness of the application.
Set the start value and the switch value according the hardness of the application.

The number of impulses:

In order to get a good quality joint with the correct clamp-force and a good repeatability, a certain number of impulses should be made, this number of impulses depends on the kind of joint
(hard or soft). ​

For a hard joint 6 – 10 impulses and  a soft joint 12 – 40 impulses depending on the softness of the joint.

Changing the speed and or the cut value will have an influence on the number of impulses.

​For Yokota impulse wrenches we advise to do a preventive oil change maintenance after 250.000 cycles. 1 cycle is 0.5 seconds impulsing (hard joint). Oil change is including replacing the service
kit.

Maintenance:

Check the tool regularly for loose bolts/screws or parts.

Measure the rpm of the tool regularly, in case of higher or lower rpm than indicated in the technical specifications: Stop using the tool immediate and have it repaired.

In case of power loss: Have the tool repaired.

Only trained and qualified engineers are allowed to adjust or repair the tool.

The tool should be maintained regularly to minimize the noise emission and occurring vibration.​

The speed can be changed between 4800 rpm and 2000 rpm. Push the button until 2 short beeps and 1 long beep, release the button and the speed is changed.

In the inspection mode parameter can’t be set, rundown history and pulse data will not be stored.

To cancel the inspection mode take off the battery. After replacing the battery the tool is back in normal operation mode.

Buzzer Sound and LED lightning patterns.

Warning LED Pattern.

Содержание YZ-T900E

Страница 1: ...YZ T900E MANUAL EN www rami yokota com...

Страница 2: ...r to our website Make sure that during operation of the tool no projectiles can be generated this can be dangerous and may cause injuries Make sure that the work piece is securely fixed Make sure that...

Страница 3: ...t in short circuit of the terminals of the battery pack and fire Do not expose battery cartridge to water or rain A battery short can cause large current flow overheating possibly burns and even a bre...

Страница 4: ...s too low 10 Value too low 11 Number of impulses too high 12 Cycle OK The torque reached in the joint is depending on 3 settings The motor speed 1 Output value 2 Cut value 3 Tightening time 4 Value ri...

Страница 5: ...s output with the relief valve mechanical adjustment on the impulse mechanism Always take off the battery when adjusting the torque output with the relief valve on the impulse mechanism Use the TF pin...

Страница 6: ...sult setting item and set value 3 Function key Switching of tightening screen setting screen and or of display screen 4 Numeric key Enter the set value 5 CAN key Return to the previous screen 6 ENT ke...

Страница 7: ...arameter or use CAN to cancel the input value Use Up and Down arrow to select the next parameter to be set Press NEXT key to enter the next page of parameters to be set or PREV to previous page By pre...

Страница 8: ...o enter this function Result 20 the average on which the tool has shut off NUM 6 number of impulses including the impulses lower than start value 6 12 15 19 20 21 the value of each impulse If you have...

Страница 9: ...value Switch value Cut value Max value 10 150 10 Switch value Value to switch motor speed from middle speed to high speed Switch value Cut value Max value 10 150 10 Cut value Shut off value as soon as...

Страница 10: ...h speed a little higher Set the minimum and maximum number of impulses according the hardness of the application Set the start value and the switch value according the hardness of the application The...

Страница 11: ...Over voltage Error Over current Error Abnormal pulse signal Memory Error Please send the tool for repair to an authorized service shop Extreme low environment temperature can show a wire breakage erro...

Страница 12: ...pack Overheat alarm 3 Lighting Please wait until release LED lamp lights off 1 Low voltage error may operate when using a battery pack whose performance has deteriorated due to deterioration low temp...

Страница 13: ...of warranty claims is no part of the warranty arrangements Also claims for loss of production and or other damages are excluded from this warranty Repairs under warranty can only be considered when t...

Страница 14: ...www rami yokota com...

Отзывы: